Federal Signal Corporation CUDA TRIOPTIC 351011 Series Instruction Sheet Download Page 2

Figure 1.

290A4680

BOTTOM DRAINAGE

HOLES

LEFT SIDE CABLE ENTRY
(AS SUPPLIED)

CUDAMOD1 LIGHT
HEAD ASSEMBLY

installer for cable entry in the right side, the left rear, or the
right rear. Vertically mounted units may have the cable routed
from the side end cap (as supplied) or from the rear (installer
modified). From a horizontal orientation, the top, bottom and
rear surfaces of the unit are available for mounting. The top
and bottom surfaces have one mounting bolt channel and the
rear surface has two mounting bolt channels (see figure 2).
Choose the mounting channel that best suits your application.

After determining the cable entry and mounting orienta-

tion, follow the appropriate instructions.

1.

Horizontal Mount-Left Side End Cap Cable Entry,
or Vertical Mount-End Cap Cable Entry (unit as
supplied).

See figure 2. Remove the end cap and gasket from the

side of the unit without the power cable. Slide in the two #8-32
x 1/2" hex head machine screws into the channel desired.
Replace the gasket and end cap using the two flat head screws.

Figure 2.

GASKET

290A4681

TOP CHANNEL

REAR CHANNEL

BOTTOM

CHANNEL

SCREWS, #8-32 x 1/2"

HEX HEAD MACHINE (2)

SLIDE MACHINE SCREWS

INTO DESIRED CHANNEL

END CAP

Insure the end cap screws are properly tightened for a tight
seal.

2.

Horizontal Mount-Left Rear Cable Entry, or
Vertical Mount-Rear Cable Entry (installer
modified).

See figure 3. Remove the end cap and gasket from the

side of the unit with the power cable. Remove the end cap and
gasket from end of the grommet/cabling. Remove the left rear
plug from the housing and install it into the removed end cap.
Route the cabling towards the left rear of the unit sliding the
grommet into the slot where the plug was installed. Before re-
attaching the end cap/gasket, slide in the two #8-32 x 1/2" hex
head machine screws into the desired mounting channel.
Replace the gasket and end cap using the two flat head screws.
Insure the end cap screws are properly tightened for a tight
seal.

3.

Horizontal Mount-Right Side End Cap Cable
Entry (installer modified).

See figure 4. Remove the #8-32 screws and lock

washers from the rear of the unit. Remove the screws which
secure the end caps and gaskets in place. Remove both the
right and left plugs from the unit. Slowly slide the left side
cable/end cap/gasket/circuit board assembly out of the housing.
Slide the assembly into the opposite side of the unit. Install the
#8-32 screws/lock washers to lock the assembly into the
housing. Before replacing the end cap/gaskets, slide in the two
#8-32 x 1/2" hex head machine screws into the desired mount-
ing channel. Install the two plugs in the rear of the housing.
Replace the gaskets and end caps using the four flat head
screws. Insure the end cap screws are properly tightened for a
tight seal at both ends.

4.

Horizontal Mount-Right Rear Cable Entry
(installer modified).

Remove the #8-32 screws and lock washers from the

rear of the unit. Remove the screws which secure the end caps
and gaskets in place. Remove both the right and left rear plugs
from the unit. Slowly slide the left side cable/end cap/gasket/

Figure 3.

GASKET

290A4682

TOP CHANNEL

LEFT REAR
PLUG

LEFT REAR

PLUG

ROUTE CABLE /GROMMET

REMOVED FROM END CAP

TO LEFT REAR OF UNIT.

SCREWS, #8-32 x 1/2"

HEX HEAD MACHINE (2)

SLIDE MACHINE SCREWS

INTO DESIRED CHANNEL

END CAP

FLAT HEAD

SCREWS

GROMMET

GROMMET

-2-

Reviews: