n
When using steam cleaning equipment cover control unit,
cable plugs, all other electrical connections and the generator
beforehand and do not expose these items to the direct steam
jet.
n
Electrical plug connections must be plugged in during jet
cleaning.
n
Remove loose parts (e.g. paint scales that may have come off
during assembly work) with an industrial vacuum cleaner or
any means of extraction.
n
Vacuum cleaning equipment must generally be used for
cleaning when the fuel system is open.
n
Perform work on the fuel system only in a clean environment
(no dust, no grinding or welding work). Avoid draughts (dust).
The workshop floor must be cleaned at regular intervals. No
brake or power test stand should be present or operated in the
same room.
n
Air movements, which could swirl up dust, such as brake
repairs or starting of engines, must be strictly avoided.
n
For work, such as the removal and assembly of defective com-
ponents on the Common Rail System, it is highly recom-
mended to cordon off a dedicated area in the workshop. This
area must be spatially separated from other areas (which are
used for general vehicle repairs, like brake repairs)
n
No general machine tools should be operated in this room.
n
Periodic cleaning of this workshop area is obligatory, draughts,
ventilation system and heating blowers must be minimized.
n
Engine compartment area where dirt particles could come
loose, should be covered with new, clean foil.
n
Working means and tools must be cleaned before being used
for work. Use only tools without damaged chromium coating, or
tools without chromium coating.
n
Wear clean working clothes.
n
Use only lint-free cleaning cloths for work in the fuel system.
n
Remove loose parts (e.g. paint scales that may have come off
during assembly work) with an industrial vacuum cleaner or
any means of extraction. Vacuum cleaning equipment must
generally be used for cleaning when the fuel system is open.
n
Working means and tools must be cleaned before being used
for work. Use only tools without damaged chromium coating, or
tools without chromium coating.
n
Do not use any previously used cleaning or testing fluids for
cleaning.
n
The use of compressed air for cleaning is prohibited when the
fuel system is open.
n
Work on disassembled components must only be carried out at
a specially furnished work place.
n
When removing or assembling components you should not use
any materials from which particles or fibres could flake off
(cardboard, wood, towels).
n
Dismantled parts must only be wiped off with clean, lint-free
cloths if required. No dirt particles must be wiped into the com-
ponents.
Notes and measures to be applied
during work in the fuel system
General – Maintenance and repair
BW 226 BVC-5 / BW 226 DI-5
44
Summary of Contents for BOMAG BW 226 BVC-5
Page 2: ...2 Find manuals at https best manuals com...
Page 8: ...Table of contents BW 226 BVC 5 BW 226 DI 5 8 Find manuals at https best manuals com...
Page 9: ...1 General General BW 226 BVC 5 BW 226 DI 5 9 Find manuals at https best manuals com...
Page 32: ...B 586 0365 Fig 7 General Concerning your safety BW 226 BVC 5 BW 226 DI 5 32...
Page 33: ...B 586 0366 Fig 8 General Concerning your safety BW 226 BVC 5 BW 226 DI 5 33...
Page 51: ...This as a preview PDF file from best manuals com Download full PDF manual at best manuals com...