![Fasel Elektronik FCU6x00 Series Installation And Operating Manual Download Page 22](http://html1.mh-extra.com/html/fasel-elektronik/fcu6x00-series/fcu6x00-series_installation-and-operating-manual_3542243022.webp)
Operation
22
Installation and Operating Manual / Version V 1.02
A bath mode is selected and active (orange)
1.
Press the key for the active bath mode. This stops the bath mode. The key is now
blue.
2.
Use the "Control unit standby" or "Power Off" key to switch off the sauna control
unit
See page 18.
6.3
Setting bath mode
The control unit is switched on.
1. Select the preferred bath mode on the display (see Table 2).
2. Use the adjustable slider in the "Temperature / Humidity setting" section to set the
preferred temperature / humidity (see Table 4).
3. The current values in the cabin for temperature/humidity are shown in the section
"Display temperature/humidity. The values are also shown as icons in the display.
4. To adjust the heating period, press and hold the section "Heating period / Remain-
ing heating period" until the menu opens.
NOTE!
The program automatically skips to the home page if there has been no
key operation for several seconds. (It skips to the timer menu if the control
unit has an active timer).
Bath mode
Slider symbol
Meaning
Bath mode Sauna
Set the target temperature in the sauna.
Bath mode Sauna with humidity (only FCUX200 and FCUX400)
Set the target temperature in the sauna.
Set the target humidity in the sauna.
Bath mode Infrared (only FCUX400)
Set the base temperature in the sauna.
Set the maximum temperature in the sauna cabin
using the infrared heater
Bath mode Steam bath (only FCUX000-STEAM)
Set the temperature in the steam bath.
Table 4: Temperature / Humidity setting
Summary of Contents for FCU6x00 Series
Page 2: ......
Page 34: ......
Page 35: ......
Page 36: ...Address of the installer or the dealer of the sauna sys tem...