2.1 Programming parameters
CONFIGURATION TABLE
Parameter name
Parameter description
Limits
Credit currency
P0.4
Monetary value desired (EURO, EUR, €, USD, $, £, Coin, etc.).
Max 4 characters
Base amount
P0.5
Set the amount to deduct from the prepaid card.
Min=0000.00
Max=9999.99
Accumulation
of time
P0.6
If enabled, the duration of service will be prolonged and credit deducted by
placing the card near the reader area again.
0=NO
1=YES
Start warning
notice
P0.7
Allows for the supplementary output to be used in order to warn that service is
about to end; the programmed time indicates the start of the warning notice for
end of service.
Min=00m00s
Max=99m59s
Duration of
warning notice
P0.8
Set the duration of the automatic notice of end of service.
Min=00m00s
Max=99m59s
Volume of
sound
P0.10 Indicate the volume of the internal buzzer: 0=OFF, 1=low, 2=medium, 3=high.
Min=0
Max=3
System code
P0.11
The system code allows you to protect the system from cards not belonging to
the same system. The system code programmed in the CT02 must be the same
as that memorized in the prepaid cards and in the
CARDWRITER-01
programmer, otherwise the cards will be refused.
For more information, consult the instruction manual of the
CARDWRITER-01
programmer.
Min=00000
Max=99999
Log file
Log
If enabled, once the USB stick has been inserted into the CT02, a “
CTLOG.TXT
”
file will be created which contains a register of the total credit inserted in the
system.
0=NO
1=YES
Base time
P1.2
Set the duration of service.
Min=00h00m00s
Max=23h59m59s
Manual pause
duration
P1.3
This is the time of the pause which can be utilized by the user of the service. It
can be divided into more than one period. If other than 0, the service
automatically starts in pause mode and is activatedat the end of the pause time
established or upon pressing the start/pause button.
For each service available a start/pause button can be connected to the CT02.
This is for activating a service or for placing a service in pause up to the
maximum time established.
It will be used as a delayed start for services which are not supplied with
start/pause buttons.
Min=00m00s
Max=99m59s
Automatic
pause start
P1.4
The automatic pause allows for the CT02 service to be interrupted for a certain
amount of time. It can be used as a warning notice for the end of service, or for
allowing time to lather in showers not supplied with start/pause buttons.
This parameter indicates the precise moment of activation of the automatic
pause before the service end time.
Min=00m00s
Max=99m59s
Automatic
pause duration
P1.5
Set the duration of automatic pause.
Min=00m00s
Max=99m59s
WARNING: only modify the parameter values which come after the “=” sign.