3

4

5 6

1

2

 

W

H

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W  128.0 mm 

H  102.0 mm 

D  38.1 mm 

 

2.  

 

 

 

 

 

 

 

 

 

 

 

 

Power Indicator Light

Mounting Hole

Power Connector

COM1/COM2 DB-9

Male Connector
USB Connector

Mini USB Connector

Part Names and Dimensions

 

Summary of Contents for P2043S

Page 1: ...nel is damaged avoid contact with the leaked liquid crystal If the liquid crystal spills on clothing or skin use soap and wash off thoroughly In case of eye contact the liquid hold the eye open flush with plenty water and get medical attention as soon as possible Do not touch any terminals while the power is on Otherwise it may cause injury due to electrical shock Disconnect the power supply befor...

Page 2: ...it Other equipment 1 3 Operation Do not use sharp objects or excessive force to press the touch screen This may damage the touch screen Do not use the output signal of the device as any safety function or system emergency stop It may result in personal injury or equipment damage if a malfunction of the touch occurs 1 4 Maintenance and Service The agreed guarantee applies Only qualified personnel s...

Page 3: ...3 3 4 5 6 1 2 W H D W 128 0 mm H 102 0 mm D 38 1 mm 2 Power Indicator Light Mounting Hole Power Connector COM1 COM2 DB 9 Male Connector USB Connector Mini USB Connector Part Names and Dimensions ...

Page 4: ...trial Professional Commercial Equipment class Class III Equipment type Permanently connected Fixed I O Port Serial 1 Connector D Sub 9 Pin COM1 RS 232 TXD RXD COM2 RS 422 485 Choose one for usage Serial 2 LAN USB USB2 0 Type A Host x1 USB2 0 Type mini B Device x1 Micro SD Audio PLC Extension Termination Switch Power Power Input 24VDC 20 Consumption 280mA 24VDC Insulation 50MΩ at 500VDC Environment...

Page 5: ...ring contacts the plate Insert a hook into each mounting hole on the HMI and then tighten the screws evently with a moderate torque Failure to tighten the screws may cause the HMI to fall malfunction or short circuit Excessive tightening may cause deformation The necessary torque is about 0 16N m 5 Unpacking the Unit Installation Procedures ...

Page 6: ...und wire as short as possible 7 DB 9 Male Connector PIN COM1 RS 232 COM2 RS 422 COM2 RS 485 1 NC 1 TX DATA 2 RX NC NC 3 TX NC NC 4 NC RX NC 5 GND GND GND 6 NC TX DATA 7 NC NC NC 8 NC NC NC 9 NC RX NC 1 NC No Connection 6 DC24V FG Power Connection Pin out of COM Ports Use 22 12 AWG 0 5 1 5 mm wire for the power connections 2 ...

Page 7: ...92 FAX 886 2 2809 2618 E mail sales fatek com tech fatek com Website www fatek com R AUTOMATION CORPORATION 26FL NO 29 SEC 2 JUNGJENG E RD DANSHUEI DIST NEW TAIPEI CITY 25170 TAIWAN R O C 7 Last modified date 01 03 2017 ...

Reviews: