The controller can be controlled / configured via the 5-key keypad or the
5 button radio control.
Keyboard :
SW1
key: starts the motor, allow s the ac-
cess to the Configuration menu and is used as
a key of confirmation in the Configuration
Menu.
SW2
key: turns off the motor, resets the
filters usage counter and filters alarm and is
used as a "Exit" key in the navigation within
the Configuration Menu.
SW3
key: increases the speed of the motor, allow s navigation
within the Configuration menu and allows you to enable/disable the auto-
matic operation.
SW4
key: increases the speed of the motor and allow s navigation
within the Configuration Menu.
SW5
key: turn on and turn off the light.
Radio:
Central key “
O
”: turn off / on the motor, reset the filters usage counter
and filters alarm and is used as a "Exit" key in the navigation within the
Configuration Menu.
“
MENU
” key: ("F" letter and watch in silkscreen): is used
to access the Configuration menu and as key Confirmation
in navigation in the Configuration menu.
“
+
” key: same function of SW3 key.
“
-
” key: same function of SW4 key.
“
Light
” key: same function of SW5 key.
8-segment display
Provides information about regulator operating status, in particular:
Motor speed;
possible alarms;
level menu and configuration values within the Configuration
Menu.
The display dot gives additional indications:
when it is fixed, it indicates that you are in the Configuration menu
and, during Startup, indicates the time to associate a new radio
control;
when it's flashing, it indicates a transient phase of operation:
starting speed, waiting time for opening Solenoid valve Gas, wait-
ing time shutting the motor off.
Led
The state of gas solenoid valve function is indicated by the LED on.
Management of the suction motor, solenoid valve gas and lights
The motor can operate in manual mode according 8 preset speeds con-
trolled by keyboard or by radio control.
In the transition from one speed to another, as well as switching on or
off, the motor always follows a suitable ramp.
Startup motor procedure
Pressing SW1 key or pressing "O", the motor starts for 3 seconds at the
starting speed (programmable) and then automatically switches to speed
1. After the interval set (see related configuration mode) it is enabled the
gas solenoid valve, the
DL
led is on. The point of the display flashes up
to
DL
led is on; in this time interval it is possible to change the speed of
the motor.
Shutdown motor procedure
Pressing the SW2 keyboard or pressing "O" of the radio control, the gas
solenoid valve is immediately turned off and the
DL
led switches off:
maximum speed motor is setted (speed 8) for setted time (see related
configuration mode) and then it stops. During the transitional phase
leading to the actual motor shutdown, the point of display flashes and
you can manually change the speed.
Motor management
With motor running, you can:
- Increase the motor speed (V1
V2
...
V7
V8) using the key SW3 on
the keyboard or "+" of the radio control;
- Decrease the motor speed (V8
V7
...
V2
V1) using the key SW4 on
the keyboard or "-" of the radio control.
- You can’t switch on the motor with the “+” command and you can’t turn off
the motor with the “-” command.
Light management
At any time and in any operating condition, you can turn on or turn off the
light through the key SW5 on the keyboard or "Light" of the radio control.
Reset filters alarm
The pressure, when motor is Off and not under Setting, for about three sec-
onds of the "STOP" button (or "START / STOP" of the radio control) resets the
counter of the hours of use of filters and any filters alarm.
Coupling new radio control
Cut power supply to the regulator and power on it again; press and hold the
"+" button of the remote control in the startup phase indicated by the point of
the display on; to indicate that coupling is ok, the letter “r” will be temporarily
displayed.
Note: You can’t associate more than one radio remote contol at a time;
if you attach a new remote control, the one, previously stored, will be re-
placed.
Restoring default settings
To restore the regulator default configuration, go into the Configuration Menu
(in terms of top-level menu), press and hold for 3 seconds the SW3 and SW4
keys; the exit from the configuration menu and the contextual temporary dis-
play of the letter "d" indicate the restoring.
This operation involves the restoring of default conditions for:
8 speeds in non-automatic operating mode
the starting speed
delay activation of gas solenoid valve when motor is on
delay of motor switching off
the hours of filter saturation (alarm disabled)
Attention:
default parameters restoring
can’t be made via radio con-
trol.
REGULATOR CONFIGURATION
Configuration Menu
With Motor off, access the Configuration Menu by pressing for at least 3 sec-
onds the button "SW1" or the "MENU" button of the radio control.
The keys of keyboard and Radio allow navigation in the Configuration menu
as follows:
-
SW1
or "
MENU
" (called "
ENTER
" ): Confirmation value set, or input
into submenus.
-
SW2
or "
O
" (referred to as "
ESC
" ): Exit w ithout saving value set, or
rising the tree submenus.
-
SW3
or "
+
" (referred to as "
UP
"): Increase value during setting or scroll of
sub menu items active.
-
SW4
or "
-
" (referred to as "
DOWN
"): Decrease value during setting or scroll
of sub menu items active.
"
P
"
menu
: The menu "
P
" is the entry point into the setup menu and allow s the
setting along the start speed, minimum and maximum;
UP
button switches to the "
T
"
menu while the
DOWN
button switches over to "
n
" menu.
With
ESC
key, you exit the Configuration Menu.
With
ENTER
key, you enter the sub-menu of the starting speed setting "
b
" (boost). The
motor runs at minimum speed that can be associated to that parameter (note that this
speed, depending on the type of load applied, it may not be sufficient to start the motor,
in this case, press the
UP
key to increase it up when the motor starts). The speed can be
adjusted to the desired point with the
UP
and
DOWN
keys.
With the
ENTER
key it is acquired as starting speed the current one and enter
the sub-menu setting of the minimum speed "
L
" (Low); using the
UP
and
DOWN
keys,
you can bring the motor speed to the minimum level required; you can’t select a speed
higher than that chosen for the starting speed.
With the
ENTER
key is taken as the minimum speed (1) the current one and enter the
sub-menu setting of the maximum speed "
H
" (High); the motor runs at maximum speed
(8) which can be varied to the desired point with the
UP
and
DOWN
keys.
With the
ENTER
key is taken as the maximum speed (8) the current one, intermediate
speeds are calculated automatically; the 8 speeds and the starting speed are stored and
you return to the "
P
" menu.
Pressing the
ESC
key in the submenu "
b
", "
L
" and "
H
" to return to the "
P
" menu
without saving any speed setting.
Menu "t"
: menu "
t
" allow s you to set the delay of the actual motor shutdow n
(see how to power off the motor);
UP
button switches to the "
F
" menu while the
DOWN
button switches to the "
P
" menu.
Press
ESC
key to exit from Configuration Menu.
With
ENTER
key, you enter the sub-menu of switch-off delay setting; using the
UP
and
DOWN
keys you can choose upon 10 possibilities (0 to 9) w hich correspond to
the timing in the following table:
0: 0 sec. 1: 20 sec. (default)
2: 40sec.
3: 60 sec.
4: 80 sec.
5: 100 sec.
6: 120 sec.
7: 140 sec.
8: 160 sec.
9: 180 sec.
Menu "F":
the menu "
F
" allow s you to set the hours of motor’s operation before
generating an alarm for saturation filters;
UP
button switches to the "
E
" menu while the
DOWN
button sw itches to the "
t
" menu. P ress
ESC
key to exit from
Configuration Menu.
With
ENTER
key, you enter the sub-menu of saturation’s hours setting; using the
UP
and
DOWN
keys,
you can choose upon 10 possibilities (0 to 9) w hich correspond to
the timing in the following table:
0:0 ore (Default – alarm OFF) 1: 10 ore
2: 20 ore
3: 30 ore
4: 40 ore
5: 50 ore
6: 60 ore
7: 70 ore
8: 80 ore
9: 90 ore
With the
ENTER
key, are captured and stored the life’s filters hours and returns to the
"
F
" menu.
Press
ESC
key to return to the "
F
" menu without saving the setting in progress.
Menu "E":
menu "
E
" allow s to set the activation delay of the gas solenoid valve
when the motor starts (see Startup motor Procedure); with the
UP
button you switch to
the "
A
" menu while with the
DOWN
button you switch to the "
F
" menu.
Press
ESC
key to exit from Configuration Menu.
With the
ENTER
key, you enter the sub-menu of setting the activation delay gas solenoid
valve; using the
UP
and
DOWN
keys, you can choose upon 10 possibilities (from 0 to 9)
which correspond to the timing in the following
table:
0: 1 sec.
1: 10 sec.
2: 20 sec. (default)
3: 30 sec.
4: 40 sec.
5: 50 sec.
6: 60 sec.
7: 70 sec.
8: 80 sec.
9: 90 sec.
With the
ENTER
key, is acquired and stored the selected delay and returns to the "
E
"
menu.
Press
ESC
key to return to the "
E
" menu without saving the setting in progress.