3
5.
3502-SE2P
77
6,4
65
1 2 3
4 5
6
7 8
3
26
X1
X2
1
1
8
8
3,2
64
±
1
C1
F1
R13
R20
X3
X4
1
4
C7
X5
1
2
5
6
3.
4.
Specifications subject to change without notice
Technical data
Dimensions and weight
Figure 2
Dimensions
length
77 mm
width
65 mm
height
26 mm
Weight
100 g
Scale reduced
1)
Analog speed command may be set by an external potentiometer or an external voltage.
2)
The maximum controllable speed depends on the gain of the Servo Amplifier,
the power supply, the motor type and the load.
3)
The minimum controllable speed depends on the motor type and the load.
Power Stage:
– Power supply
– Total output voltage drop (I
motor
=2A)
Switching frequency
Current limit (pulse-by-pulse current limiting)
Analog speed command:
1)
– Voltage range
– Input resistance
– Frequency bandwidth
Logic inputs
Output voltage for external use (max. load 50 mA)
Total standby current without encoder
(Hall sensors supply included)
Maximum controllable speed with Hall sensor
2)
Minimum controllable speed with Hall sensor
3)
Minimum controllable speed with encoder
3)
Temperature range:
– Operating temperature
– Storage temperature
Power supply
Logic and analog inputs
Continuous output current @ T
A
= 22
°
C
Maximum ratings
Specific characteristics
35
V DC
-0,3 to +10
V DC
1,5
A
12
÷
35
V DC
3,8
V DC
25
kHz
3
A
0
÷
5
V DC
36
k
Ω
117
Hz
TTL
5,5
V DC
55
mA
60 000
rpm
1 000
rpm
100
rpm
0 ... + 70
°
C
–20 ... + 80
°
C