13
Response
: +SSP=Param
2.1.10.
Accept/Reject Remote Pairing Request
Format
: AT+CFM=Param1, Param2
Param1: 12 Bytes MAC address of remote device
Param2: 0/1
(0) Reject remote pairing request
(1) Accept remote pairing request
Description
: Only used for pairing request in pairing mode 3, see AT+SSP
2.1.11.
Read/Write Class of Device
Format
: AT+COD{=Param}
Param: Class of device (6 bytes ASCII, default:240404 Handsfree device)
Response
: +COD=Param
2.1.12.
Read/Clear Paired Record
Format
: AT+PLIST{=Param}
Param:(0/1~8/12 Bytes MAC address)
(0) Clear all paired record
(1~8) Clear specific paired record with index
(MAC) Clear specific paired record with MAC address
Response1
: +PLIST=Param1, Param2, Param3{, Param4}
Param1: (1~8)
Paired device’s index
Param2: (MAC)
Paired device’s MAC address
Param3: A base-10 representation of a bit field, support profiles of device, see AT+PROFILE
Param4: (UTF8)
Paired device’s name
Response2
: +PLIST=E: End of the paired record
Example
: R
ead module’s paired record
<<
AT+PLIST