3-6

6

Calibration SME

Switch on the wheel balancer.

MAIN MENU > MENU > RESET

 > 

CALIB

 > 

SME

CALIBRATION

 > 

SET/OK 

Put the rod on rest position (fig. 53) and press 

SET/ OK.

Put the rod (fig. 54) and press 

SET/OK.

Press 

<ESC>

 to go back to standard use

.

Fig. 53

Fig. 54

Summary of Contents for VIDEOTRONIC V688.G3

Page 1: ...V688 G3 User s Manual 15 July 2019 For any information please contact www fasep it e mail export fasep it FASEP 2000 srl Via Faentina 96 50032 Ronta Fi Italy Tel 39 055 840 3126 Fax 39 055 2691906 i...

Page 2: ...ence breakdown accidents due to unauthorized modifications of the unit use of non original or unauthorized accessories see Accessories listing in this manual for a list of original accessories availab...

Page 3: ...ancer and position weight 2 6 5 Calibration ALU SE 3 5 6 Calibration SME 3 6 7 MEASUREMENT AND CORRECTION OF UMBALANCE 3 7 7 1 Placing the wheel rim on the wheel balancer 3 7 7 2 Input of Rim Dimensio...

Page 4: ...parately This unit is designed for indoor use only see Environmental Data appendix for reference CAUTION This unit is designed to spin vehicle wheels only within the range of dimensions and weight app...

Page 5: ...provided with a ground terminal 2 4 5 Make sure that Power Rate Specifications for your wheel balancer refer to nameplate on the wheel balancer comply with those provided by the external power source...

Page 6: ...uly 2019 2 2 3 USE OF CONTROL PANEL 3 1 Meaning of the icons on the screen Select balancing mode APS Function Calibration Delete last character in input activation code Change selection Set default va...

Page 7: ...revious page Fine resolution Access to Information center Access to page measures Laser calibration Put in the rod laser in rest position Start laser Extract fully rod laser Manul input measures Set D...

Page 8: ...are Reset partial statistics Reset variation in page Sensor Save Set measures Go to setup men Skip current operation Split function Stop turning wheel Key up View men and selection UP DOWN Automatic f...

Page 9: ...s c indicated point of unbalance constantly wrong d more than 2 spins required to balance wheels repeatedly Switch on the wheel balancer Select SET UP CALIBRATION SET OK CALIBRATION SET OK Spin with n...

Page 10: ...t a wheel on the shaft and press START Fig 47 Put the calibration weight Fig 48 and press SET OK Close the wheel guard or press START At the end of the spin 160 0 will show on the video tolerance allo...

Page 11: ...el balancer MAIN MENU MENU RESET CALIB ALU SE CALIBRATION SET OK Put the rod on rest position fig 50 and press SET OK Put the rod on the flange fig 51 and press SET OK Select width of wheel Put the ro...

Page 12: ...l 15 July 2019 3 6 6 Calibration SME Switch on the wheel balancer MAIN MENU MENU RESET CALIB SME CALIBRATION SET OK Put the rod on rest position fig 53 and press SET OK Put the rod fig 54 and press SE...

Page 13: ...es is of basic importance for correct balancing Good results depend on proper performance of these procedures To accurately clean up the superficial ones of connection before whichever operation CAUTI...

Page 14: ...tance IN2 Press ALU MODE untill the required position of weight is on the video fig 59 Insert the distance IN1 Insert the distance IN2 7 4 Detecting and correcting umbalance 7 4 1 After setting wheel...

Page 15: ...ight using LASER Turn the wheel until the position weight indicators of one side are both green fig 65 The laser come out to show the point of application of the weight fig 66 Apply the weight on the...

Page 16: ...rim and put the wheel on the shaft fig 68 Spin the wheel Select the optimization and follow the video instruction WARNING Balancing with flanges put the accessories assembled to the rim during the co...

Page 17: ...er s Manual 15 July 2019 5 1 9 SPECIAL FUNCTIONS 9 1 Language selection 9 1 1 MAIN MENU SET UP USER SET UP LANGUAGE SET OK 9 1 2 Select the language and press SET OK 9 2 Setup 9 2 1 MAIN MENU SET UP U...

Page 18: ...easures APPENDIX A Technical data Power requirement 400W Speed Balancing 98RPM Measuring time 4 15 s Accuracy 1grammo 1 28 once Wheel Dimensions Diameter Rim diameter 8 200 mm 26 650 mm Rim Width with...

Page 19: ...directly by unauthorized service Service to any parts by unauthorized engineers will void warranty and will any right of the owner of the unit NOTE As this unit runs at speed below 100rpm a safety cov...

Page 20: ...ver is open ERR 7 Measuring cycle was interrupted ERR 8 Calibration weight was not inserted ERR 9 Activation code not correct ERR 10 Overflow in calculations ERR 11 Serial number is wrong ERR 12 Seria...

Page 21: ...se be caused by inappropriate waste handling of the battery The recycling of the materials will help to conserve natural resources In case of products that for safety performance or data integrity rea...

Reviews: