5
Place a large container under the dispensing valve and drain the barrel. Activating the beater motor will facilitate
draining the barrel when near empty. Deactivate the solution solenoid when the syrup lines have been purged.
Continue purging the barrel and then deactivate the CO
2
solenoid when the barrel has been emptied.
6
Take an empty BIB and cut off the connector. Attach the BIB connector to the connector on the syrup line – this will
open up the syrup line connector and allow for cleaning solution to be pumped into the dispenser.
7
Turn off the water supply at the solution module using the shutoff valve. DO NOT disconnect water lines from the
dispenser. This action prevents contamination.
8 Place the syrup BIB connector with adapter in the sanitizing solution.
9
Activate the solution solenoid and begin filling the barrel with sanitizing solution. Pull the relief valve as necessary
to vent the pressure allowing the fill process to continue. Deactivate the solution solenoid when the barrel is 3/4 full.
10 Activate the beater motor and agitate for three minutes.
11 While the beater motor is agitating, dispense some sanitizing solution from both the relief valve and the sample valve
to ensure the valves are sanitized as well.
12 Remove the BIB connector from the sanitizing solution and reconnect to the syrup supply.
13 Activate the solution solenoid.
14
Place a large container under the dispensing valve and drain the barrel. Activating the beater motor will facilitate
draining the barrel. Deactivate the solution solenoid when the syrup lines have been primed with syrup. Continue
purging the barrel and then deactivate the CO
2
solenoid when the barrel has been emptied.
15 Restore the water supply.
16 Activate the solution solenoid and beater motor again. When the barrel is 1/2 full, deactivate the solution solenoid
to stop the fill process.
17 Activate the CO
2
solenoid and drain the barrel. This step removes the remaining sanitizing solution left in the barrel.
Deactivate the CO
2
solenoid and beater motor when the barrel is empty.
18 Navigate to the MAINTENANCE MENU and start the FILL BARREL process. Follow the prompts until the barrel is
full.
19
If any sanitizer off-taste remains then drain the barrel again and refill.