H 1 - 7  

Module Name 

Specifications 

Peripheral and A

ccessory 

RFID Card 

CARD-H 

Read / Write wireless card (for FBs-DAP-BR/CR and FBs-PEPR) 

Programming 

Devices 

FP-08 

FBs- Series PLC handheld programmer 

Winproladder 

FATEK-PLC Winproladder Programming software 

Memory Pack 

FBs-PACK 

FBs-PLC program memory pack with 20K Words program, 20K Words register, write protection switch 

PWMDA module  PWMDA 

10-bit single channel pulse width modulation(PWM) 0~10V analog output (AO) module   

USB- RS232 

Converter Cable 

FBs-U2C-MD-180 

Communication converter cable with standard USB AM connector to RS232 MD4M connector (used in 

standard PC USB to FBs main unit Port 0 RS232), length 180cm 

Communication 

cables 

FBs-232P0-9F-150 

MD4M to DB9F communication cable (FBs main unit Port 0 RS232 connect to standard DB9M), length 

150cm 

FBs-232P0-9M-400 

MD4M to DB9M communication cable (FBs main unit Port 0 RS232 connect to DB9F), length 400cm 

FBs-232P0-MD-200 

MD4M to MD4M communication cable (FBs main unit Port 0 RS232 connect to FBs-PEP/PEPR), length 

200cm 

FBs-232P0-MDR-200 

MD4M to 90

˚

 MD4M communication cable (FBs main unit Port 0 RS232 connect to FBs-PEP/PEPR), 

length 200cm 

High density DIO 

cable 

HD30-22AWG-200 

High density modules(FBs-24X, FBs-24YT/J, FBs-32DGI) connector

30pin Socket, 22AWG I/O cable, 

length200cm 

16/7-Segment 

LED display 

DBAN.8-nR 

0.8” 4-digit 16-segment LED display, n means R(Red) 16-segment LED characters display installed, 
can be 1~4 

DBAN.2.3-nR 

2.3” 4-digit 16-segment LED display, n means R(Red) 16-segment LED characters display installed,   
can be 1~4 

DB.56-nR 

0.56" 8-digit 7-segment display, n means R(Red) 7-segment LED characters display installed,   
can be 1~8 

DB.8-nR 

0.8" 8-digit 7-segment display, n means R(Red) 7-segment LED characters display installed, can be 1~8 

DB2.3-nR 

2.3" 8-digit 7-segment display, n means R(Red) 7-segment LED characters display installed, can be 1~8 

DB4.0-nR 

4.0" 4-digit 7-segment display, n means R(Red) 7-segment LED characters display installed, can be 1~4 

Training Box 

FBs-TBOX 

46cm x 32 cm x 16cm suitcase, containing FBs-24MCT main unit. FBs-CM25E communication module 

(RS232 + RS485 + Ethernet network), 14 simulated input switches, 10 external relay output, Doctor 
terminal outlet I/O, peripherals such as stepping motor, encoder, 7-segment display, 10 of 10mm LED 
indicator, thumbwheel switch, and 16 key keyboard. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. 

 

Relay output

 

Transistor SINK(NPN) output

 J 

 

Transistor SOURCE (PNP) output 

2.   

 

built-in RS232 port

 

built-in USB port (non-standard) 

3.   

AC 

 100~240VAC power supply

 D12 

 

12VDC power supply

D24 

 24VDC power supply 

4.  –C

Blank 

 

Standard

–C 

 

add in RTC 

5.    The unmarked frequencies of Digital Input (DI) or Digital Output (DO) are low speed. 

 

Summary of Contents for FBs-1HLC

Page 1: ...al I O Expansion Unit H1 13 1 7 4 Digital I O Expansion Module H1 14 1 7 5 High Density Digital I O Expansion Module H1 15 1 7 6 Numeric I O Expansion Module H1 15 1 7 7 Analog I O Expansion Module H1 15 1 7 8 Temperature Input Module H1 16 1 7 9 AI AO Temperature Combo Module H1 17 1 7 10 Expansion Power Module H1 17 1 7 11 Voice Output Module H1 17 1 7 12 Potential Meter Module H1 17 1 7 13 Load...

Page 2: ...on and Wiring H4 6 Chapter 5 Power Supply Wiring Power Consumption Calculation and Power Sequence Requirements 5 1 Specifications and Wiring of AC Power Sourced Power Supply H5 1 5 2 Specifications and Wiring of DC Power Sourced Power Supply H5 2 5 3 Residual Capacity of Main Expansion Unit and Current Consumption of Expansion Module H5 4 5 3 1 Residual Capacity of Main Expansion Unit H5 4 5 3 2 M...

Page 3: ... up the Single End Transistor Output Circuit only applicable to high and medium speed H7 6 7 5 Output Device Protection and Noise Suppression in DO Circuit H7 6 7 5 1 Protection of Relay Contacts and Noise Suppression H7 6 7 5 2 Protection of Transistor Output and Noise Suppression H7 8 Chapter 8 Test Run Monitoring and Maintenance 8 1 Inspection After Wiring and Before First Time Power on H8 1 8 ...

Page 4: ...for illustration OUT Y Y6 Y1 AC100 240V C0 Y0 Y4 Y2 C2 Y3 PORT0 Y5 C4 C6 0 4 8 2 I 6 5 9 Y8 Y7 Y9 3 7 IN X X8 X0 PROGRAMMABLE CONTROLLER 24V OUT S S RX TX RUN ERR I2 I3 POW X4 X2 X1 X3 0 8 4 2 I I0 9 6 5 X6 X5 X7 X12 3 II 7 X10 X9 X11 X13 X10 3 I 2 0 Y2 AC100 240V C0 Y1 Y0 C2 8 Y4 Y3 C4 Y5 Y6 C6 Y7 9 5 6 4 7 X2 TX 24V OUT S S X0 X1 IN X RX ERR OUT Y POW RUN 0 X3 X5 X4 X7 X6 X9 X8 Y8 Y9 X12 X11 X13...

Page 5: ...ation board for 7 types CB of CB2 CB22 CB5 CB55 CB25 CBE CBCAN 3 types AIO of B2DA B2AD B4AD and 2 types DAP of BDAP and BPEP 17 Left side communication expansion header only available in MC MN model for CM22 CM25 CM55 CM25E CM55E and CMGSM connection 18 Connector for Memory Pack 19 Connector for built in communication port Port 0 With USB and RS232 optional shown in the figure is for RS232 20 Rig...

Page 6: ...tput expansion slot with cover plate removed FBs 16XYR Output expansion slot cover plate z Expansion module with 40mm width case 8XY 8Y 8X 6AD 2DA 4DA 4A2D 2A4TC 2A4RTD 7SG1 7SG2 2TC 6TC 6RTD CM5H 6NTC 4PT 1LC 1HLC VOM Screw hole ψ4 5 2 Expansion cable connector Output status indicator Input status indicator DIN RAIL tab I O terminal block POW OUT Y C1 Y1 I 2 Y3 C3 Y2 Y4 4 3 X2 2 I S S X1 X4 4 3 I...

Page 7: ...earance of Communication Expansion Module The Communication Module CM of FBS PLC has a 25mm width case which can be used in the following seven modules CM22 CM25 CM55 CM25E CM55E CM25C CM5R 螺絲固定孔 ψ4 5 2 通訊模組擴充扁平排線接頭 插於主機之通訊模組連接插座 Port3 通訊指示燈 Port4 通訊插座 Port3 通訊插座 Port4 通訊指示燈 17 DIN RAIL卡鉤 FBs CM25E PORT3 RS232 RX TX N T TX TX RX RX RUN LNK 乙太網路 Port4 Terminator 附加開關 T ON N OFF G 6 2 1 3 ETHERNET P...

Page 8: ...eed total 5KHz 10 points relay or transistor output 4 points high speed 200KHz 4 points medium sped 20KHz 1 RS232 or USB port expandable up to 5 built in RTC detachable terminal block FBs 32MC 20 points 24VDC digital input 6 points high speed 200KHz 2 points medium speed 20KHz 8 points medium speed total 5KHz 12 points relay or transistor output 6 points high speed 200KHz 2 points medium speed 20K...

Page 9: ...munication module FBs CM55 2 ports RS485 Port3 Port 4 communication module FBs CM25 1 port RS232 Port3 1 port RS485 port 4 communication module FBs CM25E 1 port RS232 Port3 1 port RS485 port 4 Ethernet network interface communication module FBs CM55E 1 port RS485 Port3 1 port RS485 port 4 Ethernet network interface communication module FBs CMZB ZigBee communication module FBs CMZBR ZigBee communic...

Page 10: ...s 32DGI connector 30pin Socket 22AWG I O cable length200cm 16 7 Segment LED display DBAN 8 nR 0 8 4 digit 16 segment LED display n means R Red 16 segment LED characters display installed can be 1 4 DBAN 2 3 nR 2 3 4 digit 16 segment LED display n means R Red 16 segment LED characters display installed can be 1 4 DB 56 nR 0 56 8 digit 7 segment display n means R Red 7 segment LED characters display...

Page 11: ...n retentive C140 C199 60 Can be configured as retentive type 32 Bit Retentive C200 C239 40 Can be configured as non retentive type Non retentive C240 C255 16 Can be configured as retentive type HR DR Data Register Retentive R0 R2999 3000 Can be configured as non retentive type D0 D3999 4000 Non retentive R3000 R3839 840 Can be configured as retentive type HR ROR Retentive R5000 R8071 3072 When not...

Page 12: ...84 32KHz with 1 resolution Captured input Points Max 36 points all of main units have the feature 10μS super high speed high speed input Captured pulse width 47μS medium speed input 470μS mid low speed input Setting of Digital Filter X0 X15 Frequency 14KHz 1 8MHz Chosen by frequency at high frequencies Tine constant 0 1 5mS 0 15mS adjustable by step of 0 1mS 1mS Chosen by time constant at low freq...

Page 13: ...S S 24V OUT X0 Y8 Y10 Y6 Y4 Y3 Y2 Y1 Y2 SG0 Y3 C4 Y5 Y7 C8 Y9 Y11 X1 X1 X2 X4 X4 X3 X5 X6 X5 X8 X7 X9 X10 X11 X12 X16 X13 X14 X15 X18 X17 X19 FBS 32MN D24 D12 max 400mA IN 24VDC 12VDC z 44 point digital I O main unit 28 points IN 16 points OUT X19 Y11 Y10 Y8 Y6 Y7 Y4 Y5 Y3 Y2 Y0 Y1 Y4 Y0 Y1 SG0 Y3 Y2 Y7 SG4 Y5 Y6 C8 Y9 X7 AC100 240V X1 24V OUT S S X0 X0 X1 X4 X2 X3 X4 X5 X5 X6 X12 X9 X8 X8 X9 X11 ...

Page 14: ... FBS 14MC D24 D12 IN 400mA max 24VDC 12VDC z 20 point digital I O main unit 12 points IN 8 points OUT AC Power DC Power AC100 240V C0 Y1 Y0 Y2 C2 Y4 Y3 Y6 Y5 C4 C6 Y7 24V OUT S S X0 X2 X1 X4 X3 X8 X6 X5 X7 X10 X9 X11 IN 400mA max FBS 20MA AC FBS 20MC AC C0 Y1 Y0 Y2 C2 Y4 Y3 Y6 Y5 C4 C6 Y7 24V OUT S S X0 X2 X1 X4 X3 X8 X6 X5 X7 X10 X9 X11 FBS 20MA D24 D12 FBS 20MC D24 D12 IN 400mA max 24VDC 12VDC z...

Page 15: ...BS 40MC AC X21 Y15 C4 C0 C2 Y0 Y1 Y3 Y2 Y4 Y9 Y7 C6 Y5 Y6 C8 Y8 C12 Y11 Y10 Y13 Y12 Y14 X5 24V OUT S S X1 X0 X3 X2 X4 X13 X9 X7 X6 X8 X11 X10 X12 X17 X15 X14 X16 X19 X18 X20 X23 X22 FBS 40MA D24 D12 FBS 40MB D24 D12 FBS 40MC D24 D12 IN 400mA max 24VDC 12VDC z 60 point digital I O main unit 36 points IN 24 points OUT AC Power DC Power 24V OUT X28 X12 Y8 Y4 Y1 Y0 C0 AC100 240V C2 Y3 Y2 Y6 C4 C6 Y5 C...

Page 16: ...4 C7 C5 Y6 Y8 Y7 S S 24V OUT X5 X1 X4 X2 X3 X8 X6 X7 X10 X9 X11 Y11 Y9 C9 Y10 Y12 C13 Y16 Y14 Y13 Y15 X19 X15 X14 X13 X16 X18 X17 X22 X20 X21 X24 X23 FBS 40XY D24 D12 IN 400mA max 24VDC 12VDC z 60 point I O expansion unit 36 points IN 24 points OUT AC Power DC Power X20 Y14 C5 AC100 240V C1 Y3 Y2 Y1 C3 Y4 Y5 Y9 Y8 C7 Y6 Y7 C9 Y11 Y10 Y12 C13 Y13 24V OUT S S X3 X1 X2 X5 X4 X6 X10 X9 X7 X8 X11 X13 X...

Page 17: ...11 Y12 Y15 Y13 C13 Y14 Y16 Y1 C1 Y2 C3 Y3 Y6 C5 Y4 Y5 Y7 Y8 FBS 16Y z 24 point digital I O module 14 points IN 10 points OUT Y1 C1 Y2 C7 C5 Y4 C3 Y3 Y5 Y6 Y7 S S X1 X2 X3 X4 X5 X6 X7 X8 X9 Y10 Y8 Y9 X10 X11 X12 X13 X14 FBS 24XY z 40 point digital I O module 24 points IN 16 points OUT X20 Y14 C5 C1 Y3 Y2 Y1 C3 Y4 Y5 Y9 Y8 C7 Y6 Y7 C9 Y11 Y10 Y12 C13 Y13 S S X3 X2 X1 X6 X4 X5 X13 X10 X8 X7 X9 X12 X1...

Page 18: ...1 Y13 Y15 V2 Y17 Y19 Y21 Y23 V3 FBS 24YJ 2 54mm Header connector z 7 segment LED display module 8 digits 7SG1 16 digits 7SG2 16 pin 2 54mm Header connector CH1 CH0 FBS 7SG1 2 z Thumbwheel switch multiplex input module 4 digits 8 30Pin 2 54mm Header connector FBS 32DGI 24V NC S2 S4 S6 S8 D1 D3 D5 D7 D9 D11 D13 D15 NC FG 24V S1 S3 S5 S7 D0 D2 D4 D6 D8 D10 D12 D14 NC I 2 30 29 7 62mm fixed terminal b...

Page 19: ... T0 T2 T3 T5 T1 FBS 6TC z 16 channel thermocouple input module T0 T1 T2 T3 T4 T5 T6 T6 T5 T4 T3 T2 T1 T0 T7 T7 T8 T8 T9 T10 T11 T12 T13 T13 T12 T11 T10 T9 T14 T15 T14 T15 FBS 16TC z 6 channel RTD input module P4 P2 P2 P3 P3 P4 P5 P5 P0 COM P0 P1 P1 FBS 6RTD R4 R0 R2 R2 R3 R3 R1 R5 R5 R4 R1 R0 FBS 6NTC z 16 channel RTD input module P0 P1 P2 P3 P4 P5 P6 P6 P5 P4 P3 P2 P1 P0 P7 P7 P8 P8 P9 P10 P11 P1...

Page 20: ...BS 2A4RTD P1 P1 7 62mm fixed terminal block AC Power 24V OUT AC100 240V IN 250mA max FBS EPW AC DC Power 24V OUT 24VDC IN max 250mA FBS EPW D24 7 62mm fixed terminal block 7 62mm fixed terminal block 7 62mm fixed terminal block 1 7 9 Analog Temperature Combo Module 1 7 10 Expansion Power Module 1 7 11 Voice Output Module 1 7 12 Potential Meter Module 1 7 13 Load Cell Module FBS VOM SDCARD AUDIO OU...

Page 21: ...1 RS232 1 RS485 ports FBs CM25 PORT3 RS232 RX TX T RX N TX PORT4 RS485 G z 1 RS232 1 RS485 Ethernet FBs CM25E PORT3 RS232 RX TX TX TX RX RX RUN LNK PORT4 RS485 T G N ETHERNET 1 2 6 3 z 2 RS485 ports Ethernet FBs CM55E RX TX TX TX RX RX RUN LNK PORT4 RS485 G PORT3 RS485 T N G N T 6 2 1 3 ETHERNET z RS232 RS485 RS222 Converter FBs CM25C RX Converter RS 232 to RS 485 4 TX 422 T RX RX G 2 2 24V FG TX ...

Page 22: ...LER PORT2 PORT1 TX RX RX TX FBs CB55 FBS CB55 z 1 RS232 1 RS485 ports PORT1 RX PORT2 TX PROGRAMMABLE CONTROLLER TX RX FBs CB25 FBS CB25 z 1 Ethernet port LINK CONTROLLER PROGRAMMABLE RX TX ETHERNET FBS CBE z RS485 Repeater FBs CM5R Repeater RX T N TX 24V FG 24V RS 485 T N RX POW G G z GSM GPRS GSM IO3 IO1 IO2 Rx Tx Rx Tx 0 1 0 1 B A B A USB JP1 JP2 I O 24V OFF ON S1 COMMUNICATION GSM MODULE FBS CM...

Page 23: ...ABLE CONTROLLER II0 VI0 VI1 II2 VI3 VI2 FBS B4AD z 2 channel D A analog output board Gnd IO1 CONTROLLER VO1 IO0 VO0 PROGRAMMABLE FBS B2DA z 2 channel A D analog input 1 channel D A analog output board Gnd VI0 VI1 II0 Gnd CONTROLLER IO0 VO0 PROGRAMMABLE II1 FBS B2A1D z Board type FBS BDAP FBS BPEP 1 7 17 Simple HMI z Stand alone OK ESC FBS PEP 1 7 16 Analog Expansion Board ...

Page 24: ...rent top cover as shown in the figure 4 4 80 60 90 PROGRAMMABLE CONTROLLER 2 4 5 90 7 5 2 Outlook II Main Unit FBS 20M FBS 24M FBS 32M FBS 40M FBS 60M Expansion Module FBS 24XY FBS 40XY FBS 60XY FBS 16TC FBS 16RTD 90 W PROGRAMMABLE CONTROLLER 4 4 2 4 5 90 80 7 5 21 W Model 90mm FBS 20M FBS 24M FBS 24XY FBS 16TC FBS 16RTD 130mm FBS 32M FBS 40M FBS 40XY 175mm FBS 60M FBS 60XY units mm units mm ...

Page 25: ... 24YJ FBS 32DGI Modules 1 and 2 have the same type of base with different top cover Top cover of Module 1 is shown in the following figure 2 4 5 90 20 3 8 21 40 80 90 7 5 4 Outlook IV Communication Module FBS CM22 FBS CM55 FBS CM25 FBS CM25E FBS CM55E FBS CM25C FBS CM5R All modules have the same type of base with different top cover Top cover of Module CM25E is shown in the figure 25 90 90 73 25 2...

Page 26: ...H1 23 5 Outlook V Programming Panel FP 08 4 4 53 25 55 5 32 90 188 6 Outlook VI Data Access Panel FB DAP 98 112 148 7 7 14 8 12 17 6 14 75 22 43 9 98 6 5 units mm ...

Page 27: ...4 0 4R DBAN 8 4R DBAN2 3 4R 3 2ψ 8 8 7 5 08 41 27 5 08 5 6 4 3 2 5 08 1 41 91 31 75 5 08 102 86 10 16 41 27 DB 56 8R 3 2ψ 8 5 08 68 9 10 16 158 12 68 9 5 08 48 26 38 1 5 08 5 08 1 2 3 4 5 6 7 8 DB 8 8R 8 7 6 4 5 3 2 1 4ψ 64 48 16 385 28 5 08 5 08 5 08 5 08 8 58 8 58 109 16 81 84 DB2 3 8R ...

Page 28: ...92 4 6 6 78 53 12 98 78 18 3 2 1 364 46 12 98 78 18 12 98 4ψ 64 78 63 6 DB4 0 4R 2 97 33 91 5 08 79 8 6 03 33 90 48 26 38 1 5 08 DBAN 8 4R 37 85 192 02 10 16 37 85 10 16 37 85 5 08 91 44 37 85 10 16 82 80 4 32 DBAN2 3 4R ...

Page 29: ... 14MA MC FBS 20MA MC FBS 24MA MC FBS 32MA MC FBS 40MA MC FBS 60MA MC FBS 20MN FBS 32MN FBS 44MN FBS 24XY FBS 40XY FBS 60XY FBS 8XY FBS 8X FBS 8Y FBS 16XY FBS 16Y FBS 20X FBS 24X FBS 24YT FBS 24YJ Server FBS 6AD FBS 2DA FBS 4DA FBS 4A2D FBS 2A4TC FBS 2A4RTD FBS 2TC FBS 6TC FBS 6RTD FBS 16TC FBS 16RTD FBs 6NTC FBS 7SG1 FBS 7SG2 FBS 32DGI TC AI FBS BDAP FBS BPEP FBS CB2 FBS CB22 FBS CB5 FBS CB55 FBS ...

Page 30: ... slave protocol or any user defined protocol This functionality easily renders the connections with intelligent peripherals such as electronic scale bar code reader and various meters and gauges 2 2 Formation of Multi Unit System By connections through communication ports and specific communication drivers multiple Single Unit PLC systems can be integrated to achieve resources sharing among multip...

Page 31: ...er or other systems with this architecture the FBs PLC is playing the Slave role FBs PLC supports the FATEK and Modbus protocol Connection can be established as long as the upper level computer or intelligent peripherals use either one of the two protocols In the application in which driver for FATEK or Modbus is not available FATEK also provide standard DDE communication server which enables FBs ...

Page 32: ... the ERR LED and put the error code in Y0 Y3 LED refer the page 8 2 Chapter 8 The corresponding error code will also be indicated in the CPU status register R4049 Warning 1 The maximum length of the I O expansion cable for FBS PLC is 5 meters Cables longer than that will cause incorrect I O operation because of excess signal delay in hardware or noise pickup resulting in damage to equipment or pos...

Page 33: ...bers on main units The number of a terminal only represents its order on the expansion unit module For example the first contact is X1 or Y1 the second X2 or Y2 etc All numbers on the expansion unit module begin with 1 The actual number of digital input contact or the output replay however is determined by summing the numbers on all previous expansion units modules and the main unit See the follow...

Page 34: ... user friendly BCD number signal Either the magnitude of voltage or current or the value of BCD number is represented by the 16 bit value of the corresponding register The corresponding current voltage signal or BCD value of any IR or OR on the NI O module is named as a Channel CH The channels on the NI module are called numeric input channels NI channels and those on NO module numeric output chan...

Page 35: ...le starts from the first expansion unit module main unit itself does not have any NI O The first NI channel corresponds to the first IR register R3840 Adding R3840 with the number of IR used by the first NI channel gives the IR number of the second NI channel Adding the IR number of the second NI channel with the number of IR used by the second NI channel gives the IR number of the third NI channe...

Page 36: ...e operation the FBs PLC will read the CH input values from the NI module and stores them into corresponding IR R3804 R3903 and outputs OR values R3904 R3967 to channels on the NO module No pre configuration or setting by users is required 3 2 Expansion of Communication Port The main unit of FBs PLC has one built in communication port port 0 with optional USB or RS232 interface Expansion of communi...

Page 37: ...connector The labels of communication ports are marked on the cover plate of communication boards and modules from which users can easily identify each port Except that the built in communication port Port0 can only be used for USB or RS 232 interface all the other ports Port 1 4 can be used for RS232 or RS 485 interface in CB and CM The following figure shows an example of expansion of 5 maximum ...

Page 38: ...e installed to keep from noise sources such as high voltage or high current lines and high power switches Other precautions are 4 2 1 Placement of PLC Fixation of FBS PLC which can be fixed by DIN RAIL or screws should place vertically and start from the main unit on the left to the expansion unit on the right A typical figure of placement is shown below X3 PORT0 Y3 Suggested arrangement multiple ...

Page 39: ... C6 Y9 Y8 9 7 3 6 5 2 I Y6 FBs 24MCR2 AC FBs 24MCR2 AC Heat ventilation Hanged On floor Vertical with front facing out Horizontal 4 2 2 Ventilation Space The heat in FBS PLC is ventilated via air circulation There should reserve more than 20mm space both below and above PLC and with vertical installation for ventilation as shown in the figure below Distance 50mm 6 2 IN X 2 OUT Y 6 I0 Y3 C4 C6 C2 Y...

Page 40: ...il the upper edge of DIN RAIL groove on PLC back touches the upper tab of DIN RAIL Then use this locked in point as a pivot to press the PLC forward on the bottom and lock it in position The procedure is illustrated below 1 2 Dismount 以 Use a long screwdriver to reach in the hole on the DIN RAIL tab Pull out the tab to pulled out position to remove PLC as shown in the figure below 1 2 Make sure th...

Page 41: ...ns and sizes of screw holes in various models of FBS PLC are illustrated in the following 尺寸 A 60mm 2 362in 90mm 3 543in 21mm 0 827in 4mm 0 157in 2 4 5 mm 0 177 in 尺寸 B 90mm 3 543in 90mm 3 543in 4mm 0 157in 21mm 0 827in 2 4 5 mm 0 177 in 尺寸 C 4mm 0 157in 90mm 3 543in 21mm 0 827in 130mm 5 118in 2 4 5 mm 0 177 in Size A Size B Size C ...

Page 42: ...mm 0 827in 1750mm 6 890in 2 4 5 mm 0 177 in 尺寸 D 尺寸 E 90mm 3 543in 21mm 0 827in 40mm 1 575in 20mm 0 787in 3 8mm 0 150in 2 4 5 mm 0 177 in 尺寸 F 25mm 0 984in 90mm 3 543in 21mm 0 827in 2 4 5 mm 0 177 in 3 8mm 0 150in Size E Size F Size D ...

Page 43: ...wires are preferred It is advised that the length of I O wiring does not exceed 100m 10m for high speed input 4 Input wiring should be separated from output or power wiring at least 30 50mm apart In case separation is not possible adopt vertical crossing no parallel wiring is allow 5 The pitch of FBS PLC terminal block is 7 62mm The torque for screw and suggested terminal is shown below 7 62 mm te...

Page 44: ...pherals 5 1 Specifications and Wiring of AC Power Sourced Power Supply The available AC power supplies of FBS PLC are the 14 Watt SPW14 AC supply for 10 14 PTs main unit the 24 Watt SPW24 AC supply for 20 60PTs main expansion unit and the 14 Watt expansion supply FBS EPW AC for expansion modules Except that the FBS EPW AC is an independent module SPW14 AC and SPW24 AC are to be installed on a main...

Page 45: ...in unit FBS M SW Input CPU 0V 5V 24V 0V AC DC Power Supply F 24V OUT OR 24VDC output for Input Sensor FBS 6AD 2DA 6TC 6RTD 24VDC external power Expansion module Expansion unit Output Output FBS XY AC control Input F 24V 0V 0V 24V 5V control OUT Input AI Expansion power supply FBS EPW AC 5V F 0V 24V 24V 0V OUT control OR IN CONVERTER DC DC AC DC Power Supply AC DC Power Supply 24VDC output for Sens...

Page 46: ...c diagram of DC power supply in main expansion unit is shown below Also be cautious about the following Please follow the wiring schemes regulated by local national standards to choose single pole switch break 24V or double pole switch break both 24V and 24V in order to turn on or off DC input power Wiring of 24V input power must be connected to the terminal labeled by while the 24V end is connect...

Page 47: ...ty Model Output Power 5VDC logic circuit 24VDC output circuit 24VDC input circuit output communication block or expansion cable output expansion cable output terminal block AC P O W E R Main Unit FBS 10 14MA 300mA 340mA FBS 20MA 753 mA 335mA 310mA FBS 24MA 722 mA 325mA 295mA FBS 32MA 712 mA 315mA 262mA FBS 40MA 688 mA 295mA 244mA FBS 60MA 644 mA 255mA 190mA FBS 10 14MC 300 mA 340mA FBS 20MC 753 mA...

Page 48: ...ation will cause a voltage drop by overloading the power supply or intermittent powered with the supply in protection mode either of which will result in unexpected action of PLC and cause harm to people or damage to equipment 5 3 2 Maximum Current Consumption of Expansion Module Without its own power supply expansion modules must be supported by the main expansion unit expansion power or external...

Page 49: ...A FBS CM5H 135 mA Others FBs BDAP 47 mA FBs BPEP 58 mA FBS DAPB 75 mA FBS DAPC 193 mA FP 08 125 mA z The above table lists the required current for the maximum consumption in each expansion module The 24VDC input circuit consumes 4 5mA less per point of OFF state DI in DI O module while the 24VDC output circuit consumes 5mA less per point of OFF state DO The effect of power consumption variation r...

Page 50: ...VDC logic power supply 325 124 136 65 OK External 24VDC Sensor power supply 295 162 53 80 OK Result 1 First calculate current consumption of internal 5VDC logic power supply 722mA 120mA 223mA 119mA 40mA 25mA 195 mA OK 2 And then calculate current consumption of internal 24VDC logic power supply 325mA 124mA 136mA 65 mA OK 3 Calculate current consumption of external 24VDC Sensor power supply 295mA 1...

Page 51: ...K External 24VDC Sensor power supply 295 162 53 80 OK 250 250 OK Result 1 First calculate the current consumption of expansion modules which provided from the main unit current consumption of internal 5VDC logic power supply 722mA 120mA 223mA 119mA 40mA 25mA 195mA OK current consumption of internal 24VDC logic power supply 325mA 124mA 136mA 65 mA OK current consumption of external 24VDC Sensor pow...

Page 52: ...r but different switches or external power supply is used for expansion modules time sequence of both powers should be considered To solve the problem of the expansion unit module power not get ready before main unit power does FBS PLC provides a special R4150 register which can delay the detection time of I O configuration The time base of R4150 is 0 01sec with a default value of 100 namely a 1se...

Page 53: ...current 20mA 10 5mA 7 6mA 4 5 mA Input Status Indication Displayed by LED Lit when ON dark when OFF Isolation Type Photocoupler signal isolation SINK SOURCE Wiring Independent Wiring Via variation of internal common terminal S S and external common wiring List of Input Response Speed for Various Models FBS 20MNR T J X0 1 X4 5 8 9 X2 3 6 7 10 11 1 Limit of input speed in MA model is 10KHz FBS 32MNR...

Page 54: ... SINK or SOURCE input by connecting a 3KΩ 0 5W resistor in series as shown in the figure below A Wiring of 5VDC differential input for Line Driver driving with frequency up to 920KHz for high speed and environments with large noise 雙端輸入 隔離雙絞線 FBS MN主機 Line Driver輸出 B 感應器輸出 A B Wiring of 5VDC differential input to 5VDC single SINK or SOURCE input X1 X1 X0 X0 PNP SENSOR SOURCE輸入 NPN SENSOR SINK 輸入 5...

Page 55: ...ire while the other ends of input circuits are connected to the input terminals X0 X1 X2 etc of PLC Then finish it by connecting the external common wiring and internal common terminal S S to the positive negative terminals of the 24VDC power When connect the internal common terminal S S to 24V positive and the external common wire to 24V negative then the circuit serve as SINK input On the contra...

Page 56: ...ght side of terminal block of FBS PLC there is a place for making SINK or SOURCE label Warning No over current protection is available in the FBS series PLC Except for the 5V differential output circuit all other output circuits have to be added with over current or short circuit protections externally such as fuses in applications with safety concern Terminals labeled by on the terminal block are...

Page 57: ...ection N A Isolation Type Photocoupler Isolation 500VAC 1 minute Electromagnetic Isolation 1500VAC 1 minute SINK SOURCE Output Type Independent Dual Terminals for arbitrary connection Choose SINK SOURCE by models and non exchangeable Bilateral device can be arbitrarily set to SINK SOURCE output List of Input Response Speed for Various Models FBS 20MNR T J Y0 1 Y2 7 Y2 7 FBS 32MNR T J Y0 3 Y4 7 Y8 ...

Page 58: ...the common point Combination of any output common with its individual single end outputs are called a Common Output Block which is available in 2 4 and 8PTs high density module in FBS PLC Each Common Output Block is separated from one another The common terminal has a label initiated with letter C while its numbering is determined by the minimum Yn number which comprise the output block In the exa...

Page 59: ... and Wiring of Single End Transistor SINK and SOURCE Output Circuit A Transistor Single End SINK Output 1A FUSE 2A FUSE 共點輸出區塊 共點輸出區塊 FBS PLC C2 Y2 Y3 C4 Y4 Y5 Y6 Y7 Contact Current A Times of Action ten thousand AC DC power 2PTs Common Output Block 4PTs Common Output Block 4A FUSE 4A FUSE AC DC power ...

Page 60: ...differences in structural and wiring for SINK and SOURCE output circuits respectively 8PTs common has the same block structure and wiring except with different point number The single end SINK output and SOURCE transistor output in FBS PLC are different models The user must check whether it is SINK output model or SOURCE output model when purchasing 2PTs Common Output Block 4PTs Common Output Bloc...

Page 61: ...components The effect of surge currents or counter electromotive force voltages is particularly serious when heavy capacitive or inductive loads are incorporated which may cause damage to the output components or generate noises in other electronic circuits and equipment Among those three FBS PLC output components where TRIAC require no special treatment because of their features of smaller rated ...

Page 62: ...ference The schematic diagrams for AC and DC powers are shown below respectively R C R R 100 120Ω C 0 1 0 24uF PLC Relay output Inductive load Scheme of AC power load R D 1N4001 diode or equivalent device PLC Relay output Inductive load VDC D Suppress by a diode in DC power load for low power R D 1N4001 diode or equivalent device ZD 9V Zener 5W PLC Relay output Inductive load VDC ZD D Suppress by ...

Page 63: ...f high power or frequent ON OFF please construct another suppression circuit to lower noise interference and prevent voltage from exceeding the limit or overheating that may damage the transistor output circuit D 1N4001 diode or equivalent device PLC Relay output Inductive load VDC D Suppress by a diode for low power D 1N4001 diode or equivalent device ZD 9V Zener 5W PLC Relay output Inductive loa...

Page 64: ...mage to the output circuit 8 2 Test Run and Monitoring The FBS PLC provides a convenient feature to Disable Enable the I O points by whole or individually Namely while PLC performs the normal logic scan operation and I O refreshment it does not update the status of the disabled input points according to the actual external input For the disabled output points the result of logic scan can t overrid...

Page 65: ...ds respectively To make PLC enter into Run state or switch from RUN to STOP state it has to be done through the programmer FP 08 or WINPROLADDER Once PLC is set to RUN or STOP it will keep that state even after power off The only exception is when using the ROM PACK no matter if it s running or stopped before power off PLC will automatically enter RUN state with correct ROM PACK syntax check when ...

Page 66: ...replying by looking at the these two indicators The currents in these two LED are constant and their lighting duration is proportional to the reception or transmission time The more received transmitted data or the slower bps reception transmission the longer the reception transmission time and so is the indication time brighter visually If in high speed but small amount of data only short and dim...

Page 67: ...still not functioning well to local distributors 8 5 The Charge of Battery Recycle of Used Battery Every FBs PLC main units have inside one re chargeable lithium battery to safely maintain program and data during main power shut down Each lithium battery was fully charged when the FBs PLC ship out from the factory capable to retain program and data at least 6 months There is risk to miss program a...

Reviews: