Fat Cat GT950 User Manual Download Page 10

Fat Cat

Products Made Exclusively for Aquatic Eco-Systems, Inc. • Phone: 407-886-3939 • Fax: 407-886-6787 • [email protected] • aquaticeco.com

10

General Specifications

12-Month Standard Warranty

Aquatic Eco-Systems, Inc. (AES) products, when properly installed and
operated under normal conditions of use, are warranted by AES to be free
from defects in material and workmanship for a period of 12 months from
the date of invoice from AES, unless otherwise stated. In order to obtain
performance under this warranty, the buyer must promptly give verbal or
written notice of the defect by calling the AES Returns Department at 
407-886-3939, sending a fax to 407-886-6787 or by e-mail to
[email protected]. The buyer is responsible for freight charges, 
both to and from AES, in all cases.

AES warranties do not extend to any goods or parts which have been
subjected to misuse, modification, lack of maintenance, neglect, transit
damage or damage resulting from lightning, natural or accidental flooding,
fire or accident. Operating use or circumstances outside normal conditions,
such as high heat or high moisture, may also be excluded from this warranty.

THIS EXPRESS WARRANTY EXCLUDES ALL OTHER WARRANTIES OR
REPRESENTATIONS EXPRESSED OR IMPLIED BY ANY LITERATURE,
DATA OR PERSON. THE MAXIMUM LIABILITY OF AES UNDER THIS
EXCLUSIVE REMEDY SHALL NEVER EXCEED THE COST OF THE
SUBJECT PRODUCT AND AES RESERVES THE RIGHT, AT ITS SOLE
DISCRETION, TO REFUND THE PURCHASE PRICE IN LIEU OF REPAIR
OR REPLACEMENT.

AES WILL NOT BE RESPONSIBLE OR LIABLE FOR INDIRECT OR
CONSEQUENTIAL DAMAGES OF ANY KIND, however arising, 
including but not limited to those for use of any products, loss of time,
inconvenience, lost profit, labor charges or other incidental or consequential
damages with respect to persons, animals, business or property, whether
as a result of breach of warranty, negligence or otherwise. Notwithstanding
any other provision of this warranty, BUYER'S REMEDY AGAINST AES
FOR GOODS SUPPLIED OR FOR NONDELIVERED GOODS OR FAILURE
TO FURNISH GOODS, WHETHER OR NOT BASED ON NEGLIGENCE,
STRICT LIABILITY OR BREACH OF EXPRESS OR IMPLIED WARRANTY IS
LIMITED SOLELY, AT THE OPTION OF AES, TO REPLACEMENT OF OR
CURE OF SUCH NONCONFORMING OR NONDELIVERED GOODS OR
RETURN OF THE PURCHASE PRICE FOR SUCH GOODS AND, IN NO
EVENT, SHALL EXCEED THE PRICE OR CHARGE FOR SUCH GOODS.
AES EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR USE OR PURPOSE WITH RESPECT
TO THE GOODS SOLD. THERE ARE NO WARRANTIES WHICH EXTEND
BEYOND THE DESCRIPTIONS SET FORTH IN THIS WARRANTY,
notwithstanding any knowledge of AES regarding the use or uses intended
to be made of goods, proposed changes or additions to goods or any
assistance or suggestions that may have been made by AES personnel.

Unauthorized extensions of warranties by the customer shall remain the
customer's responsibility.

CUSTOMER IS RESPONSIBLE FOR DETERMINING THE SUITABILITY 
OF AES PRODUCTS FOR CUSTOMER'S USE OR RESALE OR FOR
INCORPORATING THEM INTO OBJECTS OR APPLICATIONS THAT 
THE CUSTOMER DESIGNS, ASSEMBLES, CONSTRUCTS OR
MANUFACTURES.

This warranty can be modified only by AES personnel by signing a specific,
written description of any modifications

6/17/05 db01

Model

GT950

L x W x H

12.5 x 12.5 x 14 in (32 x 32 x 36 cm)

Weight (Empty)

44 lbs (20 kg)

Engine Type

2-Stroke

Fuel/Oil Mix

Fuel/Oil Mix of 50 to 1

Displacement

63 cc

Operation Time

8 hrs

Noise Level @ 25 ft (7 m)

64 dB

Cooling System

Forced Air

Ignition System

Transistor Control Ignition (T.C.I.)

Fuel Tank

Capacity

1.1 gal (4 liters)

Spark Plug

BPR5ES (NGK)

.028 to .031 in (.7 to .8 mm) Gap

Summary of Contents for GT950

Page 1: ... for Aquatic Eco Systems Inc Phone 407 886 3939 Fax 407 886 6787 aes aquaticeco com aquaticeco com Commercial Duty Power Systems User s Guide Model No GT950 AC PROTECTOR RESET OFF AC OUT ON ENG SW 1 0 STOP Serial Number Date Purchased ...

Page 2: ...n Guidelines 5 Starting the Engine 5 High Altitude Operation 5 Electrical Loads 5 Wattage Reference Chart 6 Stopping the Engine 6 Transport 6 Periodic Maintenance 6 Spark Plug Inspection 6 Air Filter Cleaning 7 Fuel Sediment Cup Cleaning 7 Fuel Tank Filter Cleaning 7 Maintenance Chart 8 Miscellaneous 8 Troubleshooting 9 Generator Won t Start 9 No AC Output 9 Generator Falters Under Load 9 Generato...

Page 3: ...vided in this manual before operating your generator Operator Responsibility Know how to stop the generator quickly in case of an emergency Understand the use of all generator controls output receptacles and connections Ensure that anyone who operates the generator has proper instruction Do not let children operate the generator Carbon Monoxide Hazard Exhaust contains poisonous carbon monoxide a c...

Page 4: ...oil mix Refill the tank outdoors Remove the gas cap slowly to relieve any pressure inside the tank Keep sparks flames heat and other ignition sources away while adding or storing oil and fuel Do not light a cigarette or smoke when refueling Wipe up any fuel spills WARNING Improper connections to a building s electrical system can allow electrical current from the generator to backfeed into utility...

Page 5: ...r cord is in good working order Do not overload the generator The GT950 s specifications are To make sure that your generator can supply enough rated running and surge starting watts for the items you will power at the same time follow these steps 1 Select the items you will power at the same time 2 Add up the rated running watts of these items The generator must produce this total amount of power...

Page 6: ...ch and fuel lever are in the off positions Keep the generator level to prevent fuel spillage Fuel vapor or spillage may ignite WARNING Contact with a hot engine or exhaust system can cause serious burns or fires Let the engine cool before transporting the generator Take care not to drop or strike the generator while transporting Do not place heavy objects on the generator Never operate a damaged o...

Page 7: ...er element and gently squeeze out excess oil Never wring out the filter element as it may tear The generator will smoke if too much oil remains in the filter element 4 Reinstall the filter element and air filter cover Be sure both projections of the air filter cover fit the control box slots before tightening the mount screws Fuel Sediment Cup Cleaning 1 Remove the cup at the bottom of the fuel va...

Page 8: ...Months 50 hrs Six Months 100 hrs Twelve Months 300 hrs Spark Plug Check condition Adjust gap and clean Replace if necessary X Air Filter Clean replace if necessary X Fuel Filter Clean fuel valve and fuel tank filter Replace if necessary X Fuel Line Check fuel hose for cracks or other damage Replace if necessary X Exhaust System Check for leakage Retighten or replace gasket if necessary X Check muf...

Page 9: ...ctrical Loads on page 5 2 A connected device has a short circuit Disconnect the shorted load 3 The generator has a short circuit Contact AES Generator Shuts Down While Running 1 Check the fuel oil mix level and add more if necessary Storage Your generator should be started at least once every seven days and allowed to run at least 30 minutes If you must store the generator for longer periods of ti...

Page 10: ...r charges or other incidental or consequential damages with respect to persons animals business or property whether as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYER S REMEDY AGAINST AES FOR GOODS SUPPLIED OR FOR NONDELIVERED GOODS OR FAILURE TO FURNISH GOODS WHETHER OR NOT BASED ON NEGLIGENCE STRICT LIABILITY OR BREACH OF EXPRESS ...