background image

3

 

 

 

2. 

Installation P

rocedure

 

 

1. 

Please refer to the 

drawing included in the 

Annex

 

of this manual that describe

s

 

the installation holes of 

the 

keypad

 

and the optional cover CTP

-

A1.

 

2. 

Mark the holes on the surface 

where the

 

keypad

 

and cover will be installed, according to the drawing o

Annex I. 

One possible method is to attach this drawing to the surface of the panel. 

Please refer to figure 

2

a

 

below.

 

 

 

2a. Installation holes marked

 

 

2b. Installation holes drilled

 

Figure 2. Making the installation holes.

 

 

3. 

D

rill the holes 

according to the diameter

s and tolerances 

desc

ribed in the drawing of 

Annex

Refer to 

figure 2b. 

After drilling, e

nsure

 

that 

the surface 

is clean 

from shavings and

 

remove the protection tape

 

 

(if any)

.

 

 

4. 

Ensure  that  the  upper  (small)  metal  positioner  is  loose  by  unfastening  slightly  the  2  fixing  screws

,

 

as 

shown in figure 

3

 

below.

 

 

Figure 

3

. Slightly unfastening the 2 screws of the upper metal positioner 

 

Summary of Contents for TP-A1

Page 1: ...nction with the instruction manual of FRENIC HVAC FRENIC AQUA FRENIC Lift FRENIC Ace inverters and TP A XXX keypad to become familiar with proper handling and correct use Improper installation may res...

Page 2: ...e cover as shown in figure 1 Figure 1 CTP A1 cover appearance The cover has no apparent cracks or any deformation 4 fixing screws are already placed in the 4 fixing holes of the cover as shown in figu...

Page 3: ...the panel Please refer to figure 2a below 2a Installation holes marked 2b Installation holes drilled Figure 2 Making the installation holes 3 Drill the holes according to the diameters and tolerances...

Page 4: ...t interferes with the upper side of the keypad Then fasten completely the 2 fixing screws as shown in figure 4 below Check that the keypad does not fall apart Figure 4 Fastening the 2 screws of the up...

Page 5: ...be hardly seen as shown in figure 6b below The screws provided are suitable for a panel door thickness up to 2 mm For panels thicker than 2 mm please consult with Fuji Electric representative 6a Fixin...

Page 6: ...6 Annex Installation holes drawing...

Page 7: ...e found or any suggestions you may have for generally improving the manual In no event will Fuji Electric Europe GmbH be liable for any direct or indirect damages resulting from the application of the...

Page 8: ...8 Fuji Electric Europe GmbH Goethering 58 63067 Offenbach am Main Germany www fujielectric europe com info inverter fujielectric europe com...

Reviews: