Installation, Operation and Maintenance

Cased Evaporator Coils

Upflow/Downflow

RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS ................2

NOTES TO INSTALLER ....................................................................2

INTRODUCTION ..............................................................................3

INSPECTION AND UNPACKING ......................................................3

INSTALLATION

Codes..................................................................................2
Installation of Evaporator Coils........................................3
Connect Refrigerant Piping ..............................................3
Factory and Field Installed Expansion Valves ..................3
Condensate Drain Plumbing ............................................4

Heater Exchange Clearance..............................................4

CHECK AND ADJUST AIRFLOW  ....................................................5

Static Pressure Drop Chart ................................................5

Adjusting Airflow ..............................................................5

COIL NOMENCLATURE ..................................................................6

SPECIFICATIONS..............................................................................6

DIMENSIONS ..................................................................................6

WARRANTY ....................................................................................7

NOTE: 

THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED
SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT
AND OPERATION OF THIS EQUIPMENT. READ THE ENTIRE
INSTRUCTION MANUAL THOROUGHLY BEFORE ATTEMPTING
INSTALLATION OR OPERATION.

TABLE OF CONTENTS

 

Summary of Contents for AC1A024A

Page 1: ...nd Field Installed Expansion Valves 3 Condensate Drain Plumbing 4 Heater Exchange Clearance 4 CHECK AND ADJUST AIRFLOW 5 Static Pressure Drop Chart 5 Adjusting Airflow 5 COIL NOMENCLATURE 6 SPECIFICAT...

Page 2: ...rvice personnel are required by some locales to be licensed Persons not qualified SHALL NOT install this equipment nor interpret these instructions This installation and maintenance manual is provided...

Page 3: ...rs furnaces the same width 1 Set coil on upflow furnace discharge air opening 2 Ensure coil is level for proper condensate drainage Do not tip coil toward condensate drain 3 When installing wider coil...

Page 4: ...AL IS REQUIRED 2 MINIMUM 3 MINIMUM Install condensate drain trap as close to the coil as possible Use drain connection size or larger Do not operate unit without trap see illustration below Unit must...

Page 5: ...gauge reading is below the required pressure increase blower speed until reading is the same or slightly above the required pressure If the gauge reading is above required pressure decrease the blowe...

Page 6: ...kW 060 60 000 BTU H 17 5 kW Nominal Capacity C Cased Coil Case Designation 1 Upflow Downflow Position A A Series Design Series COIL NOMENCLATURE MODEL INDOOR CASED COILS FLUSH FIT TO FURNACE WIDTH DE...

Page 7: ...ship WARRANTY LIMITATIONS Limited Warranty does not include allowances for labor or travel expense connected with the installation of parts so furnished in this Limited Warranty or for field repair or...

Page 8: ...ons cover the general appearance of the units at the time of publication and the manufacturer reserves the right to make changes in design and construction at any time without notice For replacement p...