Technical Data
Installation instructions Sauna control Series FCU2x00/FCU3x00/FCU4x00 / Version V 2.18
9
2 Technical Data
2.1
Cables
Use of
inappropriate
cables –
Electric
potential
DANGER!
Danger to life due to electric potential
Use of inappropriate cables can lead to short circuits and subsequent
fires.
Damage to the insulation can be dangerous to life.
Therefore:
– All the cables, which lead to the sauna, must be designed for at least
150 °C.
– Use cables as per specifications in Table 1 and electrical circuit
diagram (see annexure). The specified cross sections are designed
for copper cables. In case of aluminum cables the cross sections
should be appropriately increased.
– The cross sections can increase due to the length of the cables, the
type of cable laying or special regulations.
Designation
Type
FCU2x00
FCU3x00
FCU4x00
Power supply cables
Type / Cross
section /
Number of
leads
H07RN-FG2,5 (heavy rubber hose 2,5 mm
2
)
Power supply cables must be polychloroprene-coated and
should not be lighter than heavy polychloroprene-coated
flexible cables.
Type
Heat resistant, at least 150 °C
230 / 400V cables for
supply to oven,
evaporator, fan, light etc.
Cross section
Number of
leads
→
See electrical circuit diagram.
Type
In case of longer distances: LiYCY
(flexible, shielded cable)
Within the cabin: heat resistant,
minimum 150 °C
Signal cables for sensors
Cross section
Number of
leads
→
See electrical circuit diagram.
Connecting cable
Control device to
operating element or
interior display
The patch cable can be delivered with a standard length of 5 or 10m.
If
another length is desired then the cable must be configured by the
electrician
. Another option would be to bridge a stretch by installing two
network sockets (CAT 5).
Specification of the patch
cable
Minimum CAT 5, minimum AWG26
Plugs should have no rubber covering over the locking mechanism
Pin 1 to Pin 1 cable configuration (straight through)
Conduit for patch cable
Min. M32 (inner diameter min. 24mm), smallest bending radius 30 cm
Table 1: Technical data – cables
Summary of Contents for FCU2000 Series
Page 38: ...Notes 38 Installation instructions Sauna control Series FCU2x00 FCU3x00 FCU4x00 Version V 2 18...
Page 39: ...Notes Installation instructions Sauna control Series FCU2x00 FCU3x00 FCU4x00 Version V 2 18 39...
Page 40: ...Address of the contractor installer or the dealer of the sauna unit...