3.
Timing Inputs
The TBox models 1x and 2x offers 4 inputs.
Manual Push Buttons (inputs 1 to 4)
Jack-Mono inputs (inputs 1 to 4)
Working contact without potential (short-circuit)
Each press of the button or short-circuits on the Inputs are stored in the TBox memory, with
associated date and time of impulse as CSV files.
The user has the ability to configure a locking time using the “TBox-Setup” App. This facility
allows the blocking of undesired impulses corresponding to the channel configured.
E.g. – to ignore multiple inputs from dirt or snow dust
4.
Mini-USB
The Mini-USB connector has various functions including:
External power supply and battery charging
COM port emulation for RS232 communication and data transfer
- Real time of day in many formats (FDS, TAG Heuer, Alge, Seiko)
- Configure the TBox-Radio options and parameters (with the app “TBox-Setup”)
2GB USB Flash Drive
- All impulse data are stored in a .csv file on the drive
A new file is created every time the TBox-Radio is swiched ON
- User needs to maintain sufficient memory availability to ensure storage of data
- The space required for a competition of 1000 times is approximately 40 Kbytes
- Flash Drive access is only possible when the TBox-Radio is turned OFF