FE FRENIC-Ace Instruction Manual Download Page 7

Table 11-2 Detailed Function Description (Output) 

Function 
code

 

Data 

Output signal name 

Terminal function and setting content description 

 

o21 

 

 

Output frequency 

(before slide 

compensation) 

LSB

MSB

O1

O2

O3

O4

O5

O6

O7

O8

 

100% of max. output frequency / 8-bit 

 

 

 

Output frequency 

(after slide compensation)

LSB

MSB

O1

O2

O3

O4

O5

O6

O7

O8

 

100% of max. output frequency / 8-bit 

 

 

 

Output current 

LSB

MSB

O1

O2

O3

O4

O5

O6

O7

O8

 

200% of inverter rated output current / 8-bit 

 

 

 

Output voltage 

LSB

MSB

O1

O2

O3

O4

O5

O6

O7

O8

 

100% of 250 V / 8-bit: 200 V series 
100% of 500 V / 8-bit: 400 V series 

 

 

 

Output torque 

LSB

MSB

O1

O2

O3

O4

O5

O6

O7

O8

 

200% of motor rated torque / 8-bit 

 

 

 

Load factor 

LSB

MSB

O1

O2

O3

O4

O5

O6

O7

O8

 

200% of motor rated load / 8-bit 

 

 

 

Power consumption 

LSB

MSB

O1

O2

O3

O4

O5

O6

O7

O8

 

200% of inverter rated output / 8-bit 

 

 

 

PID feedback value (PV) 

LSB

MSB

O1

O2

O3

O4

O5

O6

O7

O8

 

100% of feedback value / 8-bit 

 8 

Detected 

speed/estimated 

speed 

LSB

MSB

O1

O2

O3

O4

O5

O6

O7

O8

 

100% of max. output frequency / 8-bit 

 

- 7 - 

Summary of Contents for FRENIC-Ace

Page 1: ...our product contact the shop where you bought the product or your local Fuji branch office Fig 2 1 Front of Card Fig 2 2 Back of Card Screw attachment hole Removal knob SW11 Model CN1 Screw attachment...

Page 2: ...ransistor output 1 to 8 1 All types of monitor data output frequency output current etc set with function code o21 can be output as 8 bit binary output signals 2 When function code o21 is set to 99 al...

Page 3: ...It is also possible to switch between the SINK and SOURCE methods for inverter unit digital input terminals Set the SINK SOURCE method setting the same as that for the inverter unit 8 1 2 Connecting...

Page 4: ...atus can be displayed with an LED segment ON OFF indication and hexadecimal indication Assignment of each signal is as follows Refer to the inverter unit instruction manual for details on menu No 4 I...

Page 5: ...before slide compensation 100 8 bit Output frequency max output frequency x 255 1 Output frequency after slide compensation 100 8 bit Output frequency max output frequency x 255 2 Output current 200 8...

Page 6: ...t resolution 1Hz range 2 Upper lower limiters are given priority 3 When values greater to or equal than the maximum output frequency are input the maximum output frequency is output 99 General purpose...

Page 7: ...O5 O6 O7 O8 200 of inverter rated output current 8 bit 3 Output voltage LSB MSB O1 O2 O3 O4 O5 O6 O7 O8 100 of 250 V 8 bit 200 V series 100 of 500 V 8 bit 400 V series 4 Output torque LSB MSB O1 O2 O...

Page 8: ...100 of max output frequency 8 bit 17 Synchronous angle deviation LSB MSB O1 O2 O3 O4 O5 O6 O7 O8 100 of deviation 180 deg to 180 deg 8 bit 18 Inverter cooling fin temperature LSB MSB O1 O2 O3 O4 O5 O6...

Reviews: