95% AFUE, ALL-POSITION, TWO-STAGE, VARIABLE SPEED GAS FURNACE
Model Number
FV95A0543A
FV95A0723A
FV95A0905A
FV95A1085A
Position
All-Position
All-Position
All-Position
All-Position
Electrical Characteristics
Volts
120
120
120
120
Hertz
60
60
60
60
Phase
1
1
1
1
Operating Voltage Range (Min-Max)
102 - 132
102 - 132
102 - 132
102 - 132
Max Fuse or CKT Breakers (Amps)
15
15
15
15
Minimum Wire Size
14
14
14
14
Performance Data -
Input BTUH
Low
35,100
46,800
58,500
70,200
High
54,000
72,000
90,000
108,000
Performance - Cooling Data
Furnace Cooling Category (Tons)
1.5 - 3
1.5 - 3.5
2.5 - 5
2.5 - 5
AFUE%
Direct Vent (2 pipe)
Upflow
95
95
95
95
Direct Vent (2 pipe)
Horizontal / Downflow
94
94
94
94
Min. Output Capacity
Direct Vent (2 pipe) - Low
Upflow
33,345
44,460
55,575
66,690
Direct Vent (2 pipe) - Low
Horizontal / Downflow
32,994
43,992
54,990
65,988
Direct Vent (2 pipe) - High
Upflow
51,300
68,400
85,500
102,600
Direct Vent (2 pipe) - High
Horizontal / Downflow
50,760
67,680
84,600
101,520
Certified Temperature Rise
Temperature Rise (°F )
Low
35 - 65
35 - 65
35 - 65
35 - 65
Temperature Rise (°F )
High
35 - 65
35 - 65
35 - 65
35 - 65
Airflow at 0.5" Static
Airflow CFM Approx
Low Heating
∆
T 50°F
618
823
1,029
1,235
Airflow CFM Approx
High Heating
∆
T 50°F
950
1,267
1,583
1,900
Airflow
Cooling Max
1,200
1,400
1,800
1,900
Component Data
Blower Information
Blower Diameter & Width (Inches)
11 x 7
11 x 7
11 x 10
11 x 10
Variable Speed Motor
3/4 hp - ECM
3/4 hp - ECM
1 hp - ECM
3/4 hp - ECM
Motor Speed
Variable
Variable
Variable
Variable
Motor Full Load Amps
7.7
9.6
12.8
9.6
Inducer Draft Blower
Type
2-Speed
2-Speed
2-Speed
2-Speed
Product Specifications
2
Specifications subject to change without notice.