Summary of Contents for Star XL 4800 EZ

Page 1: ...STAR XL 4800 EZ Hookup and Installation Instructions An FBXCompany 100 Engineers Road Hauppauge NY 71788 516 582 6161 800 645 5430 ...

Page 2: ...eet from the control panel using 22 gauge wire For example if one keypad is 500 feet from the control panel with another keypad run 200 feet from the first keypad this wire run would be considered 1200 feet 500 to first keypad 700 to second keypad The available keypad power from connections 13 and 16 is restricted to 250 ma Since each keypad draws approximately 60 ma a maximum of 4 keypads can obt...

Page 3: ...of the programming information within the system To perform a panel reset remove all power from the panel and short TP2 and TP3 for at least two seconds while reapplying power The ground start pin can be used to activate an external ground start relay such as the FBI1 model 117 Ground Start module for applications which require ground start capabilities LINE SEIZURE This post is active when line s...

Page 4: ...d of 5 seconds the fire zone will not be scanned allowing the smoke detectors to settle Future violations within a two minute period will resuft in a fire alarm condition pulsing bell output immediate transmission to the CSI TRANSFORME usino 16AW ___ ___ R Connect the 16 5VAC 40VA transformer to terminals 36 and 37 G wire at 15 feet maximum to an unswltched 120 VAC out Do not use any other transfo...

Page 5: ...pad which identifies the keypad to the control panel This switch contains 4 locations numbered SW1 SW4 and is physically located behind the left hand plastic cover of the keypad To access this switch remove the cover plate by prying the cover open using a screwdriver as shown in the keypad mounting section An XL4800 installation can contain a total of eight keypads 4 LED and 4 LCD Each keypad must...

Page 6: ...which terminates the time set command EXAMPLE Current time 5 52 PM on July 31 1988 CODE Installer Code 2 0 88 07 31 17 52 NOTE The time can be entered through either an LCD or LED keypad The LCD keypad will display questions for entry of each of the values On the LCD keypad only display of the current time can be performed through depression of the key instead of the 0 key in the sequence 3 WALK T...

Page 7: ...mergency conditions pz keypad condition 1 4 p partition ALARM Zone zn p Zone alarm zn actual zone p partition TROUBLE zn p Trouble condition zn actual zone p partition BYPASS us zn p Bypass us user performing the bypass zn zone bypassed p partition RESTORE 2 zn p Restore of zone zn actual zone p partition SYS TRBL System trouble such as AC loss Low Battery or System Error SYS RSTR System restore o...

Page 8: ...R DEFINITION CODE USERl US tl US l USIDlHJSIDl LEVlILEVl MULTI PARTITION 0 USER p QUICK ARM l TIME DATE SET 3OYYMMDDHHMM ZONE DIRECTORY 4 CHIME MODE 6 INSTALLER FUNCTIONS PROCEDURE KEYPAD PROGRAMMING EXIT PROG MODE TIME DATE SETUP WALK TEST w o BELL WALK TEST with BELL DEFAULT RESET SYSTEM LOG VIEW LCD Keypad Only KEYPAD EMERGENCY CONDITIONS KEY SEQUENCE CODE INSTALLER CODE1 1 Together CODE INSTAL...