background image

9

Approximate STP / IST Specifications

Operating

Pressure (PSI)

PMA

Length (in)

S.F. 

Amps

Locked

Rotor Amps

Winding Resistance

Model

Description

R-B

R-O

B-O

STP33

*

208 / 230 V, 60 Hz, 1 ph

27

16

3.1

11

27

19

8

STP75

*

208 / 230 V, 60 Hz, 1 ph

30

18.25

6.1

27

20

17

3

STP150

*

208 / 230 V, 60 Hz, 1 ph

32

21

10.5

39

15

13

2

STPH150

*

208 / 230 V, 60 Hz, 1 ph

45

21.75

10.5

39

15

13

2

STP200

+

208 / 230 V, 60 Hz, 1 ph

36

23.75

11.4

41

4.6

3

1.8

STPH200

+

208 / 230 V, 60 Hz, 1 ph

46

24.5

11.4

41

4.6

3

1.8

STP75B

++

200 / 250 V, 50 Hz, 1 ph

37

20.5

5.6

23

27

23

4

STP150B

++

200 / 250 V, 50 Hz, 1 ph

38

22.75

10.2

28

16

13

3

STPH150B

++

200 / 250 V, 50 Hz, 1 ph

48

23.25

10.2

28

16

13

3

STP200B

200 / 250 V, 50 Hz, 1 ph

37

25.75

10.9

36.5

5.5

3.5

2

STPH200B

200 / 250 V, 50 Hz, 1 ph

44

26.25

10.9

36.5

5.5

3.5

2

STP75C

380-415 V, 50 Hz, 3 ph

**

37

19.75

2.1

10

29

29

29

STP150C

380-415 V, 50 Hz, 3 ph

**

38

21.75

3.4

14

14

14

14

STPH150C

380-415 V, 50 Hz, 3 ph

**

48

22

3.4

14

14

14

14

STP200C

380-415 V, 50 Hz, 3 ph

**

37

23.5

4.1

22.5

11.6

11.6

11.6

STPH200C

380-415 V, 50 Hz, 3 ph

**

44

24

4.1

22.5

11.6

11.6

11.6

IST / STPVS2

^

190 V, 70 Hz, 3 ph

24-42

20

6.7

N / A

2.5

2.5

2.5

ISTVS4 / STPVS4^^ 190 V, 70 Hz, 3 ph

24-42

25

14.4

N / A

1.2

1.2

1.2

 

Symbol Key

 

*

  Use a 15 µF, 370 V, single phase, 60 Hz capacitor

 

+

  Use a 40 µF, 370 V, single phase, 60 Hz capacitor

 

++

 Use a 15 µF, 440 V, single phase, 50 Hz capacitor

 

‡ 

Use a 40 µF, 440 V, single phase, 50 Hz capacitor

 

  190 V, 70 Hz, 3 ph power to variable speed units is output from IST-VFC or 

Mag

VFC only (VFC’s are powered 

by 200-250 V, 50 or 60 Hz, single or 3 phase input)

 

 

^

  Use with IST-VFC or 

Mag

VFC controller only, No Capacitor

 

^^

 Use with 

Mag

VFC controller only, No Capacitor (3 phase input is required for full VS4 output))

 

**

  No capacitor is used with 3 phase pump motor assemblies

Note:

  The models listed in the table above may contain (ANZ) for ANZEX certified pumps, or (ATX) for ATEX certified 

pumps.

Warning

FE Petro’s STPs are designed for use with motor fuels, and they are UL listed for blend 

concentrations of:

Standard Models

AG (Alcohol / Gasoline) Models

0% - 15% ethanol or methanol and gasoline

0% - 85% ethanol or methanol and gasoline

20% MTBE with 80% gasoline

20% MTBE with 80% gasoline

20% ETBE with 80% gasoline

20% ETBE with 80% gasoline

17% TAME with 83% gasoline

17% TAME with 83% gasoline

Diesel, fuel oil, avgas, jet fuel, or kerosene may also be used with our PMAs. The maximum liquid 

viscosity for a product is 70 S.S.U. at 60° F.
Using our PMA in liquids other than those mentioned above has not been tested. The reaction of 

other liquids with seals and wetted surfaces of the pump is unknown. A hazardous situation may 

result from using other liquids with our pump.

Summary of Contents for STP

Page 1: ...ixed Variable Length Installation and Owner s Manual 2009 400604005 Rev 15 Franklin Fueling Systems 3760 Marsh Rd Madison WI 53718 USA Tel 1 608 838 8786 800 225 9787 Fax 1 608 838 6433 www franklinfu...

Page 2: ...toring equipment is often housed in containment sumps designed to trap hazardous liquid spills and prevent contamination of the environment and as a consequence containment sumps can trap dangerous am...

Page 3: ...e PEI RP100 Latest Edition Recommended Practices for Installation of Aboveground Storage Systems for Motor Vehicle Fueling The Petroleum Equipment Institute PEI RP200 Latest Edition Installation of Un...

Page 4: ...the discharge casting Improper alignment could damage the wire lead or motor pins Failure to push PMA up snug against the discharge casting before tightening cap screws or failure to use a cross patte...

Page 5: ...ser thread engagement 1 6 Length bottom of riser to end bell 90 Figure 5 Measure Tank 16 Hold the manifold securely to the surface to prevent damage while setting length To allow movement of the teles...

Page 6: ...rdware pack p n 400301903 as shown in figure 10 Figure 10 Wire Through Contractor s Plug 22 Using the screwdriver slide the contractors plug into its seat in the discharge manifold Tighten the two scr...

Page 7: ...the loosening direction during the tightening process may scrape away the thread sealing compound making it impossible to perform a tank tightness test This may also create a potential site for fuel...

Page 8: ...t be filled with wires or a celcon rod to enable it to seal 36 Replace the junction box cover and tighten securely The pump discharge manifold has two labeled ports one for the syphon system and one f...

Page 9: ...60 Hz capacitor Use a 40 F 370 V single phase 60 Hz capacitor Use a 15 F 440 V single phase 50 Hz capacitor Use a 40 F 440 V single phase 50 Hz capacitor 190 V 70 Hz 3 ph power to variable speed unit...

Page 10: ...ssure relief valve in the check valve so it does not relieve line pressure back to the tank Syphon Systems Optional Syphoned tanks should be of the same diameter with tank bottoms located on the same...

Page 11: ...11 Wiring Diagram 1...

Page 12: ...e For further wiring diagrams see installation and owners manuals that came with pump controller Wiring must conform to all federal state and local electrical codes Contact FE Petro Technical Support...

Page 13: ...g 17 400600002 5 16 24 x 7 16 Set Screw for VL units only 3 18 400333015 O Ring Motor Discharge 1 19 400264009 5 16 18 x 1 1 8 Socket Head Cap Screw 4 20 400263004 5 16 High collar Lock Washer may pur...

Page 14: ...0280001 3 8 Standard Flat washer may purchase locally 2 10 400651930 Junction Box Assembly includes two of each Item 7 8 9 1 11 400210212 O Ring 2 Item Part Description Qty 13 400200930 Wire Connector...

Page 15: ...1 Bracket Power Switch 1 3 400158901 Light Assembly 120V CBS 1 400158902 Light Assembly 240V CBBS 1 4 400215931 Relay 30A 120V 1 400215933 Relay 30A 240V 1 5 400278005 Terminal Strip 1 6 402410001 Lab...

Page 16: ...est port NPT Vapor Recovery Discharge Port 1 NPT Riser Column Pipe Centerline Riser Column Pipe Centerline 11 70 7 55 R 10 45 8 12 R 3 00 5 80 3 63 Leak Detector Port 2 NPT Discharge Outlet 2 NPT 12 5...