Bail Handle Compressed Gas Connectors
FasTest, Inc. 1646 Terrace Drive Roseville, MN 55113 Support: (800) 444-2373 Fax: (651) 645-7390 www.fastestinc.com
11
problem
recognized By
probable cause
recommended action
Connector’s thread
collets not expanding
properly during initial
hook-up to cylinder valve
Visual inspection of
connection joint
Short connection of connector
to valve
Visual inspection of valve.
Replace if damaged or worn.
Disconnect and reconnect
connector to valve. Be sure
actuator handle sleeve is fully
engaged. If problem is unresolved,
contact
FasTest
Loose connection
Connector is loose
despite proper
connection
Worn or damaged threads of
cylinder valve
Replace cylinder valve.
Damage, deformation
or distortion to connector
body, sleeve, and collet
threads. Possible internal
leakage
Visual inspection of
connector
Difficult operation of
connector
Improper operation
Remove connector from filling
operation immediately!
Return to
FasTest
to determine
probable cause
Inability to connect to,
or a leakage with 540
and 580 RPV style
connectors and Residual
Pressure Valves
Inability to fully
actuate connector
actuator handle and/
or outer sleeve
(a) Bent actuator pin
(b) Damaged actuator piston
(a) Replace actuator pin
(b) Return to
FasTest
for repair
Inability to connect or
leakage of RPV version
connector to non RPV
cylinder valves
Inability to fully
actuate and/or gas
leakage at initial filling
(c) Actuator pin not retracted
(c) Retract/remove actuator pin
according to specific connector
operation instructions
trouBlesHootIng