Fedders AC1A024A Installation, Operation And Maintenance Manual Download Page 6

6

14 = 14.5” Casing Width
16 = 16” Casing Width
17 = 17.5” Casing Width
20 = 20.5” Casing Width
22 = 22” Casing Width

C

A = First Revision

Major Revision

024 = 18,000/24000 BTU/H [5.28/7.03 kW]
030 = 30,000 BTU/H [8.79 kW]
036 = 36,000 BTU/H [10.55 kW]
042 = 42,000 BTU/H [12.31 kW]
060 = 60,000 BTU/H [17.5 kW]

Nominal Capacity

C = Cased Coil
S = Slab Coil

Case Designation

1 = Upflow/Downflow

Position

A = A Series

Design Series

A C 1 A

036 A 14

A = Fedders Coil

Brand Coil

14 = 14.5” Casing Width
16 = 16” Casing Width
17 = 17.5” Casing Width
20 = 20.5” Casing Width
22 = 22” Casing Width

Casing Width

A = First Revision

Major Revision

024 = 18,000/24,000 BTU/H [5.28/7.03 kW]
030 = 30,000 BTU/H [8.79 kW]
036 = 36,000 BTU/H [10.55 kW]
042 = 42,000 BTU/H [12.31 kW]
060 = 60,000 BTU/H [17.5 kW]

Nominal Capacity

C = Cased Coil

Case Designation

1 = Upflow/Downflow

Position

A = A Series

Design Series

COIL NOMENCLATURE

MODEL

INDOOR 

CASED COILS

FLUSH FIT TO

FURNACE WIDTH

DESIGN CFM

RANGE

LINE CONNECTIONS O.D.

SUCTION

LINE

LIQUID LINE

AC1A024A

14.5, 16

600 - 900

3/8 

3/4

AC1A030A

14.5, 16, 17.5, 20.5

800 - 1,250

3/8

7/8

AC1A036A

14.5, 16, 17.5, 20.5

1,000 - 1,400

3/8

7/8

AC1A042A

17.5, 20.5

1,300 - 1,500

3/8

7/8

AC1A060A

20.5, 22

1,400 - 1,900

3/8

7/8

CASED COIL DIMENSIONS

SPECIFICATIONS

Model Number Width Height Depth

AC1A024A14

14.5”

20.0”

21”

AC1A030A14

14.5”

20.0”

21”

AC1A036A14

14.5”

20.5”

21”

AC1A024A16

16”

18.5”

21”

AC1A030A16

16”

18.5”

21”

AC1A036A16

16”

18.5”

21”

AC1A030A17

17.5”

18.5”

21”

AC1A036A17

17.5”

18.5”

21”

AC1A042A17

17.5”

23.5”

21”

AC1A060A17

17.5”

22.5”

24”

AC1A030A20

20.5”

18.5”

21”

AC1A036A20

20.5”

18.5”

21”

AC1A042A20

20.5”

22.5”

21”

AC1A060A20

20.5”

22.5”

24”

AC1A060A22

22”

22.5”

24”

Summary of Contents for AC1A024A

Page 1: ...nd Field Installed Expansion Valves 3 Condensate Drain Plumbing 4 Heater Exchange Clearance 4 CHECK AND ADJUST AIRFLOW 5 Static Pressure Drop Chart 5 Adjusting Airflow 5 COIL NOMENCLATURE 6 SPECIFICAT...

Page 2: ...rvice personnel are required by some locales to be licensed Persons not qualified SHALL NOT install this equipment nor interpret these instructions This installation and maintenance manual is provided...

Page 3: ...rs furnaces the same width 1 Set coil on upflow furnace discharge air opening 2 Ensure coil is level for proper condensate drainage Do not tip coil toward condensate drain 3 When installing wider coil...

Page 4: ...AL IS REQUIRED 2 MINIMUM 3 MINIMUM Install condensate drain trap as close to the coil as possible Use drain connection size or larger Do not operate unit without trap see illustration below Unit must...

Page 5: ...gauge reading is below the required pressure increase blower speed until reading is the same or slightly above the required pressure If the gauge reading is above required pressure decrease the blowe...

Page 6: ...kW 060 60 000 BTU H 17 5 kW Nominal Capacity C Cased Coil Case Designation 1 Upflow Downflow Position A A Series Design Series COIL NOMENCLATURE MODEL INDOOR CASED COILS FLUSH FIT TO FURNACE WIDTH DE...

Page 7: ...ship WARRANTY LIMITATIONS Limited Warranty does not include allowances for labor or travel expense connected with the installation of parts so furnished in this Limited Warranty or for field repair or...

Page 8: ...ons cover the general appearance of the units at the time of publication and the manufacturer reserves the right to make changes in design and construction at any time without notice For replacement p...

Reviews: