FC Unwired GCPG900 User Manual Download Page 1

 

 

 

1/14 

Ver 0.1 

 

GCST900 / GCPG900              

User Guide  

 

 

FC Unwired Hardware 

 
 
 
 

 

 
 
 

 

 

 

FC Unwired

 

Inc. 

Version 0.1 

 

 

 

Summary of Contents for GCPG900

Page 1: ...1 14 Ver 0 1 GCST900 GCPG900 User Guide FC Unwired Hardware FC Unwired Inc Version 0 1 ...

Page 2: ... only and does not constitute any commitment or obligation on the part of Nakra Labs with respect to any future products services or undertakings No rights or licenses to any concepts or ideas contained in such information are granted to the recipient of this document Nakra Labs may at its sole discretion pursue not pursue or modify any of its intentions or activities described in this document Th...

Page 3: ...5 2 2 Sensor Transmitter GCST900 6 2 3 Bed Sensor Pad GCPAD4080 7 3 Getting started 7 3 1 Menu tree of Wearable Pager 8 3 1 1 Menu 8 3 1 2 Notification Icons 9 3 2 Before Starting 9 3 2 1 Charging Wearable Pager 9 3 2 2 Setting up the Group for Wearable Pager 9 3 3 Personal Care 10 3 3 1 Fall Prevention Wearable Pager Bed Sensor Pad 10 4 Disclaimers and Warning 12 ...

Page 4: ...4 14 Ver 0 1 Change History Version Date Owner What was modified or added 0 1 02 Jul 2021 GY Yang Initial pass ...

Page 5: ...r GCPG900 A Wearable pager notifies Sensor Transmitter s alert information to caregivers who are wearing the pagers The LED display on the pager shows a 4 digit numbers that indicates the location of the alert The number displayed can be set by the user to identify the room and bed setting off the alert The simple setup network is established see section 3 3 for instructions on setting up the netw...

Page 6: ...ST900 The Sensor Transmitter is connected to the Bed Sensor Pad and broadcasts sensor information to Wearable Pagers The Sensor Transmitter should be registered with the Wearable Pagers before it is transmitted sensor data will be received ...

Page 7: ...e connection for proper operation Installing Sensor pad and Sensor Transmitter to bed Place Bed Sensor Pad on the bed and cover it with bed sheets To detect when the patient is awake and sitting up in bed place the Bed Sensor Pad below the upper back of patient To detect when the patient gets out of bed place Bed Sensor Pad in the middle of the bed just below the patient s buttocks If possible pla...

Page 8: ...mode to bell and vibration Group 00 49 Set the group number of Wearable Pager Registration Pad Register Sensor Pad Mat Register Floor Mat Transfer Transfer Network Setting to Wearable Pager or Central Monitor Receive Receive Network Setting from Wearable Pager or Central Monitor Initialize Erase all network Setting reset Channel 01 03 Set Radio Channel Language 한국어 Korean English English ...

Page 9: ...rging 3 2 2 Setting up the Group for Wearable Pager Within a network specific sensors can be grouped together for region or functionality eg all sensors in the intensive care unit or all sensors in a general ward to one or more Wearable Pagers Set the group ID to non zero value 01 49 Sensor location information will only be transmitted on the Wearable Pager with same group ID To receive sensor inf...

Page 10: ...nsor Pad s Location Identifier Information User can enter 4 digit number to identify Bed Sensor Pad location For example upper 2 digit and lower 2 digit can be used to identify room number and bed number respectively This can be done while registering the Sensor Transmitter as detailed below 1 From IDLE Mode of the Wearable Pager Press OK OK UP UP OK OK buttons to enter Sensor Information setting ...

Page 11: ...d waits for the registration request from Sensor Transmitter 2 Press UP and DOWN buttons on the Sensor Transmitter simultaneously for more than 3 seconds The LED on the Sensor Transmitter will blink and it will send a request for registration to the Wearable Pager 3 After the registration is completed the Wearable Pager will display OK for 2 seconds and return to the Registration Menu ...

Page 12: ...r Pads by repeating the procedure outlined in Section 3 3 1 1 to Section 3 3 1 3 with additional Bed Sensor Pads and Sensor Transmitters 4 Disclaimers and Warning Disclaimer The manufacturer shall not be held liable for any claims or damages from the patient falling or wandering This device is designed as a secondary support mechanism the patient s primary motion detection management program Warni...

Page 13: ...nsitive to environmental conditions and should be used only as a secondary device to the patient s movement detection management program Battery charge must be checked regularly for charge and operation The Pager when used must be fully recharged ...

Page 14: ...evention Transmitter Rated Supply Voltage DC 3 0 V OPERATING FREQUENCY 920 5 MHz 923 5 MHz MODULATION TYPE CSS RF OUTPUT POWER 17 16 dBm NUMBER OF CHANNEL 3 Channel ANTENNA TYPE PCB Antenna ANTENNA GAIN 3 61 dBi List of each Osc or crystal Freq Freq 1 MHz 32 MHz ...