4 Trace
15-04-2016 34 7000.05052
4.1.3
Typical execution of the trace function
1.
Set the trigger type and the type of the data sources (2370.04).
2.
Set the trigger source and the signals to be recorded (2370.01, 07 to 0A).
3.
Set the recording length (2370.05).
4.
If necessary Set the sampling rate (2370.06).
5.
Set the threshold value (2370.02) for the trigger.
6.
Set the flank for the trigger and activate recording (2370.04).
This completes the settings for the trace recorder.
7.
Test the trigger status (2371.01) at the value 3.
8.
Read the recorded content of the buffer (2371.02 to 05).