PAGE 11
If using ACE PWM pump, change the coil frequency to 122.
Max Pump PWM:
Enter a maximum PWM duty cycle percent to set the maximum desired output for a
pulse width modulated (PWM) hydraulic control valve. This setting limits how far the
PWM valve will open.
(Typically set at 100 psi. deadhead.)
Min Pump PWM:
Enter a minimum PWM duty cycle percent to set the minimum desired output (zero point
or shutoff point) for a pulse width modulated (PWM) hydraulic control valve).
(Typically set at 20 psi. deadhead.)
PWM Standby:
Enter desired control valve PWM duty cycle percent when all sections are off. This is uti
-
lized when standby pressure control is not available (pressure sensor not available or
direct injection is installed).
(Typically set at within 10 psi of spray pressure.)
Press Next.