Tighten

Screw

Adapter holds

Fixture in place.

Drywall Adapter

Adapter Screw

THIS DOCUMENT PROPRIETARY TO FC LIGHTING, INC. ANY UNAUTHORIZED TRANSFER, USE OR REPRODUCTION IS STRICTLY PROHIBITED.

©2016 FC LIGHTING, INC.

 

FCSL100 SERIES 

 -  

INSTALLATION INSTRUCTIONS - 

page 2 of 2

CAUTION:  BEFORE CONNECTING THE FIXTURE TO A POWER SUPPLY, MAKE SURE THE POWER IS SWITCHED OFF.

NOTE

:  

Faceplates

 - The Faceplate type used determines fixture installation.     

FCSL101-FCSL106 mounts flush to front of Fixture Lip. (Fig. 1) and 

B

 

(HB)

 

FCSL108-FCSL110 fits over (wraps around) Fixture Lip. (Fig. 2) and 

C

 

(DRW)

GENERAL

:

1.  Before starting the installation, make sure all electricity has been turned off and electrical 

breaker has been locked out and tagged out.

2.  To ensure the success of the installation, be sure to read these instructions and review the 

diagrams thoroughly before beginning.

3.   All electrical connections must be in accordance with local codes, ordinances, or the 

National Electrical Code.

NOTE

: The important safeguards and instructions appearing in this manual are not meant to 

cover all possible conditions and situations that may occur. 

DETAILED INSTRUCTIONS FOR FOR DRYWALL MOUNT USING

 

HANGER BRACKET OR 

DRYWALL ADAPTER (READ PAGE 1 OF INSTALLATION INSTRUCTIONS FIRST):

Flush mount 

B

 using Hanger Bracket, New Construction, dry or damp locations only.

NOTE

: PL version is not for through wiring. All connections must be water tight.

1)   Locate fixture between studs: 14.25” min to 22” max spacing between studs.
2)  Mark height location of bottom edge of step light on vertical studs. Place second mark

at 1/4” below this mark.

3)  With the housing on top of bars, locate top edge of hanger bars with lowest mark on

  studs. Use rounded tab to align bracket to front edge of stud. Fig. 3

4)  Use screws or nails to attach hanger bar to stud. Expand bar to meet second stud and

 attach at proper height.

5)  Run conduit, Romex, or AFC to housing and make connections. Pull wires to housing.
6)  Position housing left-to-right and twist c-bracket with pliers to hold in position as needed.
7)  Install dry wall and route for size of front flange of housing: 9-5/16” x 2-5/16” max

opening. 

Front edge of housing should be slightly recessed from face of drywall.

8) Return to remaining instructions on page one to complete installation steps.

Front mount 

C

 using Drywall Adapter, New Construction, dry or damp locations only.

NOTE

: PL version is not for through wiring. All connections must be water tight.

1)  Install dry wall and route for size, 8-5/16” x 2-5/16” for front mount.
2)  Secure fixture housing to forms outside of gasket area.
3)  With fixture lip in position, tighten Drywall Adapter Screw to hold fixure in place. Fig. 4 

4) Return to remaining instructions on page one to complete installation steps.

DETAILED ILLUSTRATION

JO Rev. 

0117

Fig. 4

Drywall Adapter 

(DRW)

Front of Fixture Lip 
Mounted Flush with 
wall using Hanger 
Bracket (

HB

) Fig. 3

Fixture 

Lip in 

Wall

B

Mounting for

 Fig.
 1

 F

acepla

te type.

BOSS REQUIRED FOR GROUND SCREW.   
8MM OD X 8MM TALL BLIND TAP 6-32, 8MM DEEP

 2.64 in 

INSERT TYP2

8-32 THREADED 

 2.8 in 

BLIND HOLE  TYP 4

3 X 6MM DEEP

22.23 TYP 2 

2 x 1MM DEEP

TYP 2

 .125 in 

 9.375 in 

 3 in. 

Pg. 1, Fig. 1

  

Faceplate mounts to 

Front of Fixture Lip. 

Use mounting 

B

Pg 1. Fig. 2

 

 Faceplate  fits 

over Fixture Lip. 

Use mounting 

C

BOSS REQUIRED FOR GROUND SCREW.   
8MM OD X 8MM TALL BLIND TAP 6-32, 8MM DEEP

 2.64 in 

INSERT TYP2

8-32 THREADED 

 2.8 in 

BLIND HOLE  TYP 4

3 X 6MM DEEP

22.23 TYP 2 

2 x 1MM DEEP

TYP 2

 .125 in 

 9.375 in 

 3 in. 

Fixture Lip

Fixture Lip against Wall

C

Mounting for

 Fig.
 2

 F

acepla

te type.

Fixture Lip

Fixture Lip 

Mounted in 

Front of Wall

Front of Fixture Lip 
Mounted in Front of 
wall using Drywall 
Adapter (

HB

) Fig. 4

Fixture Housing on Top of Bars

Stud

 2.64 in 

 9.375 in 

 14.25 in 

Stud

Fig. 3 

Hanger Bracket - 

(HB)