Start up the dispenser software (e.g. PrismaPro). This should initialise the dispenser, and turn table 
should turn one or two times 

9.

 

After the initialization, the dispenser will automatically start agitation. If not, start agitation from the 
dispenser software 

10.

 

While dispenser is agitating, open the canister lid one by one and check if the stirrer blades are 
turning.  

a.

 

If none of the stirrer is turning, the agitation did not start successfully. You may need to 
consult with your service contact. 

b.

 

If some stirrers are turning but others are not, you may need to replace the stirrer pin or take 
other actions. You may need to consult with your service contact.  

11.

 

From the dispenser software, go to the 

“F

ill canister 

/ Refill”

 option, and check each canister to 

ensure sufficient amount of colorant is in the canister, and that the software reflects the correct 
amount. 

12.

 

Go to the 

“M

anual Dispense

 option of a dispenser software, and dispense about 1ml from each 

pump. Starting with small amount dispense may be helpful after a long period of non-usage.  

13.

 

If you manually cleaned the nozzles in step 4, conduct larger dispense (around 10ml), to eliminate air 
in the nozzle area. 

14.

 

Pay a good attention during the dispensing process, and if error occurs, you may need to consult with 
your service contact. Also observe the pump nozzle area during the dispenses: 

a.

 

To see if colorant is dispensed in an angle. If so, clean the nozzle area with a wet cloth / wet 
wipe etc to remove dried colorants. Test again and ensure that the colorant is dispensed 
straight down 

b.

 

To see if colorant drops when the nozzle is opening or closing (as opposed to when the pump 
is pushing the colorant out of nozzle). If so, it is possible that there is unwanted air in the 
system. You may be able to eliminate the air by conducting large dispenser (approx. 200ml). 
Test again and ensure no unwanted drop occurs during valve opening / closing 

15.

 

Go to the “Maintenance” option, and conduct “Purge” from each pump. Pay a good attention during 

this process, and if any error occurs, you may need to consult with your service contact   

16.

 

Check again if the brush is clean, and that there is correct amount of cleaning liquid (water / solvent) 
in the brush container 

17.

 

Conduct a formula dispense as a test. Check if all peripherals are working (e.g. label printer, 
spectrophotometer). If any issues, consult with your product supplier / service contact 

 