background image

 

 

CPC514

 

C P C 5 1 4   U s e r   M a n u a l

 

43 

© 2 0 2 0   F a s t w e l     V e r . 0 0 2  

 

ANNEX B: 

DISCLAIMER 

 

This  Disclaimer  contains  special  operating  conditions  of  Fastwel  in  the  following  areas:  intellectual  property,  warranty 
policy, conditions of the order and delivery. 
 

1 INTELLECTUAL PRORETY 

1.1 If any infraction, interference, improper use, illegitimate exploitation and/or violation of the industrial and/or intellectual 
property rights of any third party and/or property, exploitation during the use of Fastwel Embedded Module will take place 
–  Fastwel  does  not  guarantee  to  replace  the materials, computer  programs,  procedures  or  equipment  affected  by  the 
complaint  and  under  no  circumstances  doesn't  bear  responsibility  in  any  form  for  possible  refusal  in  case  of  such  a 
replacement.    
1.2 Use of the Fastwel products as well as the objects of intellectual property containing in them, in the ways and for the 
purposes,  not  provided  by  the  present  user  manual  and  datasheet  isn't  allowed  without  preliminary  written  approval  of 
Fastwel. 
1.3  Fastwel  is  not  responsible  for  possible  incidents  and  losses,  related  to  the  operation  of  end  devices,  in  which  the 
original Fastwel equipment is used.    
 

2 WARRANTY POLICY 

2.1  When  the  detected  flaws  in  an  element  can  be  corrected  without  decreasing  the  foreseen  technical  features  and 
functionality  for it,  User may demand  Fastwel  the  urgent correction  of  the  failures in  additionally  agreed  period  and  an 
increasing of the period of the guarantee of the element equal as the time elapsed from the formal request to repair the 
failures,  until  the  receipt  of  the  repaired  element.  All  costs  associated  to  the  correction  of  failures,  included  those  of 
assembly, dismantle, transport, tests, etc., if they exist, shall be prosecuted according the Warranty Policy of Fastwel.  
 

3 ORDER AND DELIVERY CONDITIONS 

3.1  The  general  rule  is  that  all  Fastwel  equipment  prices  are  determined  with  due  consideration  of  delivery  under  the 
EXW  terms  and  conditions  (Incoterms  2010).  Delivery  of  the  products  under  other  terms  and  conditions  should  be 
preliminary agreed and stated in writing between the parties. 
3.2 Unless otherwise expressly agreed with Fastwel, all the deliveries of Fastwel equipment will be carried out only after 
the official purchase order is obtained and provided that the ordered products have been prepaid in full. Other terms and 
conditions of cooperation should be made in writing. 
3.3  Any  delivery  of  Fastwel  electronics  is  submitted  with  the  right  package  in  accordance  with  the  current  rules  and 
standards in the Member States of the European Economic Area. The purchaser independently bears all risks regarding 
the compliance of package and marking of Fastwel products with legislation requirements being in effect at the place of 
purchased 

products destination (in the buyer’s country). The specified condition excludes unequivocally any liability of 

Fastwel  for  possible  non-compliance  of  package  and  marking  of  products  with  the  requirements  of  legislation  of  the 
country of products destination.  
3.4 In general, all components of the supply are properly protected with respect to freight, in order to avoid any damage 
to the supply, third parties, environmental damages or unrelated goods, as consequence of wrong packaging. 
3.5 Each package unit i

s labeled on the exterior area with the indications of product’s Part Number and Serial Number.  

3.6  The  support  documents  for  the  order  should  be  made  either  in  English  or  in  Russian  unless  otherwise  agreed 
between parties in writing.    
3.7 Fastwel does not pay penalties and does not cover costs associated with delay in the delivery of the products caused 
by  actions  of  the  third  parties,  force-majeure  etc.  -  Fastwel  doesn't  bear  any  responsibility  for  non-execution  or 
inadequate execution of the obligations in a case when it is caused by actions of the third parties (for example producers 
or suppliers of accessories), force majeure etc. 
3.8 Fastwel declares that independently and at any time without damage, it has an exclusive right to define and change 
functionality architecture, bill of materials of its products without any preliminary coordination and approvals of the third 
parties. 
 

4 OTHER CONDITIONS 

4.1  Fastwel  has  the  obligation  to  respect  the  current  Russian  legislation  (including,  but  not  limited  to  environmental, 
labor, social laws) in each moment and to apply it to its embedded electronics considering all and each execution phase, 
that is to say, from the design until the commissioning and subsequent maintenance.  In this regard Fastwel is not liable 
to  the user  or  other  persons in  connection  with  possible changes  of  the company’s  rules  (including, but  not  limited to 
warranty, ordering policy) caused by changes of the Russian legislation. 
4.2 Unless otherwise expressly agreed in writing, Fastwel provides no training for 
assembly\installation\adjustment\operation of its equipment.

 

Summary of Contents for CPC514

Page 1: ...CPC514 3U CPCI Serial Elbrus CPU Module User Manual Rev 002 November 2020 The product described in this manual is compliant with all related CE standards ...

Page 2: ...te 001 Preliminary version CPC514 February 2019 002 Compliance assessment CPC514 November 2020 Contact Information Fastwel Co Ltd Fastwel Corporation US Address 108 Profsoyuznaya St Moscow 117437 Russian Federation 6108 Avenida Encinas Suite B Carlsbad CA92011 USA Tel 7 495 232 1681 Tel 1 858 488 3663 Fax 7 495 232 1654 E mail info fastwel com E mail info fastwel com Web http www fastwel com ...

Page 3: ...ram 21 2 2 Specific features of the functional nodes operation 22 2 3 Module s interfaces 23 2 4 LEDs 27 2 5 Configuration switches 28 2 6 Power supply interaction 28 3 Installation 32 3 1 Safety requirements 32 3 2 Module installation procedure 33 3 3 Procedure for module s removal 34 4 Setting Operation Modes 36 4 1 Reset the loader to default settings enable Transparent mode loader microchip pr...

Page 4: ...ing and debugging control microcontroller 26 Table 2 4 Assignment of microchip programming connector with the XP3 bootloader code 26 Table 2 5 Assignment of pins of the JTAG connector for XS6 processor debugging 26 Table 2 6 Assignment of COM1 connector contacts and DisplayPort XP1 settings 27 Table 2 7 Designations and functions of the LEDS in CPC514 CPC514RC 27 Table 2 8 Assignment of configurat...

Page 5: ...hat it describes However Fastwel accepts no responsibility for inaccuracies omissions or their consequences as well as liability arising from the use or application of any product or example described in this document Fastwel Co Ltd reserves the right to change modify and improve this document or the products described in it at Fastwel s discretion without further notice Software described in this...

Page 6: ...nsequences as well as liability arising from the use or application of any diagram product or example given in this document Fastwel Group reserves the right to change and improve both this document and the product presented inside of it at its discretion without any further notice Safety requirements This Fastwel Group s product is developed and tested for the purpose of ensuring compliance to th...

Page 7: ...ng with high voltage Attention Static sensitive device This sign and text indicate that electronic boards and their components are sensitive to static electricity so care should be taken when handling this device and performing inspections to ensure integrity and functionality of the device Attention Hot surface This sign and text warn of the danger associated with touching hot surfaces of the dev...

Page 8: ... the device so always unplug the power supply cord while carrying out of works The same also applies to the other power supply cables Instructions for board handling Static sensitive device Electronic boards and their components are sensitive to static electricity Therefore special attention should be given when handling these devices to ensure their safety and operability Do not leave the board i...

Page 9: ...ANTIES Warranty liabilities The manufacturer guarantees that the CPC514 meets the requirements of technical specifications of the MODULES IN 3U COMPACT PCI FORMAT IMES 469555 001 TU the CPC514RC module meets the requirements of technical specifications of the RC MODULES IN 3U COMPACT PCI FORMAT IMES 469555 002 TU provided that the Consumer complies with the operating conditions transportation stor...

Page 10: ... change of a polarity sign to the opposite one of the power supply source incorrect operation transportation storage installation mounting or accident Procedure for returning products for repairs Sequence of actions when returning products for repairs contact the product Supplier for return material authorization for the product attach to the returned product the fault identification report made i...

Page 11: ...s currently valid for this type of transport During handling operations and transportation the packed modules should not be subjected to sudden shocks drops impacts and precipitation The packed modules should be placed on the vehicle in such a way as to preclude their further movements Unpacking Before unpacking after transportation at negative ambient temperatures the modules must be kept for 6 h...

Page 12: ...hs since the date of purchase For customized products the warranty period is 60 months from the date of sale unless otherwise provided by the delivery agreement The warranty set forth above does not extend to and shall not apply to 1 Products including software which have been repaired or altered by other than Fastwel personnel unless Buyer has properly altered or repaired the products in accordan...

Page 13: ...special purpose systems for working under harsh operating conditions This User Manual covers the both module versions 1 1 General features Elbrus 4S CPU 1891VM8YA VLIW processor of Elbrus architecture 600 MHz 4 processor cores L1 cache of data for a core 64 KB L1 cache of commands for a core 128 KB L2 cache 8 MB RAM DDR3 SDRAM 800 MHz with ЕСС support 8 GB soldered 2 channel Flash BIOS 64 Mb SPI F...

Page 14: ...d start diagnostics LED Hot Swap indicator NT PCI Express port status LED LED for addressing to SATA drives LED for module s temperature mode indication Two program controlled LEDs user LEDs Power supply and current consumption 5 V 5 no more than 0 5 A 12 V 5 no more than 3 A Humidity Up to 80 non condensing Up to 98 non condensing for the Coated option Resistance to mechanical stress Sinusoidal v...

Page 15: ...n Table 1 1 Table 1 1 Version of the CPC514 module Name Conventional designation Ordering name Note CPC514 CPU Module CPC514 CPC514 01 The CPCI Serial 3U 4HP Module with 4 core CPU 600 MHz 8GB RAM with convection cooling designed for operation within the temperature range from 40 to 70 ºC CPC514RC 01 The CPCI Serial 3U 5HP Module with 4 core CPU 600 MHz 8GB RAM with conduction cooling designed for...

Page 16: ...aging information Packaged module weight in kg no more than CPC514 0 75 CPC514RC 0 83 Note Keep the original antistatic packaging and consumer packaging of the module until the end of the warranty period 1 6 Location of elements The figures below show the external view of the CPC514 CPC514RC modules their overall dimensions and the location of elements 1 6 1 External view of the module Fig 1 1 Ext...

Page 17: ...14 C P C 5 1 4 U s e r M a n u a l 15 2 0 2 0 F a s t w e l V e r 0 0 2 Fig 1 2 External view of CPC514RC Note The external view of the module versions may slightly differ from the one shown in the figures ...

Page 18: ...PC514 C P C 5 1 4 U s e r M a n u a l 16 2 0 2 0 F a s t w e l V e r 0 0 2 1 6 2 Overall dimensions mounting dimensions and location of the main components Fig 1 3 Overall dimensions of the CPC514 module ...

Page 19: ...CPC514 C P C 5 1 4 U s e r M a n u a l 17 2 0 2 0 F a s t w e l V e r 0 0 2 Fig 1 4 Overall dimensions of the CPC514RC module ...

Page 20: ...M a n u a l 18 2 0 2 0 F a s t w e l V e r 0 0 2 Fig 1 5 Location of the main components of the CPC514 CPC514RC elements block top view Fig 1 6 The location of the main components of the CPC514 CPC514RC elements block bottom view ...

Page 21: ...r button shown as button A performs a mechanical function it is used for installing removing the CPC514 module see subparagraph 3 2 Installation Procedure and 3 3 Module Removal Procedure You can also use the extractor button to manually activate and deactivate module Fig 1 7 Front panel of the CPC514 Module Top fixing screw Button A programmable Bottom fixing screw ...

Page 22: ...dles fulfill a mechanical function they are used for installing removing the CPC514RC module Fig 1 8 Front panel of the CPC514RC Module Top screw of the wedging mechanism Handle of the A extractor Opening for a fixing screw of the front panel Opening for a fixing screw of the front panel Handle of the B extractor Bottom screw of the wedging mechanism ...

Page 23: ...CPC514 C P C 5 1 4 U s e r M a n u a l 21 2 0 2 0 F a s t w e l V e r 0 0 2 2 Functional description 2 1 Block diagram Fig 2 1 Block diagram of the CPC514 CPC514RC module ...

Page 24: ...ontrollers The module has 2 built in Gigabit Ethernet interfaces Two ports are routed to the front panel connectors The interfaces are implemented on Intel high speed server controller Marvell 88E1111 Ethernet Controller In addition the module has a Gigabit Ethernet interface implemented on the Controller of peripheral interfaces PHY Marvell 88E1111 bundle The interface is routed to the J6 CPCI Se...

Page 25: ... is on From the Reset button of the Utility backplane connector From the button in the handle extractor of the CPU module only for CPC514 Switches Jumpers The module is equipped with switches for the following functionalities NVRAM reset Reset of BOOT Setup Protection against overwriting BOOT Enabling the Peripheral Root mode Process switches LEDs The LEDs indicating start diagnostics activity of ...

Page 26: ... in Table 2 2 Table 2 2 Assignment of the XS4 connector pins for installing the mezzanine module 2 3 3 USB DisplayPort and Ethernet Interfaces The assignment of the USB DisplayPort and Ethernet interface pins on the front panel and backplane connectors complies with the description given in the specifications for the corresponding interfaces and the CPCI Serial standard Figure 2 2 shows the number...

Page 27: ...CPC514 C P C 5 1 4 U s e r M a n u a l 25 2 0 2 0 F a s t w e l V e r 0 0 2 Figure 2 2 Numbering of interfaces supported by the CPC514 CPC514RC module in the Compact PCI Serial backplane ...

Page 28: ...eception channel of the MK serial port TTL level 5 3V3 3 3 V 6 GND Ground Table 2 4 Assignment of microchip programming connector with the XP3 bootloader code Pin number Signal Name 1 VCC Power supply voltage for programming 3 3V 2 GND Ground 3 CS Microchip selection 4 SCK Clocking 5 SO Data output 6 SI Data input 7 OE Switching the microchip pinouts to the connector you should set 1 for programmi...

Page 29: ... indicators which are described in Table 2 7 Table 2 7 Designations and functions of the LEDS in CPC514 CPC514RC LED designation Description SYS Two color red and blue Blue Not illuminated normal operation flashing waiting for the OS to complete operation when hardware shutdown is performed using the extractor button Is ON constantly the supply is off Red hardware failure power supplies startup er...

Page 30: ...it that enables power supply in two modes with support for power supply control similar to the control that is used in ATX power supplies and without control support When the CPC514 CPC514RC module is running each of the above modes can be used in the system slot of the Compact PCI Serial backplane The power supply control is supported by the CPC514 CPC514RC module only when installed in the syste...

Page 31: ...he module starts automatically if there is 12 V If one of the power sources both external and internal fails the red SYS LED is illuminated The main power supply from the CPU module is turned off and only the LED display system works Complete shutdown of the system CPU module and peripheral modules is only possible for the power supply with management support If the power supply unit does not supp...

Page 32: ...using software via ACPI After executing any of the shutdown algorithms the system or only the CPC514 CPU Module enters the Software shutdown state From this state switching to the complete disabled state Mechanical shutdown or to a completely enabled state is possible Switching to the enabled state is performed by pressing the extractor s handle button or the Power Button ...

Page 33: ...CPC514 C P C 5 1 4 U s e r M a n u a l 31 2 0 2 0 F a s t w e l V e r 0 0 2 Fig 2 5 Algorithm for enabling the system from the software shutdown state ...

Page 34: ...should not be placed in any container until the heatsink has cooled down to the room temperature Attention Turn off the system power before installing the module in an empty slot Violation of this rule may pose a threat to your health and life as well lead to the damages to the system or module If you need to place the module on the table make sure that the module is facing down Static sensitive d...

Page 35: ...hes the backplane connector Using the handle on the front panel push the module into the backplane connector Do not put too much effort when you insert the module connector into the backplane connector Finish the module s installation by lowering the handle down hooking it to the frame of the system enclosure and snapping the connection see Fig 3 1 Make sure that the module is flush mounted with o...

Page 36: ...fety requirements listed in Chapter 3 1 Special attention should be given to the warning concerning the heatsink temperature Prior to start the work make sure that the system is powered off In order to remove the module follow the steps in the below sections 3 3 1 Removal of CPC514 In order to remove the CPC514 module follow the below steps Disconnect all interface cables from the module Unscrew t...

Page 37: ...CPC514 C P C 5 1 4 U s e r M a n u a l 35 2 0 2 0 F a s t w e l V e r 0 0 2 After the module is removed from the backplane connector pull it out of the slot Removal of the module is completed ...

Page 38: ...ction against rewriting For a prompt reset of loader settings to default parameters and protection of the loader memory chip against program rewriting from the OS SA2 switch is used In order to switch the module to the Peripheral Root mode only when the CPC514 CPC514RC module is installed into peripheral slot the SA1 switch is used Fig 4 1 Switch SA1 in CPC514 Fig 4 2 Switch SA2 in CPC514 ...

Page 39: ...t of loader settings to standard values ON Clearing the NVRAM memory by reboot OFF Normal position memory is not cleared 2 Protection against rewriting the loader s memory chip ON Protection against rewriting the chip with the bootloader code is enabled OFF Rewriting protection is disabled 4 2 Loader settings reset sequence Sequence of loader settings reset Switch off the power Remove the CPC514 C...

Page 40: ...e operating system will be loaded enter the following commands 1 Enter d to view the available disks and partitions 2 Enter u to view the current boot disk and partition 3 If the current section needs to be changed enter c After that upon request you should enter the disk number and partition number You can skip command line parameters and names of the boot files by pressing Enter The Autoboot in ...

Page 41: ...y designed copper heatsink is used to maintain the temperature of the processor chip within the acceptable values Elbrus 4C processors do not have dynamic thermal control so the value of the module s heat output remains to be constant maximum regardless of the processor core load The cooling radiator is designed to use the module at ambient temperatures of no more than 70 C and with an air flow ra...

Page 42: ... voltage V Minimum voltage V Maximum voltage V Average current consumption A 5V Standby 4 75 5 25 0 5 12 10 8 13 2 3 5 The CPC514 CPC514RC module for its operation uses two voltages 12 V and 5 V Standby The 5 V Standby voltage is optional While using it you can control the power supply source using the PS_ON signal in the Utility connector of the backplane If the supply voltage exceeds the specifi...

Page 43: ...on g 2 Sinusoidal vibration for CPC514RC Range Hz 10 500 Acceleration g 6 Single action mechanical shock for CPC514 Peak acceleration g 50 Duration ms 11 Single action mechanical shock for CPC514RC Peak acceleration g 75 Duration ms 1 5 Repeated mechanical shock for CPC514 Peak acceleration g 25 Duration ms 6 Repeated mechanical shock for CPC514RC Peak acceleration g 15 Duration ms 5 15 Damp heat ...

Page 44: ...rnet Gigabit Ethernet I2C Inter Integrated Circuit PC Personal Computer PCI Express PCIe or PCI E PCI Express Peripheral Component Interconnect Express officially abbreviated as PCIe or PCI E Represents a high speed serial computer expansion bus standard designed to replace the older PCI PCI X and AGP bus standards MTBF Mean time before failure SATA Serial ATA SMBus System Management Bus USB Unive...

Page 45: ...full Other terms and conditions of cooperation should be made in writing 3 3 Any delivery of Fastwel electronics is submitted with the right package in accordance with the current rules and standards in the Member States of the European Economic Area The purchaser independently bears all risks regarding the compliance of package and marking of Fastwel products with legislation requirements being i...

Reviews: