background image

52

VHA 112SND

VHA 112SND

VHA 112SND

VHA 112SND

VHA 112SND

VHA 112SND

VHA 112SND

VHA 406ND

VHA 406ND

VHA 406ND

VHA 406ND

VHA 406ND

VHA 406ND

VHA 406ND

PRESET

Correct

 installation of VHA 112SND and VHA 406ND in the 3-way configuration

Incorrect installations in 3-way

configurations

Distance between 
acoustic centre

Fig. 1

The HORIZON system consists of three models:

• 

VHA 406ND:

 2-way bi-amplified speaker with 65Hz - 20kHz bandwidth (120Hz - 20kHz HP Filter ON)

• 

VHA 112SND

: 12” 1-way amplified subwoofer with 50Hz - 120Hz bandwidth (40Hz - 120Hz con “LF Extension” ON)

• 

VHA 118SND

: 18” 1-way amplified subwoofer with 30Hz - 100Hz bandwidth

The system is very versatile and is available in a variety of configurations to better adapt to the requirements of use; the pre-sets are designed to guaran

-

tee correct alignment of the system in amplitude and phase as the configuration used varies. 

It is very important to correctly configure all the controls 

in the speakers in order to avoid seriously compromising the final result

.

When the system includes 

VHA 406ND

 and 

VHA 112SND

, two modes of operation are possible:

• 

2 WAY + SUB SYSTEM

: “2 WAY” refers to the VHA 406ND model and “SUB” to the VHA 112SND model. In this mode the acoustic crossover is set to 

110Hz  and the system is assimilated to a “SAT+SUB”. The ratio between SUB and SAT can be chosen between 2:1 and 1:3 depending on how much 

energy is required below 110Hz and the physical distance between SUB and SAT can also vary accordingly depending on the number of SAT and 

SUB that make up the horizontal and vertical array. For example, an array can be configured with 2 x VHA 112SND and under 4 x VHA 406ND. This 
mode works correctly with any permissible configuration of the HORIZON system.

• 

3 WAY SYSTEM

: The combination of VHA 406ND and VHA 112SND is addressed to produce a 3-way speaker (LF+MF+HF) in which the VHA 

112SND speaker forms the first way (LF) and the VHA 406ND constitutes the two remaining ways (MF+HF). The acoustic crossover, in this case, 

is set to 230Hz and the system must respect precise rules in terms of the ratio of the two speakers (which must be strictly 1:1) and the distance of 

the acoustic centres ( which must be aligned vertically or horizontally and as close as possible). This configuration was conceived above all to have 
the maximum SPL and “headroom” in large configurations where the 12” woofer is used in all its potential to provide the system with the necessary 

energy supply on the LF range.

N.B. Both configurations can be accompanied by the VHA 118SND which is the “actual” subwoofer of the system and is required in the vast majority of 

“live” and “sound reinforcement” applications to provide the correct impact at low frequencies.
The possible combinations of speakers are:

• 

VHA 406ND

 in full-range (HP FILTER OFF): for voice or music with limited energy content at low frequencies.

• 

VHA 406ND (HP FILTER ON) + VHA 112SND

 in “2 WAY+SUB” or “3 WAY” configuration. The “LF EXTENSION” mode can be activated on VHA  

   112SND to obtain greater extension at low frequencies.

• 

VHA 406ND (HP FILTER ON) + VHA 112SND

 in “2 WAY+SUB” or “3 WAY” configuration (“LF EXTENSION OFF” mode) + VHA 118SND with a 

preset of your choice (mode VHA 112SND ON). In this configuration the preset “INFRA” offers the highest quality and timbre neutrality, while the 

“ORIGINAL” or “DEEP” pre-sets offers the maximum SPL ensuring the overlap between VHA 112SND and VHA 118SND. The “PUNCH” preset is 
not recommended.

• 

VHA 406ND (HP FILTER ON) + VHA 118SND

 (mode VHA 112SND OFF). In this configuration it is necessary to choose the  presets for VHA 406ND 

according to the number of speakers that compose the array, while is not allowed the use of presets in 3-way system configuration. For the VHA 

118SND in general the “INFRA” pre-set is not recommended while it is possible to choose from among the others available as required. The INFRA 
preset can only be used together with the “HP FILTER” OFF located in the VHA 406ND speaker which ensures a uniform response in the crossover 
area, even if energetically, at high volumes, the system may suffer a drop in performance in the 75Hz - 105Hz range, due to the limitation of the VHA 
406ND. The PUNCH pre-set offers a fast and high impact bass on 60 - 90Hz, particularly suitable in “live” mode.     

CONFIG PRST

SELECT

2 Way

CONFIG PRST

SELECT

3 Way

PRESET

SELECT

2 Way

PRESET

SELECT

3 Way

HPF

STATE

ON

SOUND PRST

SELECT

Low Extension

ON

CONFIG PRST

SELECT

VHA 112 Yes

CONFIG PRST

SELECT

VHA 112 No

1Sub

1 Top

1Sub

2 Top

1Sub

3 Top

2Sub

1 Top

(1 Box)

(2 Box)

(3-4 Box)

(5-6 Box)

1 Box

2 Box

3-4 Box

5-6 Box

1 Box

2 Box

3-4 Box

5-6 Box

CONFIG PRST

SELECT

2 Way

CONFIG PRST

SELECT

3 Way

PRESET

SELECT

2 Way

PRESET

SELECT

3 Way

HPF

STATE

ON

SOUND PRST

SELECT

Low Extension

ON

CONFIG PRST

SELECT

VHA 112 Yes

CONFIG PRST

SELECT

VHA 112 No

1Sub

1 Top

1Sub

2 Top

1Sub

3 Top

2Sub

1 Top

(1 Box)

(2 Box)

(3-4 Box)

(5-6 Box)

1 Box

2 Box

3-4 Box

5-6 Box

1 Box

2 Box

3-4 Box

5-6 Box

CONFIG PRST

SELECT

2 Way

CONFIG PRST

SELECT

3 Way

PRESET

SELECT

2 Way

PRESET

SELECT

3 Way

HPF

STATE

ON

SOUND PRST

SELECT

Low Extension

ON

CONFIG PRST

SELECT

VHA 112 Yes

CONFIG PRST

SELECT

VHA 112 No

1Sub

1 Top

1Sub

2 Top

1Sub

3 Top

2Sub

1 Top

(1 Box)

(2 Box)

(3-4 Box)

(5-6 Box)

1 Box

2 Box

3-4 Box

5-6 Box

1 Box

2 Box

3-4 Box

5-6 Box

CONFIG PRST

SELECT

2 Way

CONFIG PRST

SELECT

3 Way

PRESET

SELECT

2 Way

PRESET

SELECT

3 Way

HPF

STATE

ON

SOUND PRST

SELECT

Low Extension

ON

CONFIG PRST

SELECT

VHA 112 Yes

CONFIG PRST

SELECT

VHA 112 No

1Sub

1 Top

1Sub

2 Top

1Sub

3 Top

2Sub

1 Top

(1 Box)

(2 Box)

(3-4 Box)

(5-6 Box)

1 Box

2 Box

3-4 Box

5-6 Box

1 Box

2 Box

3-4 Box

5-6 Box

CONFIG PRST

SELECT

2 Way

CONFIG PRST

SELECT

3 Way

PRESET

SELECT

2 Way

PRESET

SELECT

3 Way

HPF

STATE

ON

SOUND PRST

SELECT

Low Extension

ON

CONFIG PRST

SELECT

VHA 112 Yes

CONFIG PRST

SELECT

VHA 112 No

1Sub

1 Top

1Sub

2 Top

1Sub

3 Top

2Sub

1 Top

(1 Box)

(2 Box)

(3-4 Box)

(5-6 Box)

1 Box

2 Box

3-4 Box

5-6 Box

1 Box

2 Box

3-4 Box

5-6 Box

CONFIG PRST

SELECT

2 Way

CONFIG PRST

SELECT

3 Way

PRESET

SELECT

2 Way

PRESET

SELECT

3 Way

HPF

STATE

ON

SOUND PRST

SELECT

Low Extension

ON

CONFIG PRST

SELECT

VHA 112 Yes

CONFIG PRST

SELECT

VHA 112 No

1Sub

1 Top

1Sub

2 Top

1Sub

3 Top

2Sub

1 Top

(1 Box)

(2 Box)

(3-4 Box)

(5-6 Box)

1 Box

2 Box

3-4 Box

5-6 Box

1 Box

2 Box

3-4 Box

5-6 Box

The ratio between the quantities of VHA 112SND and VHA 

406ND is fixed at 1:1. 
E.g. A configuration with 4 speakers must have no. 2 VHA 

112SND models and no. 2 VHA 406ND models. 
Furthermore, the two modules must respect a rule on their 

mutual positioning. (see fig.1)

VHA 112SND

 

PRESET

VHA 406ND

VHA 112SND

VHA 406ND

 

PRESET

Ratio between quantities 
of VHA 112SND and VHA 
406ND that compose the 

array in 2-WAY + SUB mode.

Number of VHA 406ND 
that compose the array in 

2-WAY+SUB 

or 

3-WAY 

modes.  The  3-WAY  mode  is 

not achievable if the VHA 
112SND model is not pre-

sent in the configuration.

Button for activating the low-

cut  filter  device  that  only  re

-

leases the highest frequencies 
of the “cut-off frequency”. N.B. 

the command, in a 3-way confi

-

guration, is “bypassed”. 

Activating this control ex-
tends the response to the low 
frequencies. TO BE USED 

EXCLUSIVELY  WHEN  THE 

VHA 112SA IS THE ONLY 

SUBWOOFER  OF  THE  SY

-

STEM.

2 WAY+SUB SYSTEM

VHA 406ND (HF+LF)

VHA 112SND (SUB)

SUB: SAT RATIO

2 WAY+SUB SYSTEM

VHA 406ND (HF+LF)

VHA 112SND (SUB)

3 WAY SYSTEM

VHA 406ND (HF+MF)

VHA 112SND (LF)

1:1 RATIO

3 WAY SYSTEM

VHA 406ND (HF+MF)

VHA 112SND (LF)

1:1 RATIO

CONFIG PRST

SELECT

2 Way

CONFIG PRST

SELECT

3 Way

PRESET

SELECT

2 Way

PRESET

SELECT

3 Way

HPF

STATE

ON

SOUND PRST

SELECT

Low Extension

ON

CONFIG PRST

SELECT

VHA 112 Yes

CONFIG PRST

SELECT

VHA 112 No

1Sub

1 Top

1Sub

2 Top

1Sub

3 Top

2Sub

1 Top

(1 Box)

(2 Box)

(3-4 Box)

(5-6 Box)

1 Box

2 Box

3-4 Box

5-6 Box

1 Box

2 Box

3-4 Box

5-6 Box

CONFIG PRST

SELECT

2 Way

CONFIG PRST

SELECT

3 Way

PRESET

SELECT

2 Way

PRESET

SELECT

3 Way

HPF

STATE

ON

SOUND PRST

SELECT

Low Extension

ON

CONFIG PRST

SELECT

VHA 112 Yes

CONFIG PRST

SELECT

VHA 112 No

1Sub

1 Top

1Sub

2 Top

1Sub

3 Top

2Sub

1 Top

(1 Box)

(2 Box)

(3-4 Box)

(5-6 Box)

1 Box

2 Box

3-4 Box

5-6 Box

1 Box

2 Box

3-4 Box

5-6 Box

VHA 118SND

Select “YES” mode only when the HORIZON system 
also includes the VHA 112SND model; in this way, 

through the “all pass” filters, perfect phase alignment 

between the two subwoofers is guaranteed.

VHA 112SND

VHA 112SND

VHA 112SND

VHA 112SND

VHA 112SND

VHA 112SND

VHA 112SND

VHA 406ND

VHA 406ND

VHA 406ND

Summary of Contents for HORIZON VHA406ND

Page 1: ...VHA 406ND 406N CODE 45494 IT MANUALE D USO EN OPERATING MANUAL Vertical Horizontal Active Line Array...

Page 2: ......

Page 3: ...w fbt it info fbt it INFORMAZIONI GENERALI 3 AVVERTENZE 4 CARATTERISTICHE GENERALI 5 Descrizione 5 Caratteristiche 5 DIMENSIONI 6 PANNELLO E INGRESSI 7 ALIMENTAZIONE 8 Alimentazione 220V 240V 8 Alimen...

Page 4: ...e alla pioggia o all umidit anomalie di funzionamento o cadute dell appa recchio ATTENZIONE RISCHIO DI SHOCK ELETTRICO NON APRIRE PER EVITARE IL RISCHIO DI SHOCK ELETTRICO NON APRIRE IL COPERCHIO NON...

Page 5: ...tazione universale 100 240Vac Il cabinet dotato di due ma niglie con inserti in gomma e meccaniche integrate per unire i diffusori ed angolarli tra loro da 5 a 20 a passo di 5 Particolare cura stata p...

Page 6: ...6 DIMENSIONI 612mm 24 09 397mm 15 62 360mm 14 17 20...

Page 7: ...ND VHA 406N 1 XLR input 2 Xlr link output 3 Porta compatibile con connettori etherCON RJ45 utilizzata per l in gresso di rete ethernet per controllo e monitoraggio remoto tramite INFINITO SOFTWARE MAN...

Page 8: ...are un cavo di alimentazione AWG12 SJT vW1 con una spina di corrente nominale superiore o uguale a 30A IL CAVO E LA SPINA DEVONO ESSERE CERTIFICATI UL O CSA N max moduli per linea diconnessione 3 x VH...

Page 9: ...doppia mentre quel rumore captato o prodotto lungo il percorso essendo presente in fase su entrambi i cavi sar annullato dall operazione di differenza Lo standard EIA RS 297 A prevede che i connettori...

Page 10: ...SH PUSH PUSH AC LOOP OUTPUT AC INPUT 13 5 220 240 V A Pwr cons 600W max 2 5A 50 60 Hz 220 240 V MADE IN ITALY CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN TO PREVENT THE RISK OF FIRE OR ELECTRIC SHOCK N...

Page 11: ...LOOPOUTCONNECTOR LINK IN IN OUT NET LINE PUSH PUSH PUSH AC LOOP OUTPUT AC INPUT 13 5 220 240 V A 100 120 V 15 A Pwr cons 600W max 2 5A 50 60 Hz 220 240 V 5 A 100 120 V 50 60 Hz MADE IN ITALY CAUTION...

Page 12: ...trollo su tutti i dispositivi posti a valle della rottura Connessione mista possibile utilizzare una struttura mista dividen do ogni cluster in sottogruppi di dispositivi Il primo dispositivo di ogni...

Page 13: ...ftware sia in stato OFFLINE in tale caso il display locale mostra la scritta Switch to local control NO YES Selezionando YES si attiva la procedura di sblocco sul display appare Push and hold for 3 se...

Page 14: ...impostazioni dell ultima ses sione di INFINITO anche se il device non connesso a INFINITO DESCRIZIONE INTERFACCIA La pagina iniziale Home del display mostra le informazioni essenziali del diffusore A...

Page 15: ...tte le funzioni controllabili ruotando la manopola si scorre l elenco in senso verticale Cliccando su una voce si accede al settaggio relativo e cliccando su EXIT ci si ritrova nel menu orizzonta le d...

Page 16: ...B AUTO ST BY OFF MEMORY CURRENT DEFAULT SERVICE SENSORS TEST EXIT HPF STATE OFF DANTE OUT ROUTING SOURCE ANALOG NOISE GATE EXIT Push button to return to main Menu DANTE RATE 48 kHz LATENCY 1 ms PCM 24...

Page 17: ...NGLE 90 SERVICE SENSORS TEST EXIT DANTE RATE 48 kHz LATENCY 1 ms PCM 24 bit STATUS NO AUDIO S 53 C 45 C 222 RST n to INFO VHA 406ND FW 1 0 0000 SENSORS HF Load VAC 222 FAN 0 EXIT TEST SERVICE MEMORY Y...

Page 18: ...erra 3 moduli su subwoofer 606 x 73 x 502mm 10 3 Kg VHA S 406 Supporto fissaggio per stativo Acciaio max 1 modulo 590 x 180 x 154mm 5 5 Kg VHA RC 406 Rain cover VHA C 406 412 Nylon cover VHA T 406 Tro...

Page 19: ...pavimenti o travi assicurarsi sempre che tutti i sistemi di aggancio e di fissaggio siano di dimensioni e di capacit di carico appropriate Tutti i diffusori appesi in teatri palasport o in altri luogh...

Page 20: ...Aggiungere ad uno ad uno i moduli con l angolazione precedentemente calcolata ed effettuare i collegamenti di rilancio audio e alimentazione Effettuare tutte le ulteriori tecniche di fissaggio necessa...

Page 21: ...T 406 Esempio di configurazione con 3 x moduli VHA 406ND 1 x base per array VHA B 406 INSTALLAZIONE STACKED possibile predisporre al massimo 4 moduli a terra e 3 moduli sopra il subwoofer tramite acc...

Page 22: ...ella posizione LOCK Ripetere lo stesso procedimento per il fissaggio tra due moduli sbloccare il pin B scegliere l angolazione desiderata da assegnare al modulo sottostante mediante la flangia graduat...

Page 23: ...A 112SND e VHA 406ND come da figura seguendo le istruzioni sull etichetta della flybar VHA 2F 406 e agganciarla alle flybar VHA f 406 STEP 2 Inserire l pin della flybar VHA 2F 406 in posizione 1 STEP...

Page 24: ...bar VHA FH 406 1 Estrarre il pin di bloccaggio D ruotandolo nella posizione UNLOCK agganciare i piedini E nella loro sede F quindi far scorrere all indietro la fly bar e poi bloccare il pin D ruotando...

Page 25: ...urezza ai moduli che fanno parte del sistema Perilfissaggioel inclinazionedelprimomoduloallabaseVHA B406 e per quello degli altri moduli procedere come descritto nelle pagine precedenti Scelto il grad...

Page 26: ...di avere un basso veloce e di grande impatto sui 60 90Hz particolarmente apprezzato in live CONFIG PRST SELECT 2 Way CONFIG PRST SELECT 3 Way PRESET SELECT 2 Way PRESET SELECT 3 Way HPF STATE ON SOUND...

Page 27: ...max peak W 1600W LF 800W HF Impedenza di ingresso kOhm 22 INGRESSI ED USCITE Ingressi e rilanci di alimentazione PowerCon IN OUT Connettori di ingresso XLR IN OUT Ingressi Uscite NET NET IN NET OUT Et...

Page 28: ......

Page 29: ...i Italy www fbt it info fbt it HORIZON VHA 406ND 406N GENERAL INFORMATIONS 29 WARNINGS 30 GENERAL FEATURES 31 Description 31 Specifications 31 DIMENSIONS 32 INPUT PANEL 33 POWER SUPPLY 34 Power supply...

Page 30: ...spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE...

Page 31: ...h plywood of 0 47 with anti scratch varnish and is provided with two handles with rubber inserts and integrated mechanics to join the spe akers and angle them from 5 to 20 in 5 steps The FBT HORIZON V...

Page 32: ...32 DIMENSIONS 612mm 24 09 397mm 15 62 360mm 14 17 20...

Page 33: ...K IN IN OUT NET LINE 1 2 VHA 406ND VHA 406N 1 XLR input 2 XLR link output 3 Port compatible with EtherCON RJ45 connectors used for Ethernet network input for remote control and monitoring via INFINITO...

Page 34: ...han24A THE CABLE AND THE PLUG MUST HOLD THE UL OR CSA CERTIFICATION N max modules for connection line 3 x VHA 406ND power cord supplied 4 x VHA 406ND POWER CORD AWG12 SJT W1 2 5A TOT CURRENT 15A TOT C...

Page 35: ...ong the path being present in phase on both cables will be cancelled by the difference operation In the three pin version it is normally used for the termination of balanced audio lines but it is ofte...

Page 36: ...AC LOOP OUTPUT AC INPUT 13 5 220 240 V A Pwr cons 600W max 2 5A 50 60 Hz 220 240 V MADE IN ITALY CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN TO PREVENT THE RISK OF FIRE OR ELECTRIC SHOCK NEVER EXPOSE...

Page 37: ...LINK IN IN OUT NET LINE PUSH PUSH PUSH AC LOOP OUTPUT AC INPUT 13 5 220 240 V A 100 120 V 15 A Pwr cons 600W max 2 5A 50 60 Hz 220 240 V 5 A 100 120 V 50 60 Hz MADE IN ITALY CAUTION RISK OF ELECTRIC S...

Page 38: ...of control on all devices located downstream of the breakage Mixed connection it is possible to use a mixed structure dividing each cluster into subgroups of devices The first device in each group is...

Page 39: ...sed to control over 100 devices in the same network with automatic assignment of the IP address Features Compatible with Windows 7 8 10 Real time monitoring of sensors vu meters transducers failure et...

Page 40: ...INFINITO INTERFACE DESCRIPTION The Home page of the display shows the essential information of the speaker ANALOG HFL DELAY 2WAY 1BOX 0 dB PEAK FAN TEMP LIMIT LIMIT 1 2 5 3 4 6 7 8 9 10 11 FAULT INDI...

Page 41: ...le functions are listed turning the knob scrolls the list vertically Clicking on an item it is possible to access the relative setting and clicking on EXIT leads to the horizontal menu where it is pos...

Page 42: ...dB AUTO ST BY OFF MEMORY CURRENT DEFAULT SERVICE SENSORS TEST EXIT HPF STATE OFF DANTE OUT ROUTING SOURCE ANALOG NOISE GATE EXIT Push button to return to main Menu DANTE RATE 48 kHz LATENCY 1 ms PCM 2...

Page 43: ...5 DISPLAY OFF TIME OUT 60 s ROTATION ANGLE 90 SERVICE SENSORS TEST EXIT DANTE RATE 48 kHz LATENCY 1 ms PCM 24 bit STATUS NO AUDIO S 53 C 45 C 222 RST n to INFO VHA 406ND FW 1 0 0000 SENSORS HF Load VA...

Page 44: ...ack 3 modules on subwoofer 606 x 73 x 502mm 10 3 Kg VHA S 406 Bracket for 1 spkr with speaker pole Steel max 1 module 590 x 180 x 154mm 5 5 Kg VHA RC 406 Rain cover VHA C 406 412 Nylon cover VHA T 406...

Page 45: ...lways make sure that all couplers and fixing elements are properly sized and have an adequate load capacity Besides the main suspension system all flying speakers in theatres indoor stadiums or in sev...

Page 46: ...al array configuration Add the modules with the previously calculated angle one by one and create the audio and power relaunch connections Perform all the additional fastening techniques necessary for...

Page 47: ...zers VHA T 406 Configuration example with 3 xVHA 406ND modules 1 x VHA B 406 base for array STACKED INSTALLATION A maximum of 4 modules on the ground and 3 modules above the subwoofer can be arranged...

Page 48: ...d fix it in the LOCK position Repeat the same procedure for fixing between two modules release the pin B choose the desired angle to assign to the module below using the sliding graduated flange C Alw...

Page 49: ...models as shown in the figure by following the instructions on the label of the VHA 2F 406 flybar and hook it to the VHA f 406 flybars STEP 2 Insert the pin of the VHA 2F 406 flybar in position 1 STE...

Page 50: ...the modules that are part of the system To fix and tilt the first module to the VHA B 406 base and to that of the other modules proceed as described in the previous pages Once the desired degree of i...

Page 51: ...d safety to the modules that are part of the system To fix and tilt the first module to the VHA B 406 base and to that of the other modules proceed as described in the previous pages Once the desired...

Page 52: ...rmance in the 75Hz 105Hz range due to the limitation of the VHA 406ND The PUNCH pre set offers a fast and high impact bass on 60 90Hz particularly suitable in live mode CONFIG PRST SELECT 2 Way CONFIG...

Page 53: ...F W 1600W LF 800W HF Input impedance kOhm 22 INPUTS OUTPUTS Power supply inputs and re links PowerCon IN OUT Input connectors XLR IN OUT Input output NET NET IN NET OUT EtherCon POWER SUPPLY AC power...

Page 54: ......

Page 55: ......

Page 56: ...FBT ELETTRONICA SPA Via Paolo Soprani 1 62019 RECANATI Italy Tel 071750591 Fax 071 7505920 email info fbt it www fbt it...

Reviews: