Safety Messages to Installers and Users 

Product should be installed by a licensed electrician and 

follow all safety instructions. Failure to do so may result in property damage, serious injury, or death. 
•  To avoid electrical shock hazards, do not connect wires when power is applied.
•  To be an effective warning device, this product produces bright light that could be hazardous to eyesight. 

Do not stare directly at the light. Rapid flashing could induce photosensitive epilepsy.

•  Never alter the unit in any manner. Safety in hazardous locations may be endangered if additional 

openings or alternations are made.

•  WARNING - EXPLOSION HAZARD:  Do not disconnect the equipment unless power has been switched 

off or the area is known to be non-hazardous. To reduce the risk of ignition due to electrostatic discharge, 

avoid contact with the unit while an explosive atmosphere is present. Clean only with a damp cloth. Do 

not use chemical cleaners.

Overview:

 FB2LEDX Series can be programmed to produce one 

of three light patterns: steady, 60 FPM, and 120 FPM (preset to 

60 FPM). Units are available in 12-24VDC or 120-240VAC.

Certifications and Ratings:

•  Model FB2LEDX is UL and cUL Listed for Class I,  

Division 2, Groups A, B, C and D (T5); Class II, Division 

2, Groups F and G (T6); Class III (T6); or non-hazardous 

locations only 

•  Model FB2LEDX-CN is UL and cUL Listed for Class I, Zone 2 

(T5); Class II, Zone 22 (T85); or non-hazardous locations only 

•  Type 4X, IP66
•  IP69K Compliant
•  Electrical ratings: 0.48A - 0.24A (12-24VDC) or 0.03A (120-240VAC 50/60HZ)
•  Certified Operating Temperature: -40°F to 150°F (-40°C to 66°C)
Unpacking the Device: 

After unpacking the device, examine it for damage and verify parts. Unit comes 

with: (1) FB2LEDX assembled unit with guard, flying leads and (1) panel mount gasket, (3) No. 8 x 1/2" panel 

mounting tapping screws. If a part is missing or damaged do not attempt to install. Contact Federal Signal 

Customer Support at +1 708-534-4756 or [email protected]
Mounting the Device: 

FB2LEDX units come standard to mount on a flat (horizontal or vertical) surface or on 

a 1/2" NPT threaded pipe. Wall mounting bracket (LHWB) accessory is sold separately.
•  Warning - Explosion Hazard – 

To reduce the risk of fire or explosion, do not install the unit in a 

hazardous location if the operating temperature exceeds the atmosphere’s ignition temperature. Consult 

product nameplate to determine the temperature code of the unit.

•  Pipe Mounting – 

FB2LEDX Series can be pipe mounted on a 1/2" NPT pipe. Feed wires through pipe and 

turn clockwise to tighten. Recommended tightening torque is 5-ft-lbs (6.8 N-m).

•  Surface/Panel Mounting – 

Using provided gasket as a template, mark three mounting holes and center 

hole for wiring. Drill or punch 0.188" (5.0mm) diameter holes for mounting and a .88" (22.0mm) for wiring. 

Set base on gasket, feed wires through center hole, and attach to the mounting surface using provided 

No. 8 tapping screws from the underside.

Installation and Maintenance Instructions

4.80" / 121.79 mm

5.76" / 146.37 mm

LED PCBA

1/2" NPT Pipe Mount

and 3-hole Surface Mount

Impact-Resistant

Fresnel Dome

Black Stainless

Steel Wire Guard

Summary of Contents for Fireball FB2LEDX Series

Page 1: ...Class II Zone 22 T85 or non hazardous locations only Type 4X IP66 IP69K Compliant Electrical ratings 0 48A 0 24A 12 24VDC or 0 03A 120 240VAC 50 60HZ Certified Operating Temperature 40 F to 150 F 40 C to 66 C Unpacking the Device After unpacking the device examine it for damage and verify parts Unit comes with 1 FB2LEDX assembled unit with guard flying leads and 1 panel mount gasket 3 No 8 x 1 2 p...

Page 2: ...de copy of these instructions to all operating personnel Ordering Replacement Parts and Accessories If your unit requires a part not listed below it must be replaced or repaired Description Part Number PCBA 24VDC Amber Red Green K20000401A PCBA 24VDC Clear Blue K20000401A 01 PCBA 120 240VAC Amber Red Green K20000426A PCBA 120 240VAC Clear Blue K20000426A 01 Wire Guard FB2G Wall Mounting Bracket As...

Page 3: ...digo T T6 o ubicaciones no peligrosas solamente Gabinete Tipo 4X IP66 El modelo FB2LEDX CN tiene certificación UL y cUL para Clase I Zona 2 T5 Clase II zona 22 T85 o ubicaciones no peligrosas solamente Clasificaciones eléctricas 0 48 A 0 24 A 12 24 VCC o 0 03 A 120 240 VCA 50 60 Hz Adecuado para uso en interiores o exteriores Cumple con IP69K Temperatura de funcionamiento certificada 40 F a 150 F ...

Page 4: ...durante más de 5 segundos Prueba Funcionamiento Después de la instalación pruebe el sistema para verificar que cada señal funcione y establezca un programa para pruebas periódicas del dispositivo Entregue una copia de estas instrucciones a todo el personal de operación Pedido de piezas de repuesto y accesorios Si su unidad requiere una pieza que no se enumera a continuación debe ser reemplazada o ...

Page 5: ...eux uniquement Le modèle FB2LEDX CN est homologué UL et cUL pour la classe I zone 2 T5 Classe II zone 22 T85 ou emplacements non dangereux uniquement Coffret type 4X IP66 Valeurs électriques 0 48 A 0 24 A 12 24 V CC ou 0 03 A 120 240 V CA 50 60 Hz Conforme à la norme IP69K Température de fonctionnement certifiée 40 C à 66 C 40 F à 150 F Déballage de l appareil Après avoir déballé l appareil examin...

Page 6: ... l appareil pendant plus de 5 secondes Tests fonctionnement Après l installation testez le système pour vérifier le fonctionnement de chaque signal et établissez un programme de test périodique de l appareil Fournissez une copie de ces instructions à tout le personnel de service Commande de pièces de rechange et d accessoires Si votre appareil nécessite une pièce qui ne figure pas dans la liste ci...

Reviews: