![Fasel Elektronik FCU3000 Series Installation And Operating Manual Download Page 27](http://html1.mh-extra.com/html/fasel-elektronik/fcu3000-series/fcu3000-series_installation-and-operating-manual_545981027.webp)
Faults
Installation and Operating Manual / Version V 1.02
27
8.2
Messages and instructions on the display
Messages and instructions may be shown on the display that require the operator to
take action.
Messag-
es/Instruction
s
Possible causes
Measures
To be carried
out by
Device not re-
sponding
Sauna control unit is
switched off.
Switch on the sauna control unit.
Operator
Connection to
the server
failed
1. No server connection
with the App.
2. No server connection of
the Connect Box.
1. Check the Internet connection on
your Smartphone/Tablet
2. Restart the Connect Box and wait for
about 5 minutes until the connection to
the server is established.
Pay attention to the beep confirmation.
Operator
USB
NOT EXISTS
USB connection interrupted Check if the USB cable between FCU
and Connect Box is plugged in.
Restart the Connect Box and wait for
about 5 minutes until the connection to
the server is established.
Pay attention to the beep confirmation.
Operator
Water
deficiency
Evaporator without water
Fill water according to the operating
manual of the evaporator.
Operator
Check water inlet / magnetic valve on
the evaporator.
Specialist/
electrician
Drying function
interrupted
After completion of the
“Sauna with humidity” bath
mode, the cabin is auto-
matically dried for a defined
period and at a defined
temperature. This drying
function helps to avoid
damage to the cabin, e.g.
mould growth. This drying
function was interrupted
prematurely.
Follow the instructions on the display:
Restart the drying function
Cancel the drying function
Operator
Table 8: Messages and instructions
8.3
Acknowledge message
1. Eliminate the cause of the error.
2.
-Press the key for approx. 2 seconds. Message disappears.
8.4
Error messages
This section describes possible faults and troubleshooting measures.
Contact the installer or dealer for your sauna system in the event of faults that cannot
be dealt with based on the following descriptions. Refer to the invoice, delivery note or