background image

Summary of Contents for LEGEND 7100

Page 1: ...LEGEND S E R I E S r e _ ENPAss 4 7 c 1 8 9 o n Id Owners Manual ...

Page 2: ...lity and ease of operation in mind Please take a few minutes to review the contents of this manual 0 In order to realize the full potential of this system it is important that you feel comfortable with its operation The following pages will familiarize you with the procedures for operating the LEGEND Security System Thank You FIRE BURGLARY INSTRUMENTS ...

Page 3: ...ypad Layout 3 System Operation 6 Arming 7 Stay 8 Instant 9 Instant Stay 9 Bypass 10 Forced Arming 11 Unbypass 11 Disarming 12 Keypad Emergency Conditions 13 User Definition 15 Glossary 17 Owners Information 19 About the Manufacturer 21 Additional Notes 24 2 ...

Page 4: ...ts show whether any zones are currently in alarm bypassed in trouble or faulted status Note If your system contains eight zones then only the zones labelled l 8 will be active The status of each zone is represented as follows ALARM TROUBLE Fast Blinking Slow Pulse n k BYPASSED Slow low lntenslty bllnklng NOT READY Solld ON Each light will only reflect one condition at a time If a zone contains mul...

Page 5: ...IONS FAILURE If the COM light is ON then there has been a communications error with the Central Station 6 INSTANT The INS indicator will be ON when the system has been armed in the INSTANT mode This means that the system has been activated and the entry delay has been eliminated 7 NUMERICAL SECTION The numericai section of the keypad operates similar to a calculator or typewriter The digits 0 9 ar...

Page 6: ...h the exception of interior protection This will provide exterior protection of your location while allowing full access through the location This mode would be used when arming the system and you might be walking through protected interior zones 12 BYPASS Key The BYPASS key will be used to temporarily turn off protection of a portion of your burglary protection This could be performed for example...

Page 7: ...TAY CODE USER l Function key labelled BYPASS Function key labelled INSTANT Function key labelled STAY Function key labelled CODE Entry of your four digit user code Key labelled to the left of 0 Key labelled to the right of 0 Indicates the simultaneous entry of two keys For example 3 indicates that the and 3 keys should be pressed at the same time 6 ...

Page 8: ...ime period known as the exit delay SYSTEM NOT READY If the system is not ready to be armed the READY indicator will be OFF The zone indicator lights will display the zones which are currently not ready The condition of each zone indicator reflects what the status of each zone as follows ALARM Fast blinking BYPASS Slow blinking low Intensity TROUBLE Slow pulse NOT READY Solld ON In order to make th...

Page 9: ...tion The STAY mode will deactivate any interior protection zones which means that you will be free to walk throughout your location without activating the alarm system In order to enter the STAY mode the system must be READY see previous description STAY PROCEDURE STAY USER Depress the STAY key followed by your user code After a sucessful STAY arming the ARMED and STAY indicator will be lit In the...

Page 10: ...ndicators will be lit Note The INSTANT option will automatically be reset after the system is disarmed INSTANT STAY The INSTANT STAY mode will arm the system with the characteristics of both the INSTANT and STAYmodes The system will be armed with the interior portions bypassed and the entry delay will be suspended The system must be READY in order to enter this mode PROCEDURE INSTANT STAY USER STA...

Page 11: ... 04 BYPASS 12 The sequence displayed above would have bypassed zones 2 4 and 12 Zones can be bypassed if the user performing the bypass is authorized to perform bypasses and the zone has been defined by your installer as bypassable if the zone has already been bypassed the sequence will unbypass the zone except if the system is armed and the unbypassed zone is still not ready Unbypass means that t...

Page 12: ...d a long interrupted beep will follow Following a sucessful forced arming the ARMED indicator will be lit If you are leaving the premise you may exit through an t exit entry door for the duration known as the exit entry delay Note You have just ARMED the system and the bypassed portions of your system remain unprotected UNBYPASS The UNBYPASS function removes an existing bypass from a currently byp...

Page 13: ...m troubles have taken place since the initial system arming they will appear on the display The conditions that have occurred appear in the zone display section of the keypad Each indicator light reflects the status of each zone as follows ALARM Fast bllnklng TROUBLE Slow pulse BYPASS Slow low lntenslty bllnklng NOT READ Solld ON If an intrusion has taken place white you were away do not enter unt...

Page 14: ...d can be used for conditiohs such as PANIC FIRE or MEDICAL Emergency These conditions can be programmed by your installer to suit your needs The keypad emergency conditions are active 24 hours a day whether the system is armed or disarmed For example if keypad emergency condition 1 has been defined by your installer as a PANIC then an emergency panic signal can be sent by hitting the and keys at t...

Page 15: ...r entry of a valid user code with the last digit altered by one For example if there is a valid user code of 1234 then duress codes of 1233 or 1232 exist for that user Upon entry of the duress code the system will disarm in a normal fashion and optionally transmit the duress signal to the Central Station NOTE The DURESS capability is only available if activated by your installer Please contact you...

Page 16: ...user numbers range from 01 to 16 USER ID Four digit code 0000 9999 entered at the keypad to use the Security System Each separate user must be assigned a unique user code The user ID has been displayed as USER throughout this manual AUTHORIZATION LEVEL The LEGEND control panel contains authorization levels to control the users permitted to perform various system functions This allows users to be r...

Page 17: ...nformation is entered twice for validation purposes USER DEFINITION CAN ONLY BE PERFORMED BY A USER WITH A LEVEL ONE AUTHORITY Example To create user number 3 with a user access code of 4567 and a user level of 2 enter CODE USER 03 03 4567 4567 2 2 Any error detected during the USER definition process will cause the keypad to beep rapidly four times If an error is detected retry the entlre command...

Page 18: ...igitally encoded message over your telephone line to a professional organization that monitors alarm systems The Central Station will receive the signal from your system and take the appropriate action If your Security System has been connected to a Central Station there is a nominal monthly fee for this service For further information please contact your Installing Company CONTROL PANEL The contr...

Page 19: ...sarming and other control functions to the LEGEND Security System The keypad will display the current system status and appears similar to a calculator Your security system can contain more than one keypad STAY Arms the security system when you and your family are home In the STAY mode any interior protection will be disabled allowing your family to walk freely throughout your home without activat...

Page 20: ...RESS CITY STATk ZIP TELEPHONE NUMBER Date of Installation EMERGENCY NUMBERS CENTRAL STATION FIRE DEPARTMENT POLICE DEPARTMENT NEIGHBOR GAS ELECTRIC DEPT DOCTOR HOSPITAL EMERGENCY SERVICE INFORMATION ALARM INSTALLING COMPANY c 19 ...

Page 21: ...lectronic and computer technology Thorough testing by computer as well as quality control experts has occured several times during the manufacturing process Fire Burglary Instruments warranties its products through your installing company Product Reliability and Ease of Operation are two of the major factors in the engineering design of all Fire Burglary products You can look foward to many years ...

Page 22: ..._ 1_ I 100 Engineers Road Hauppauge New York 11788 516 582 6161 w 800 645 5430 An FBX Company l 2344 Jan 89 ...

Reviews: