Before drilling holes in ANY part of a vehicle, be 

sure that both sides of the mounting surface are 

clear of parts that could be damaged: such as brake 

lines, fuel lines, electrical wiring or other vital 

parts.

 

3.  Use the assembled unit as a template, adjust as 

necessary, and scribe mounting hole position marks on the 

mounting surface.

 

4.  Drill mounting holes at the previously scribed 

position marks.

 

5.  If required, locate and drill an appropriate hole for 

routing the 13-conductor cable and connector to the Lamp 

&Relay/Interface unit.

E.  ELECTRICAL SPECIFICATIONS.

 

This unit is intended to operate on a 12.8 VDC, nega-

tive ground system.  This unit is designed to operate in 

conjunction with Federal Signal SignalMaster controllers 

330102, 330103, 331102, and SmartSiren® models with 

SignalMaster control.

F.  TESTING.

 

This product contains high output LED 

devices.  To prevent eye damage, do not stare 

into the light beam at close range.

 

After installation is complete, check the entire system 

for proper operation and ensure that all siren/light system 

functions are operating properly.

Figure 1.

SAFETY MESSAGE TO OPERATORS

 

The lives of people depend on your safe 

operation of Federal Signal Products.  It is 

important to read and follow all instructions 

shipped with the products.  In addition, listed 

below are some other important safety in-

structions and precautions you should follow:
•  Although your warning system is operat-

ing properly, it may not be completely effec-

tive.  People may not see or heed your warn-

ing signal.  You must recognize this fact and 

continue driving cautiously.
•  Also, situations may occur which obstruct 

your warning signal when natural or man-

made objects are between your vehicle and 

others, such as: raising your hood or trunk 

lid.  If these situations occur, be especially 

careful.
•  This product contains high intensity LED 

devices.  To prevent eye damage, DO NOT 

stare into the light beam at close range.
•  At the start of your shift, you should 

ensure that the light is securely attached and 

operating properly.

RETAIN AND REFER TO THIS MESSAGE

G.  MAINTENANCE.

 

1. 

General.

 

Crazing (cracking) of lenses will cause 

reduced effectiveness of the light.  Do not 

use cleaning agents (which will cause craz-

ing) such as strong detergents, solvents, or 

petroleum products.  If crazing of lenses does 

occur, reliability of light for emergency sig-

naling purposes may be reduced until lenses 

are replaced.

 

 

Ordinary cleaning of the plastic lenses can be ac-

complished by using mild soap and a soft rag.  Should fine 

scratches or a haze appear on a lens, they can ordinarily be 

removed with a non-abrasive, high quality, one-step, auto-

motive paste cleaner/wax and a soft cloth.

 

2. 

Replacement Parts.

 

 

The unit must not be opened under any circum-

stance. Failure to adhere to this may result in moisture 

entering the unit causing premature failure. Please contact 

the factory if the unit is not functioning properly.
 

 

Manufactured by:

 

 

Federal Signal Corporation

 

 

Emergency Products Group

 

 

2645 Federal Signal Drive

 

 

University Park, Illinois  60466

 

 

1-800-433-9132

 

 

Email: [email protected]

Copyright 2006 Federal Signal Corporation

-2-

290A5601

SWIVEL

BRACKET

MOUNTING BRACKET

W/PEM ASSEMBLY

EXTENSION BRACKET

1/4" EXTERNAL
TOOTH
LOCKWASHERS

1/4" EXTERNAL TOOTH

LOCKWASHERS

1/4-20 KEPS NUTS

1/4-20 x 7/16" HEX
HEAD SCREWS

1/4-20 x 7/16" HEX

HEAD SCREWS

5/8" TYPE B HEX
HEAD SCREWS

Reviews: