Editie 2.3 pg7
This is used to determine which of the recipients you just created in the Phone directory must be
called when a button is pressed.
This page is licence‐related: only 1 button is visible here because a door intercom with 1 button was
purchased.
User name:
choose the recipient who is to be called first here. This must be created under Phone
Directory. Up to 10 numbers are possible.
When a recipient does not answer the call, the next recipient will be called.
When a call is launched outside the time profile that is linked to a recipient, the next recipient that
does fall within the time profile is chosen automatically.
The number of buttons that appears depends on the licence that was purchased.
3.7 Timing Settings
Forward time out:
indicates the time when a subsequent recipient is called after the previous one
does not answer the call.
Max Call duration:
Enter here in seconds the maximum duration of a conversation.
DTMF hangup:
this code will force the call to end.
3.8 Time profiles
A time profile can be created here that can be linked to a recipient under Phone Directory.
Recipients are only called when the call falls within the time profile. If no time profile is linked to a
recipient, the call will always be launched.
Two time profiles have already been pre‐programmed: 4/5 and full time (full work week).
3.9 Device settings
The Wizard Classic IP is equipped with 1 RGB LED that illuminates the push button. Here you can set
the color of that LED.
Editie 2.3 pg8
Choose the different grayscale for less bright white light.
Auto reboot
: You can have the device reboot automatically at three different times.
3.10 Relay settings
Internal relays:
The two internal relays of the Wizard IP are configured here.
They can be disabled and the time duration in milliseconds can be adjusted.
This means that a duty cycle of 2000 equals a 2‐second pulse.
DTMF: This is the code that must be entered to open the relay with the telephone.
You can control both relays not only via DTMF but also with a URL command. This is useful when, for
example, you use the Fasttel indoor station VISITOR! You can then open the gate from the main
screen without being connected to the Wizard. You create in the VISITOR! an html activation with the
username and password you entered above. The correct https link will be displayed here
immediately.
External relays: