Videotronic V548.G4.U: User’s Manual
11 March 2022
11
5
Calibration ALU-SE
Switch on the wheel balancer.
MAIN MENU > MENU > RESET
>
CALIB
>
ALU-SE
CALIBRATION
>
SET/OK
(fig..49).
Put the rod on rest position (fig.49) and press
SET/ OK.
Put the rod on the flange (fig.50) and press
SET/ OK.
Select width of wheel
Put the rod on internal side of the rim (fig.51) and press
SET/OK.
Press
<ESC>
to go back to standard use
.
Fig. 50
Fig. 51
Fig. 52