SPECIFICATIONS
2-1. MODEL
2
.
Power Requirements ...................................................................... 120Vac/dc, single-phase 24A. or
240Vac/dc, single-phase 12A.
Physical
Diameter ........................................................................... 18" (46 cm)
Height ............................................................................. 25.5" (65 cm)
Shipping Weight. .............................................................. 85 lb. (36 kg.)
Miscellaneous
Sound Output .................................................................... 102dBC at 100 ft.
(30.5m - Model 2)
Motor Type ....................................................................... Single phase ball bearing, universal
series 120Vac/dc, or single phase ball
bearing universal series 240V ac /dc
Power ............ ............................................................................. 2 HP
Top Frequency
Single Tone ...................................................................... 533Hz (60Hz) or 444Hz (50Hz)
Operating Temperature .................................................................. -30° C to 65° C