Ordering Replacement Parts and Accessories

A replacement part for the driver/PCB assembly and accessories are listed in Tables 2 and 3. Due to certification, certain 

component parts are not available for field replacement. Sounders with this type of damage must be either replaced 

entirely or returned to Federal Signal for service. Refer to instruction manual 25500259 for accessory and replacement 

part assembly and operating instructions. To order, call Federal Signal Customer Support at 708-534-4756 or 877-289-

3246.

 Table 2  Replacement parts

Description 

Part Number

Multi-voltage G-SND Sounder Kit (Includes PCBAs, 

Bracket, Driver, & Mounting Screws)

K859501404

 Table 3  Accessories

Description 

Part Number

Indicator Ring/Legend Kit, Black 

G-KIT-RP-BK

Indicator Ring/Legend Kit, Blue 

G-KIT-RP-B

Indicator Ring/Legend Kit, Green 

G-KIT-RP-G

Indicator Ring/Legend Kit, Magenta 

G-KIT-RP-M

Indicator Ring/Legend Kit, Red 

G-KIT-RP-R

Indicator Ring/Legend Kit, Yellow 

G-KIT-RP-Y

E-Box Endcap with M20 Opening 

K859500805-02

E-Box Endcap with M25 Opening 

K859500805-01

E-Box Cover Assembly (Includes two terminal blocks, 

mounting plate, retention hardware) 

K859501414

In-Line E-Box Coupler Kit 

G-KIT-EC180

90-Degree E-Box Coupler Kit 

G-KIT-EC90

Extension Box Spacer Kit 

G-KIT-EXTB

Single Trunnion Kit 

G-KIT-ST

Dual Trunnion Kit 

G-KIT-DT

Adapter, M20 Male to 1/2" Female NPT 

K231246A

Adapter, M20 Male to 3/4" Female NPT

K231247

15 W Audible Acoustic Insert

G-KIT-15WINSERT

 Table 4  Choosing cable-entry devices for equipment in potentially explosive atmospheres

Models 

Ex Atmospheres Cable Entry Devices 

(cable glands, stopping plugs, etc.

G-SND-XXX-D (Ex db 

surface mount)

Gas

Cable entry devices shall be equipment certified as flameproof. To 

maintain the ingress protection of the flameproof sounder enclosure, we 

recommend the cable entry device be IP66 certified.

G-SND-XXX-E 

Gas

For the flameproof enclosure, cable entry devices shall be equipment 

certified as flameproof. To maintain the ingress protection of the 

flameproof enclosure, we recommend the cable entry device be IP66 

certified. For the increased safety terminal enclosures (terminal boxes), 

cable entry devices shall be equipment certified as increased safety and 

shall maintain an IP rating of IP54.

G-SND-XXX-D (Ex db 

surface mount) 

G-SND-XXX-E (Ex db e 

surface mount)

Dust

Cable entry devices for the and terminal enclosures shall be equipment 

certified as dust protected. To maintain the ingress protection of the 

sounder and terminal enclosures, the cable entry devices shall be IP6X 

certified.

Summary of Contents for G-SND

Page 1: ...e in certain situations permanent hearing loss You should take appropriate precautions such as wearing hearing protection After installation test the sound system to ensure proper operation The purcha...

Page 2: ...arge The metallic brass inserts have a capacitance of 24 pF See the manufacturer s instructions for further information cULus Zone Certifications This equipment is for use in Class I Zone 1 and Zone 2...

Page 3: ...the product is Ex db marked only it is for use in gas atmospheres If the product is Ex db e marked it uses the increased safety terminal enclosures and is only for gas atmospheres If the product is Ex...

Page 4: ...Ex d e Surface Mount Sounder Mount the sounder to a flat surface using the six 8 5 mm mounting holes Use installer supplied fasteners suitable for the surface to which the device will be mounted Figu...

Page 5: ...eassembling the unit Painting and surface finishes other than those applied by Federal Signal Corporation are not permitted Cable termination should be in accordance with specifications applying to th...

Page 6: ...a of the phase conductor Cable termination for these models should be in accordance with specifications applying to the application It is recommended that all cables and cores be fully identified Use...

Page 7: ...Connect the line hot power source wire to the terminal block position marked L1 on the PCB d Connect the neutral common power source wire to the terminal block position marked L2 on the PCB e Connect...

Page 8: ...osition marked L2 on the PCB d Connect the positive power source wire to the terminal block position marked L1 on the PCB e Connect the ground wire to the terminal block position marked EARTH f Connec...

Page 9: ...1 s Factory setting Preparing to Wire the Ex de Increased Safety Models SHOCK HAZARD To avoid electrical shock hazards do not connect wires when power is applied Failure to observe this warning may l...

Page 10: ...r side of any terminal must be joined in a suitable manner e g two conductors into a single insulated crimped bootlace ferrule 3 To connect wires press the button on the terminal block with a Phillips...

Page 11: ...y two tones are remotely selectable on Ex de 120 Vac units 24 Vdc operation remote switching of tones with remote power a Connect the negative power source wire to the position marked L2 on the termin...

Page 12: ...hat the nameplate remains readable After performing any maintenance test the sounder system to ensure that it is operating properly Failure to follow all safety precautions and instructions may result...

Page 13: ...14 In Line E Box Coupler Kit G KIT EC180 90 Degree E Box Coupler Kit G KIT EC90 Extension Box Spacer Kit G KIT EXTB Single Trunnion Kit G KIT ST Dual Trunnion Kit G KIT DT Adapter M20 Male to 1 2 Fema...

Page 14: ...ltage Vdc 16 Vdc to 33 Vdc NOTE UL evaluated this product only to the stated operational voltage range It was not evaluated to 80 to 110 of the voltage range The sounder is factory set with the tone s...

Page 15: ...echnical Assistance Contact our Technical Support Team at 1 708 587 3587 or signalsupport fedsig com Repair Service A return authorization is required Contact your Authorized Distributor or Federal Si...

Page 16: ...dicionales disponibles en signaling fedsig com Customer Support 1 800 344 4634 1 708 534 4756 iordersup fedsig com Technical Support 1 800 755 7621 1 708 587 3587 signalsupport fedsig com signaling fe...

Reviews: