0
BMIC Operators Guide
Version 1
Warning:
This manual contains important safety and operating information.
Please read, understand and follow the instructions in the manual.
Page 1: ...0 BMIC Operators Guide Version 1 Warning This manual contains important safety and operating information Please read understand and follow the instructions in the manual...
Page 2: ...s Introduction Equipment List Page 3 Bmic Controls Using the Bmic 4 LED indication 4 Care of the Bmic 4 Battery warning 5 Battery replacement 5 Charging the Bmic batteries 5 Operator Guidance 7 Techni...
Page 3: ...tion and a volume sensitivity rotary control An LED indicates operation and battery status It can be used to confirm the position of underground leaks audibly from ground level sound pipe fittings pen...
Page 4: ...ipod foot on hard ground and use the probe rods on soft ground or when accessing water pipe fittings Connect the headphones to the connector and connect the microphone cable to the forward connector P...
Page 5: ...ntually need to be replaced To do this undo the four screws underneath the hand held unit and separate the two halves of the Bmic unit Gently pull out the battery holder and replace the battery When r...
Page 6: ...the water and the pipe wall as well as into the ground around the pipe The noise travels much better through hard materials so that the noise travels much further along metallic pipes than asbestos ce...
Page 7: ...When you are listening on pipe fittings the location of the point of maximum noise will probably not indicate the leak position only the fitting closest to the leak The noise level will also appear s...
Page 8: ...Ohms 4 pin Amphenol connector to control unit LED Green normal operation Red low battery power Optional accessories High specification aviation quality headphones Car cigarette lighter adapter with 12...
Page 9: ...8 Fluid Conservation Systems 1960 Old Gatesburg Road STE 150 State College PA 16803 800 531 5465 fluidconservation com MAN 080 0002 A BMIC Operators Guide Version 1...