Communications settings
42
5.2
Setting the node number via the object dictionary
As an alternative to the LSS method via the CAN network, the node number can also be set
via any interface (CAN, USB, RS232) available on the drive.
The setting is performed by writing the object 0x2400.03 in the object dictionary:
Tab. 20: CAN baud rate index and node number
The object 0x2400.01 can be used to read the current setting of the baud rate (AutoBaud or
fixed baud rate).
A change of the node number via the object 0x2400.03 is acknowledged with the last node
number. The changed node number is not loaded until a Save command has been executed
for the application parameters followed by a Reset command.
Index
Subindex Name
Type Attr.
Default value
Meaning
0x2400 0x00
Number of Entries
U8
ro
8
Number of object entries
0x01
CAN Rate
U8
rw
9
Index of the CAN baud rate according to
Tab. 19
0x03
Node ID
U8
rw
1
Node number