11
3 Installation
Assembly
3.1
The servomotor must be installed according to certain specifications to prevent malfunctions and
damage.
CAUTION!
Material damage
Incorrect installation or installation with the wrong fixing materials can cause irreparable damage to
the motor's function and / or damage the motor.
Observe the following assembly instructions.
f
Use environment
Depending on its use, the servomotor can get very hot. Appropriate heat dissipation possibilities
must be provided.
Shaft loads
When pressing parts on the motor shaft it must be held against on the opposite side. Otherwise the
maximum allowable load values (axial at a standstill) must be noted and observed. See
section 7
"Technical Data"
.
Mounting flange
When fixing the servomotor to the front flange, the screws must be locked as they can loosen
at high temperatures. The maximum length of the fixing screws must be noted and observed as
otherwise the motor will be destroyed. The depth of engagement in the motor may not exceed be
exceeded. See
section 7 "Technical Data"
.
The maximum tightening torques are usually limited by the strength of the screws. However, they
may not exceed the data given in
section 7 "Technical Data"
.
Right
The motor is fixed by the screws on the
mounting flange.
Wrong
The motor is securely clamped to the attach-
ment with a U-bolt.
Electrical connection
It is necessary to ensure that the ribbon cable is laid without risk of damage during installation and
operation, e.g. through chafing, squeezing or too small bending radii. The maximum load of the
cable must be noted and observed. See
section 7 "Technical Data"
.