Fedders C1018BBD Installation, Operation And Maintenance Manual Download Page 2

2

CONSUMER INFORMATION

Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Operation and Maintenance Instructions . . . . . . . . . . . . .3

DEALER INSTALLATION

Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Condensing Unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Evaporator & Condensate Drain  . . . . . . . . . . . . . . . . . . .4

Suction & Liquid Lines  . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Replacement Application  . . . . . . . . . . . . . . . . . . . . . . . . .5

Electrical Hook-Up  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Field Charging Procedures  . . . . . . . . . . . . . . . . . . . . .6, 7

Air Handler & Evaporator Match-ups . . . . . . . . . . . . . . . .8

To Install Piston  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

TABLE OF CONTENTS

SERIES NOMENCLATURE

NOMINAL

CAPACITY

24

UNIT

EFFICIENCY

12

CHASSIS

B

B

X

BRAND

X –  V

1 = 230/208 VOLT, 1 PHASE, 60 Hz
2 = 220/240 VOLT, 1 PHASE, 50 Hz
3 = 230/208 VOLT, 3 PHASE, 60 Hz
4 = 460 VOLT, 3 PHASE, 60 Hz
5 = 230 VOLT, 3 PHASE, 50 Hz
6 = 380 VOLT, 3 PHASE, 50 Hz

D

OPTION LEVEL

D = STANDARD UNIT R-22
E = STANDARD UNIT R-407
F = HIGH & LOW PRESSURE SWITCH

REMOTE

CONDENSER

AIR CONDITIONER

C

MODEL

VERSION

V = VALVE SWEAT TYPE FITTING

CONDENSING UNIT

NOMENCLATURE

CONGRATULATIONS

You have made a major investment in a fine piece of equipment. Keep
your investment sound by reading these instructions before installing
this unit. This will ensure that the full potential of this equipment is
achieved. It will also be helpful in avoiding any needless service costs
or operational problems. Included in these instructions are safety
rules, installation, operation, and maintenance instructions.

Only the highest quality components were used in the construction of
your unit. With proper maintenance, your system should provide years
of economical, trouble-free service. 

INSPECTION AND UNPACKING

A thorough inspection of the shipping container should be made
immediately upon receiving your unit. Look for any punctures or
openings, and if it appears damage has occurred, it should be noted
on the freight bill before signing. The delivering carrier should be
contacted immediately to inspect damage, and no installation work
should begin until this inspection is completed.

NOTES TO INSTALLER

The words “SHALL” and “MUST” indicate a requirement which is
essential to satisfactory and safe product performance. The words
“SHOULD” and “MAY” indicate a recommendation or advice which
is not essential and not required but which may be useful or helpful.

The instructions are for the use of qualified individuals specially
trained and experienced in the installation of this type of equipment
and related system components.

Installation and service personnel are required by some locales to
be licensed. Persons not qualified SHALL NOT install this
equipment nor interpret these instructions.

This installation and maintenance manual is provided to ensure the
proper installation and the most satisfactory performance of your
equipment. The instructions contained herein SHALL NOT be
deemed to extend, modify, alter or expand any of the
representations contained in the limited warranty.

WARNING: 

IMPROPER INSTALLATION MAY

DAMAGE EQUIPMENT, CAN CREATE A HAZARD, AND
WILL VOID THE WARRANTY.

!

DANGER:

BEFORE PERFORMING ANY WORK ON

THIS EQUIPMENT, POWER SUPPLY MUST BE
TURNED OFF AT THE HOUSEHOLD SERVICE BOX TO

AVOID THE POSSIBILITY OF SHOCK, INJURY, DEATH OR
DAMAGE TO EQUIPMENT.

!

A

24 B

1

MODEL
SERIES

DESIGN

SERIES

NOMINAL

BTUH

EVAPORATOR

DESIGNATION

E = Matched System Coil
 I  = Mixed System Coil

Nominal Capacity

Slab Code

Coil Type:

A = "A" Coil
P = Plenum Coil

Expansion Device:  Two Digits = Flowrator Piston Size

E4 = Non-Bleed Type TXV 3.5 - 5 Ton
E6 = Non-Adjustable TXV, 1.5 - 3 Ton,
        Matched System E-Coil
E8 = Non-Adjustable TXV, 3.5 - 5 Ton,
        Matched System E-Coil

E   36   12   A   68   S   R   16   M1   0   X

Branding Designation

Housing Color Designation

0 = No Color;  1 = Color

Housing Designation

  i.e., M7, 72, M6, 12    (Non-Housed Coils = XX)

Drain Pan Width:  13", 15", 16", 18", 20", 21", or 23"

Manifold Position: R = Residential (Right Side)

L = Residential (Left Side)
M = Mobile Home

Connection Type: K = Mobile w/Plate Kit Option

S = Sweat

COIL NOMENCLATURE

AIR HANDLER NOMENCLATURE

Summary of Contents for C1018BBD

Page 1: ...REV 9 22 04 23 23 0418N 003 Installation Operation and Maintenance MODEL C10 C12 SERIES 1 5 THRU 5 TON Split System High Efficiency Air Conditioner...

Page 2: ...is inspection is completed NOTES TO INSTALLER The words SHALL and MUST indicate a requirement which is essential to satisfactory and safe product performance The words SHOULD and MAY indicate a recomm...

Page 3: ...vaporator Consider the following factors 1 The air inlet SHALL be located at least 12 from a wall or other obstruction for unrestricted air flow 2 The air outlet SHALL be located so as to direct disch...

Page 4: ...sweat type copper connecting fittings COPPER SUCTION LIQUID LINES 1 Remove the valve core from the schrader port Wrap a wet rag around the copper stub Flux the joint and braze with silphos rod contai...

Page 5: ...ED BY A QUALIFIED LICENSED ELECTRICIAN IMPROPER ELECTRICAL HOOK UP MAY DAMAGE EQUIPMENT CAN CREATE A HAZARD CAUSE PERSONAL INJURY OR DEATH AND WILL VOID THE WARRANTY 5 When replacing an existing syste...

Page 6: ...occurs on the 12 F 6 7 C superheat line ADD CHARGE to obtain 12 F 6 7 C superheat INSTRUCTIONS 1 Measure suction pressure and determine evaporator refrigerant temperature on R 22 scale of low side gau...

Page 7: ...1 115 C F LINE LIMIT DO NOT ADD CHARGE IF POINT FALLS BELOW THIS LINE Chart based on 350 to 400 CFM ton indoor airflow and 50 relative humidity use on systems that cool with fixed restrictor OUTDOOR T...

Page 8: ...ARIATION FROM CHART FOR 3 8 AND 11 8 LINE SET CONDENSER MODEL NUMBER AIR HANDLER MODEL NUMBER COIL MODEL NUMBER Included with Air Handler Depending on match ups the indoor piston may need to be change...