Start up the dispenser software (e.g. PrismaPro). This should initialise the dispenser, and turn table
should turn one or two times
9.
After the initialization, the dispenser will automatically start agitation. If not, start agitation from the
dispenser software
10.
While dispenser is agitating, open the canister lid one by one and check if the stirrer blades are
turning.
a.
If none of the stirrer is turning, the agitation did not start successfully. You may need to
consult with your service contact.
b.
If some stirrers are turning but others are not, you may need to replace the stirrer pin or take
other actions. You may need to consult with your service contact.
11.
From the dispenser software, go to the
“F
ill canister
/ Refill”
option, and check each canister to
ensure sufficient amount of colorant is in the canister, and that the software reflects the correct
amount.
12.
Go to the
“M
anual Dispense
”
option of a dispenser software, and dispense about 1ml from each
pump. Starting with small amount dispense may be helpful after a long period of non-usage.
13.
If you manually cleaned the nozzles in step 4, conduct larger dispense (around 10ml), to eliminate air
in the nozzle area.
14.
Pay a good attention during the dispensing process, and if error occurs, you may need to consult with
your service contact. Also observe the pump nozzle area during the dispenses:
a.
To see if colorant is dispensed in an angle. If so, clean the nozzle area with a wet cloth / wet
wipe etc to remove dried colorants. Test again and ensure that the colorant is dispensed
straight down
b.
To see if colorant drops when the nozzle is opening or closing (as opposed to when the pump
is pushing the colorant out of nozzle). If so, it is possible that there is unwanted air in the
system. You may be able to eliminate the air by conducting large dispenser (approx. 200ml).
Test again and ensure no unwanted drop occurs during valve opening / closing
15.
Go to the “Maintenance” option, and conduct “Purge” from each pump. Pay a good attention during
this process, and if any error occurs, you may need to consult with your service contact
16.
Check again if the brush is clean, and that there is correct amount of cleaning liquid (water / solvent)
in the brush container
17.
Conduct a formula dispense as a test. Check if all peripherals are working (e.g. label printer,
spectrophotometer). If any issues, consult with your product supplier / service contact