Table 2 SPL and Current Data: DC Model 55/56 Horn Tone
55/56 Horn Tone (330.0 Hz Steady)
LEVEL
TAPS
SPL
DC Current (A)
WIRE 1
WIRE 2
(dBA @ 10 ft)
24 Vdc
High
P1
P5
117
3.3
Med
P1
P3
106
0.5
Low
P2
P3
96
0.24
NOTICE:
Apply wires only to the positions designated in Table 2. Other
variations could cause damage to the eHorn.
Table 3 SPL and Current Data: AC Model 52 Horn Tone
52 Horn Tone (315.6 Hz Steady)
LEVEL
TAPS
SPL
AC Current (A)
WIRE 1
WIRE 2
(dBA @ 10 ft)
120 Vac
240 Vac
High
P2
P4
114
0.78
0.40
Med
P1
P3
111
0.35
0.16
Low
P2
P3
101
0.15
0.03
NOTICE:
Apply wires only to the positions designated in Table 3. Other
variations could cause damage to the eHorn.
Table 4 SPL and Current Data: AC Model 55/56 Horn Tone
55/56 Horn Tone (330.0 Hz Steady)
LEVEL
TAPS
SPL
AC Current (A)
WIRE 1
WIRE 2
(dBA @ 10 ft)
120 Vac
240 Vac
High
P3
P5
116
0.76
0.41
Med
P1
P3
107
0.16
0.08
Low
P2
P3
98
0.10
0.06
NOTICE:
Apply wires only to the positions designated in Table 4. Other
variations could cause damage to the eHorn.
Mounting the eHorn
The eHorn can be mounted on any relatively flat surface with or
without the supplied mounting brackets The mounting surface
must be capable of supporting the weight of the eHorn. Four
installer‑supplied 1/4 in screws are required. Use screws that are
suitable for the mounting surface.