In cases where the barrel connector is not desired, you can use the alternate power input connector
(J8) with supports directly plugging in 20-26 AWG wire with maximum 5A current per contact. The
datasheet for this J8 connector (PCB terminal block - PTSM 0,5/ 2-2,5-H SMD WH R24 – 1814634)
can be found at
To verify that the ELI101-CPW unit is correctly powered you may check the 12VDC input with a
Fluke meter or scope by probing the +12V and GND contacts shown below. Please verify that the
12VDC is present, is within the +/- 5% tolerance and is free from excessive noise or AC ripple.
Figure 4. ELI101-CPW Power Test Points
Extended Display Information Data (EDID)
ELI uses Extended Display Identification Data (EDID) for automatic configuration with many
operating systems. You can find out more on our website at