Feasycom FSC-SYR16-7DB Instruction Manual Download Page 3

Shenzhen Feasycom Co.,Ltd

Page

3

/

11

www.feasycom.com

I

Introduction

1. The product has multi-protocol compatibility, fast reading rate, waterproof appearance design, to
meet the requirements of harsh working environment.

2. Fully support ISO-18000-6C (EPC G2) electronic tags;

3. Support USB, RS232 and Wiegand26/34 and other communication methods;

4. Output power up to 30dbm adjustable, support timing mode, master-slave mode, trigger mode and
other modes of operation;

5. Application suitable for: vehicle access control, non-stop automatic toll collection, personnel
access control management, logistics monitoring, production automation management and other
fields.

1

Technical Parameters

Operating
frequency

Standard configuration ISM 902

928MHz or ISM 865

868MHz optional, other bands

can be customized.

Antenna Gain

Built-in circularly polarized antenna with 7dBi gain

Pact

ISO18000-6C

EPC G2

Development kit

Provide SDK development kit, and provide C#, VC, VB, Java, Delphi development
routines

Hardware

Provide test DEMO and automatic card writing, card reading DEMO, convenient for
customers to issue and write cards

Output power

0~30dBm

Software adjustable

Communications
interface

N-shape

Wiegand26/34, RS232/RS485, USB

E-shape

Wiegand26/34, RS232/RS485, TCP, USB

Input interface

1 Trigger Input

Reading method

Timed automatic card reading and externally triggered controlled card reading, set by
software

Reading speed

Less than 6ms per 64bits average read time for a single card, set by software

Reading distance

0-5 m (0~8 m for high power)

(The reading distance is related to the tag and the field

environment)

Operating
temperature

-40℃~+65℃

Storage
temperature

-45℃~+95℃

Shenzhen 

Feasycom Co., 

LTD

Summary of Contents for FSC-SYR16-7DB

Page 1: ...Shenzhen Feasycom Co Ltd Page 1 11 www feasycom com FSC SYR16 7DB Long distance range ultra high frequency electronic label reader Instruction manual S h e n z h e n F e a s y c o m C o L T D...

Page 2: ...of operation and wiring instructions 6 1 Read write wiring instructions 6 2 Label operation 6 3 The way of work 7 4 ID neighbor discrimination 7 Read write configuration 7 Read write installation 8 1...

Page 3: ...68MHz optional other bands can be customized Antenna Gain Built in circularly polarized antenna with 7dBi gain Pact ISO18000 6C EPC G2 Development kit Provide SDK development kit and provide C VC VB J...

Page 4: ...can be widely used in the following fields in particular taking advantage of the good characteristics it possesses 1 Transport management road and railway transport management and container transport...

Page 5: ...a wave range at the same time 3 Write tag data can write data to the specified tag storage area 4 It can be directly connected to control devices with standard Wiegand26 34 interface without developme...

Page 6: ...the reader during the test to ensure the card reading effect d Wigan communication interface must be connected to GND ground e The installation height is above 1 8M and the diameter of the vertical po...

Page 7: ...the data through the specified communication port output The operation of the label is read only 3 TRIGGER READ When a low level is input to the trigger input port the reader starts to read the card...

Page 8: ...www feasycom com For DEMO software use please refer to the UHF Setup Software Manual IV Installation of the reader 1 Installation of the reader Mounting Clip Codes brackets Back of the reader S h e n...

Page 9: ...2 2m and it is preferable to use stainless steel with a wall thickness of more than 1 2mm Use the fasteners provided in the FSC SYR16 7DB reader box to fix the reader to the top of the pole Adjust th...

Page 10: ...ite installation and implementation is generally based on site conditions to determine Explained below a Field installation mode 1 road without intermediate isolation of the security island road contr...

Page 11: ...e close to the road gate equipment at the same time so that the effective range of its read tag the farthest straight line away from 0 5 m to 8 m can cover the entrance and exit of the inlet and outle...

Reviews: