FCSL100 SERIES
-
INSTALLATION INSTRUCTIONS -
page 2 of 2
CAUTION: BEFORE CONNECTING THE FIXTURE TO A POWER SUPPLY, MAKE SURE THE POWER IS SWITCHED OFF.
NOTE
:
Faceplates
- The Faceplate type used determines fixture installation.
FCSL101-FCSL106 mounts flush to front of Fixture Lip. (Fig. 1) and
B
(HB)
FCSL108-FCSL110 fits over (wraps around) Fixture Lip. (Fig. 2) and
C
(DRW)
GENERAL
:
1. Before starting the installation, make sure all electricity has been turned off and electrical
breaker has been locked out and tagged out.
2. To ensure the success of the installation, be sure to read these instructions and review the
diagrams thoroughly before beginning.
3. All electrical connections must be in accordance with local codes, ordinances, or the
National Electrical Code.
NOTE
: The important safeguards and instructions appearing in this manual are not meant to
cover all possible conditions and situations that may occur.
DETAILED INSTRUCTIONS FOR FOR DRYWALL MOUNT USING
HANGER BRACKET OR
DRYWALL ADAPTER (READ PAGE 1 OF INSTALLATION INSTRUCTIONS FIRST):
Flush mount
B
using Hanger Bracket, New Construction, dry or damp locations only.
NOTE
: PL version is not for through wiring. All connections must be water tight.
1) Locate fixture between studs: 14.25” min to 22” max spacing between studs.
2) Mark height location of bottom edge of step light on vertical studs. Place second mark
at 1/4” below this mark.
3) With the housing on top of bars, locate top edge of hanger bars with lowest mark on
studs. Use rounded tab to align bracket to front edge of stud. Fig. 3
4) Use screws or nails to attach hanger bar to stud. Expand bar to meet second stud and
attach at proper height.
5) Run conduit, Romex, or AFC to housing and make connections. Pull wires to housing.
6) Position housing left-to-right and twist c-bracket with pliers to hold in position as needed.
7) Install dry wall and route for size of front flange of housing: 9-5/16” x 2-5/16” max
opening.
Front edge of housing should be slightly recessed from face of drywall.
8) Return to remaining instructions on page one to complete installation steps.
Front mount
C
using Drywall Adapter, New Construction, dry or damp locations only.
NOTE
: PL version is not for through wiring. All connections must be water tight.
1) Install dry wall and route for size, 8-5/16” x 2-5/16” for front mount.
2) Secure fixture housing to forms outside of gasket area.
3) With fixture lip in position, tighten Drywall Adapter Screw to hold fixure in place. Fig. 4
4) Return to remaining instructions on page one to complete installation steps.
DETAILED ILLUSTRATION
JO Rev.
0117
Fig. 4
Drywall Adapter
(DRW)
Front of Fixture Lip
Mounted Flush with
wall using Hanger
Bracket (
HB
) Fig. 3
Fixture
Lip in
Wall
B
Mounting for
Fig.
1
F
acepla
te type.
BOSS REQUIRED FOR GROUND SCREW.
8MM OD X 8MM TALL BLIND TAP 6-32, 8MM DEEP
2.64 in
INSERT TYP2
8-32 THREADED
2.8 in
BLIND HOLE TYP 4
3 X 6MM DEEP
22.23 TYP 2
2 x 1MM DEEP
TYP 2
.125 in
9.375 in
3 in.
Pg. 1, Fig. 1
Faceplate mounts to
Front of Fixture Lip.
Use mounting
B
Pg 1. Fig. 2
Faceplate fits
over Fixture Lip.
Use mounting
C
BOSS REQUIRED FOR GROUND SCREW.
8MM OD X 8MM TALL BLIND TAP 6-32, 8MM DEEP
2.64 in
INSERT TYP2
8-32 THREADED
2.8 in
BLIND HOLE TYP 4
3 X 6MM DEEP
22.23 TYP 2
2 x 1MM DEEP
TYP 2
.125 in
9.375 in
3 in.
Fixture Lip
Fixture Lip against Wall
C
Mounting for
Fig.
2
F
acepla
te type.
Fixture Lip
Fixture Lip
Mounted in
Front of Wall
Front of Fixture Lip
Mounted in Front of
wall using Drywall
Adapter (
HB
) Fig. 4
Fixture Housing on Top of Bars
Stud
2.64 in
9.375 in
14.25 in
Stud
Fig. 3
Hanger Bracket -
(HB)