![Fasep B202 User Manual Download Page 23](http://html1.mh-extra.com/html/fasep/b202/b202_user-manual_3523518023.webp)
Fasep 2000 srl
Rev. 1.1
Balatron 202: User’s Manual
June,1 2013
4-i
F
IG
.
7
F
IG
.
8
F
IG
.
9
F
IG
.
10
4
CALIBRATION
4.1
How to calibrate the Wheel Balancer (USER)
NOTE
the following symptoms indicate need for calibration:
a) check calibration program fails.
b) constant low or high weight readings.
c) indicated point of unbalance constantly wrong
d) more than 2 spins required to balance wheels repeatedly
Switch on the wheel balancer.
Press
<SET>
when
SOF
X.XX
(software version) is
displayed. It will appear
CAL
on the left display.
Press
<SET>
to start the calibration program.
Insert the distance measurement (IN) (Fig. 8).
Insert the diameter measurement (DIA).
Spin the wheel using the wheel spinner (Fig. 9).
NOTE:
ACC EL:
impress greater speed.
RED UCE:
reduce the speed.
GO OD:
the speed is corrected.
Turn the wheel until the writing
60 PUT
is displayed.
Apply a 60g adhesive weight on the internal side of the
wheel (Fig.11).
Press
<SET>
; while the wheel is maintained in the
point of the application of the weight, on the display of
left appears
C2.
Spin the wheel using the wheel spinner.
End of calibration
.
Press
<MODE/ESC>
to return to normal balancing
mode.
NOTE
technical calibration is only available for qualified personnel.