background image

Instructions for Installing the MicroPulse

®

 

SignalMaster

 

with or Without Brake Module

25500452  Rev A2 0821

Safety Message to Installers and Service Personnel of  

Warning Light Equipment

People’s lives depend on your proper installation and servicing of Federal Signal products. It is important 

to read and follow all instructions shipped with this product and the original product. Listed below are 

some other important safety instructions and precautions you should follow:
•  To properly install this light, you must have a good understanding of automotive electrical procedures 

and systems, along with proficiency in the installation and use of safety warning equipment.

•  Always refer to the vehicle’s service manuals when performing equipment installations on a vehicle.
•  Never attempt to install aftermarket equipment that connects to the vehicle wiring without reviewing 

a vehicle wiring diagram available from the vehicle manufacturer. Ensure that your installation will not 

affect vehicle operation or mandated safety functions or circuits. Always check the vehicle for proper 

operation after installation.

•  When drilling into a vehicle structure, ensure that both sides of the surface are clear of anything that 

could be damaged.

•  In order for the light to function properly, a separate ground connection must be made. If practical, it 

should be connected to the fusible link at the front fender between the negative (–) battery terminal 

and chassis ground. At a minimum, it may be attached to a solid metal body or chassis part that will 

provide an effective ground path as long as the light system is to be used. 

•  Locate the light control so the VEHICLE and CONTROL can be operated safely under all driving 

conditions.

•  If a seat is temporarily removed, verify with the vehicle manufacturer if the seat needs to be 

recalibrated for proper airbag deployment.

•  Do not attempt to activate or deactivate the light control while driving in a hazardous situation.
•  This product contains high-intensity LED devices. To prevent permanent eye damage, DO NOT stare 

into the light beam at close range.

•  Frequently inspect the light system to ensure that it is operating properly and that it is securely 

attached to the vehicle.

•  Do not install equipment or route wiring in the deployment path of an airbag. Failure to observe this 

warning will reduce the effectiveness of the airbag or potentially dislodge the equipment, causing 

serious injury to you or others.

•  File these instructions in a safe place and refer to them when maintaining and/or reinstalling    

the product. 

Failure to follow all safety precautions and instructions may result in property damage, serious injury, or 

death to you or others.

Summary of Contents for MicroPulse SignalMaster

Page 1: ...der for the light to function properly a separate ground connection must be made If practical it should be connected to the fusible link at the front fender between the negative battery terminal and chassis ground At a minimum it may be attached to a solid metal body or chassis part that will provide an effective ground path as long as the light system is to be used Locate the light control so the...

Page 2: ... 6 inches 6 6 cm Length 65 2 inches 165 6 cm 50 6 inches 128 5 cm 44 2 inches 112 3 cm 41 8 inches 106 2 cm 36 9 inches 93 7 cm 31 7 inches 80 5 cm and 23 1 inches 58 7 cm Depth 3 4 inches 8 6 cm Cable Length 15 x 30 x 60 feet 457 2 x 914 4 x 1828 8 cm Installing the MicroPulse SignalMaster Light Assembly STATIC SENSITIVE DEVICE The circuitry can be damaged or destroyed by electrostatic discharge ...

Page 3: ...tall the replacement light head by securing it with two removed screws Tighten the screws so that there is no movement in that light head Ensure that the LED is facing the upright position Testing the System LIGHT HAZARD To be an effective warning device this product produces bright light that can be hazardous to your eyesight when viewed at a close range Do not stare directly into this lighting p...

Page 4: ...a soft cloth and a solution of water and a mild detergent CRAZING CHEMICALS Crazed cracked or faded lenses or reflectors reduce the light output and the effectiveness of the lighting system A lens or reflectors showing this type of aging must be replaced Failure to follow this warning may result in bodily injury or death Failure to follow this warning can damage the lenses and reflectors reducing ...

Page 5: ... Service Department Federal Signal Corporation Phone 1 800 433 9132 Email empserviceinfo fedsig com www fedsig com Getting Repair Service The Federal Signal factory provides technical assistance with any problems that cannot be handled locally Any units returned to Federal Signal for service inspection or repair must be accompanied by a Return Material Authorization RMA Obtain an RMA from a local ...

Page 6: ...al Signal Drive University Park IL 60484 3167 Limited Warranty This product is subject to and covered by a limited warranty a copy of which can be found at www fedsig com SSG Warranty A copy of this limited warranty can also be obtained by written request to Federal Signal Corporation 2645 Federal Signal Drive University Park IL 60484 email to info fedsig com or call 1 708 534 3400 ...

Page 7: ...ing but not limited to the warranty of merchantability warranty of fitness for a particular purpose and any warranty against failure of its essential purpose Ordering Replacement Parts To order replacement parts call Customer Support at 1 800 264 3578 7 a m to 5 p m Monday through Friday CT or contact your nearest distributor Table 2 Replacement Parts Description Part Number Red Surface Mount Brak...

Page 8: ...ty Park Illinois 60484 3167 www fedsig com Customer Support Police Fire EMS 800 264 3578 1 708 534 3400 Work Truck 800 824 0254 1 708 534 3400 Technical Support 800 433 9132 1 708 534 3400 Copyright 2018 2021 Federal Signal Corporation ...