![Federal Signal Corporation 2001-AC Description, Specifications, Installation, Operation, And Service Manual Download Page 11](http://html.mh-extra.com/html/federal-signal-corporation/2001-ac/2001-ac_description-specifications-installation-operation-and-service-manual_548513011.webp)
11
Installation
Description, Specifications, Installation, Operation, and Service Manual
Federal Signal
www.fedsig.com
Table 7 2001TRBP Contents
Description
2001TRBP
includes
2001TRBP
Service
Part Number
Transformer rectifier 120246F
Q120246F
48 Vdc Contactor
131A182C
Q131A182C
Fused wire
1461132A
Snubber
20000216
Pan Head screw (2)
7011A069-08
Brass washer
70700520
2 position buss bar
8402109A
Buss bar rt angle
8402138A
Diode Rectifier
115336A
Q115336A
Installation
ELECTROCUTION HAZARD: Electrocution or severe personal injury can occur
when making electrical connections, drilling holes, or lifting equipment. Therefore,
experienced electricians, per national and local electrical codes, acting under the
direction of the installation crew safety foreman, should perform the installation.
Locating the Transformer
Mount the transformer assembly as close as possible to the control unit to keep cabling
distances as short as possible.
See "Table 4 Physical" on page 10 for the size and weight of the various components.
Ensure that the mounting surface and fasteners can safely sustain the weight.
INSTALLATION PRECAUTIONS: The 2001TRBP transformer must be permanently
mounted. All wiring must be run in a sealed conduit. The transformer may become
hot during extended use and should be installed so that it is not likely to be
contacted by people.