background image

FSC-BP301W Datasheet

To set up FSC-BP301W through AT commands, it usually needs to be operated on a computer. So
first, you need to establish a serial port debugging environment on your computer. Serial
debugging requires the computer to have a free serial port, and it also needs to run the serial
debugging software on the computer.

5.1.1 Serial debugging hardware preparation

Connect FSC-BP301W to the DB9 male socket of the computer. If there is no RS232 interface on
the computer, you need to purchase a USB-to-serial adapter or a USB-to-serial cable to add a
serial port for the computer.

5.1.2 Preparation of serial port debugging software

A variety of serial port debugging software can be downloaded online, users can choose
according to their own preferences. It is recommended to use Feasycom serial port assistant V1.2
debugging tool, users can contact Feasycom technical support. Carriage return line feed
characters must be added to the end of FSC-BP301W AT commands, by checking the option of
"Send New Line" if use Feasycom serial port tool. The operation is as follows

5.1.3 Send AT command

Start the serial port tools, select the physical serial port number of FSC-BP301W connect with the
computer, set the baud rate and other parameters of the serial port to keep it consistent with the
WIFI serial port parameters of the FSC-BP301W (default 115200, N, 8, 1), and then "open serial
port". Send test command AT, if it returns OK, it means that the AT command debugging
environment is established, and you can send other AT commands to set FSC-BP301W.
For detailed instructions.Please refer to the <FSC-BW236 Programming User Guide V3.1
(Universal).pdf> document.

6.Product packing list

One FSC-BP301W serial WIFI adapter

One SMA antenna

An instruction manual