Apply Silicone Bead

THIS DOCUMENT IS PROPRIETARY TO FC LIGHTING, INC. ANY UNAUTHORIZED TRANSFER, USE OR REPRODUCTION IS STRICTLY PROHIBITED.

©2016 FC LIGHTING, INC.

 

FCSL100 SERIES 

 -  

INSTALLATION INSTRUCTIONS 

page 1 of 2

CAUTION:  BEFORE CONNECTING THE FIXTURE TO A POWER SUPPLY, MAKE SURE THE POWER IS SWITCHED OFF.

NOTE

:  

Faceplates

 - The Faceplate type used determines fixture installation.     

FCSL101-FCSL106 mounts flush to front of Fixture Lip. (Fig. 1) and 

B

 

(HB)

 

FCSL108-FCSL110 fits over (wraps around) Fixture Lip. (Fig. 2) and 

C

 

(DWR)

GENERAL

:

1.  Before starting the installation, make sure all electricity has been turned off and electrical 

breaker has been locked out and tagged out.

2.  To ensure the success of the installation, be sure to read these instructions and review the 

diagrams thoroughly before beginning.

3.   All electrical connections must be in accordance with local codes, ordinances, or the 

National Electrical Code.

NOTE

: The important safeguards and instructions appearing in this manual are not meant to 

cover all possible conditions and situations that may occur. 

INSTALLATION INSTRUCTIONS:

A)   Remove the two (2) socket head screws holding Lens and Faceplate to fixture. Then remove 

internal lamping components (guts) from fixture.

 

FOR CONCRETE POUR:

  Be sure to level and stabilize fixture.  Cover any holes and knockouts on 

fixture housing to prevent leakage. Seal the fixture to prevent water leakage during operation.

FOR DRYWALL MOUNT:

  Cut hole in drywall (2-5/8” x  9-3/8”) for flush mount 

B

 or 

(2-5/16” x 8-5/16”) for front mount 

C

. Refer to detailed instructions on page 2.

NOTE

: PL version is not for through wiring. All connections must be water tight.

1)   Connect conduit or code approved electrical fitting through one of the 7/8” diameter holes 

on the back or side of the fixture. Secure fixture housing to forms outside of gasket area. 

Refer to Fig. 3 on pg. 2 using Hanger Brackets and Drywall Adapters for Front Mounted 

drywall application.

2)  After fixture is mounted, connect your ground wire to green ground wire on fixture.
3)  Replace internal components with approved lamp.
4)  Attach lens and frame, replace two (2) socket screws tightening evenly.
5)   Restore power and test fixture.  If fixture does not turn on, disconnect power before 

checking for problems.

IMPORTANT:

 Fixtures are listed for installation with liquid tight or rigid wall conduit only.     

D

 Fixtures installed without a silicone bead will void the warranty.

DETAILED ILLUSTRATION

JO Rev. 

0218

Fig. 3

Drywall Adapter

(DWR)

Drywall Adapter

Tighten

Screw

Adapter holds

Fixture in place.

Adapter Screw

Back of Fixture

Front of Fixture Lip Mounted Flush with Wall. 

Use 

HB

 for proper installation.

Fixture Lip Mounted in Front of Wall. 

Use 

DWR

 for proper installation

Fixture Lip in Wall

Same for concrete or drywall application.

Same for concrete or drywall application.

Fixture Lip against Wall

Fixture Lip

Gasket Area

A

B

C

Mounting for

 Fig. 1

 Faceplate type.

Mounting for

 Fig. 2

 Faceplate type.

BOSS REQUIRED FOR GROUND SCREW.   
8MM OD X 8MM TALL BLIND TAP 6-32, 8MM DEEP

 2.64 in 

INSERT TYP2

8-32 THREADED 

 2.8 in 

BLIND HOLE  TYP 4

3 X 6MM DEEP

22.23 TYP 2 

2 x 1MM DEEP

TYP 2

 .125 in 

 9.375 in 

 3 in. 

BOSS REQUIRED FOR GROUND SCREW.   
8MM OD X 8MM TALL BLIND TAP 6-32, 8MM DEEP

 2.64 in 

INSERT TYP2

8-32 THREADED 

 2.8 in 

BLIND HOLE  TYP 4

3 X 6MM DEEP

22.23 TYP 2 

2 x 1MM DEEP

TYP 2

 .125 in 

 9.375 in 

 3 in. 

Fig. 1

   Faceplate mounts to 

Front of Fixture Lip. 

Use mounting

B

Fig. 2

 

 Faceplate  fits 

over Fixture Lip. 

Use mounting

C

Fixture Lip

BOSS

 REQUIRED

 FOR GROUND

 SCREW.

   

8MM

 OD

 X 8

MM

 TAL

L BLIN

D TAP

 6-32

, 8MM

 DEEP

 2.64 in 

INSER

T TYP2

8-32 

THRE

ADED 

 2.8 in 

BLIN

D HO

LE  

TYP

 4

3 X 

6MM

 DEE

P

22.23 TYP 2 

2 x 

1MM

 DEE

P

TYP 2

 .125 in 

 9.375 in 

 3 in. 

Back of Fixture

1/2” trade connector openings

Fixture Lip

Fixture Housing

BOSS REQUIRED FOR GROUND SCREW.   
8MM OD X 8MM TALL BLIND TAP 6-32, 8MM DEEP

 2.64 in 

INSERT TYP2

8-32 THREADED 

 2.8 in 

BLIND HOLE  TYP 4

3 X 6MM DEEP

22.23 TYP 2 

2 x 1MM DEEP

TYP 2

 .125 in 

 9.375 in 

 3 in. 

D

Apply Silicone Bead

D