background image

FASAR ELETTRONICA S.r.L. 

Strada della Marina, 9/6 , 60019 Senigallia (AN) 

071.6609805 - [email protected] - www.fasar.it 

FE230/TI  -  Digital  speed  regulator  for  single-phase 

induction motors with temperature probe  

The FE230/TI module is an advanced electronic control 

system with microprocessor dedicated to the manual or 

automatic speed regulation of a single phase     induc-

tion  motor  (typically  intended  for  applications  of  air 

suction), to the management of the lighting system and 

a solenoid for the gas supply (or other type of load such 

as, for example, an external solenoid for the chimney’s 

opening).  The  accuracy  and  the  practicality  of  use  are 

guaranteed  by  the  use  of  a  last  generation  micropro-

cessor and by digital commands on the front panel. This 

model can work both in manual or automatic mode. The 

instructions below explain its functioning.  

Technical features 

 

 

Single-phase power supply: 85-265 Vac 50Hz. 

 

Fuse: 10AT. 

 

Stand-by power consumption (loads off): 0.35 W. 

 

Phase control with triac: speed motor setting and switch with relay.   

 

Type of motor: single-phase induction. 

 

Maximum load MOTOR: 4,5A. 

 

Maximum load LIGHTS: 2A. 

 

Features for gas solenoid valve: 230 Vac 50Hz MAX. 1A. 

 

Automatic mode management via NTC temperature probe.  

 

Digital input, as an alternative to the NTC temperature probe, to control a thermal con-

tact (normally closed) for the protection of the motor windings.  

 

Digital control settings with 5-key keypad, 1 LED and 1 7-segment LED digit display. 

 

IP protection: IP56. 

 

Dimensions: 158x118x77 mm. 

 

Weight: 0.37 kg. 

 

Technical features  

 

The regulator can be controlled/configured via the 5-key keypad.  

Keyboard: 

SW1 

key

: motor starts running, allow s the acces to the configuration menu and it is 

used as confirm key when navigating the configuration menu. 

SW2 

key

: torn off the motor, reset the filter usage counter 

and the filter alarm and it is used as the "Exit" button when navi-

gating the configuration menu. 

SW3 

key

: increases the speed of the motor, allow s naviga-

tion in the Configuration Menu and allows to enable / disable the 

Automatic   operation.  

SW4 

key

: decreases the motor speed and allow s naviga-

tion within the Configuration Menu.  

SW5

 

key:

 turn on/off the light. 

 

8-segments display 

It provides indications on the operating status of the regulator and in particular: 

 

speed implemented by the motor 

 

any automatic mode active  

 

any alarms in progress  

 

Menu level and configuration values in the Configuration Menu. 

 

The display point gives additional indications:  

 

when it is fixed it indicates that it is inside the Configuration Menu;  

 

when it is flashing it indicates a phase of transitory operation: accelleration, waiting time 

to open the gas solenoid valve, waiting time for the motor turning off.  

 

Led 

The status of activated Gas Solenoid Valve is indicated by the illiminated LED. 

 

Management of the suction motor, the gas solenoid valve and the lights  

The motor can operate in:  

 

Manual mode

, 8 preset speeds controlled by Keypad. 

 

Automatic  mode

,  with  the  supplied  NTC  temperature  probe  connected,  to  automatically 

adjust the motor speed according to the temperature detected by the   probe. Instaed of 

the  NTC  temperature  probe  it  is  possible  to  manage  a  digital  input  for  the  control  of  a 

thermal contact (normally closed) typically destined to the protection of the motor     win-

dings: for further information related to the Automatic Mode and to the logic of    opera-

tion of the aforementioned digital input, refer to the dedicated paragraphs.  

 

In the transition from one speed to the other, as well as at switch-on and switch-off, the mo-

tor always follows an appropriate ramp. 

 

Motor start procedure 

When the ignition command is given (SW1 key) the motor starts for 3 seconds at the           

acceleration speed (settable) and then automatically switches to speed 1. 

Once the set time has elapsed (see the relative configuration mode), the Gas Solenoid valve 

is activated with the relative lighting of the 

DL

 LED.  

 

Motor shutdown procedure  

At the shutdown command (SW2 key), the gas solenoid valve is immediately deactivated and 

this event is signaled by the 

DL

 LED: the motor starts to suck at maximum power (speed 8) 

for the set time (see relative configuration mode), after which it stops. During the transitory 

phase that leads to the actual switching off of the engine, the Display Point flashes and the 

speed can be changed manually. 

 

 

Motor management 

With the engine running it is possible to: 

- Increase the motor speed in sequence (V1 - V2 - ... - V7 - V8) using the SW3 key on the key-

board; 

- Decrease the motor speed in sequence (V8 - V7 - ... - V2 - V1) using the SW4 key on the key-

board.  

It is not possible to start the engine with the Speed Increment command and the engine can not 

be switched off with the Speed Decrease command.  

 

Light Management

 

At any time and in any operating condition the light can be switched on or off using the SW5 

key on the keyboard.  

 

 

Automatic operation  

 

When  an  NTC  temperature  probe  is  connected  to  the digital  controller,  it  is possible  to enable 

the Automatic Mode to obtain an automatic and linear adjustment of the motor speed according 

to the temperature measured by the NTC probe . 

The  Automatic  Mode  is  activated  and  deactivated  alternately  keeping  the  SW3  key  of  the      

keyboard pressed for about 2 seconds when the motor is off and not in the configuration menu. 

The  activation  of  the  Automatic  Mode  is  signaled  by  the  temporary  display  of  the  letter  "A";  

while the deactivation of the Automatic Mode (ie the return to Manual Mode) is signaled by the 

temporary display of the number "0".  

In Automatic Mode, the speed varies between the minimum and the maximum speed set for non

-automatic operation: the latter are controlled at settable temperature limits.  

The Automatic Mode is active with the motor running, if the regulator is not in the condition of: 

- configuration via Menu; 

- initial acceleration; 

- motor shutdown delay.  

The automatism does not control the ON and OFF of the motor-driven fan, but, if activated,  

regulates its speed. 

 

The automatic operation of the fan is indicated by the letter "A" which alternates with the     

indication of the non-automatic speed closest to the current one. 

 

To optimize the automatic operation according to the probe position and the size of the        

extractor hood, it is possible to set from the menu the two temperature limits corresponding to 

the minimum and maximum engine speeds (see the paragraph dedicated to the Configuration 

Menu); for intermediate temperatures an intermediate speed is implemented. 

 

Management of a thermal contact for the protection of the motor windings  

 

As an alternative to the NTC temperature probe it is possible to manage a digital input for the 

control of a thermal contact (normally closed) typically intended for the protection of the motor 

windings. If this configuration is used, the 

Manual Motor Speed Adjustment Mode

 must  

always

 

be selected. 

As  long  as  the  thermal  contact  is  closed,  all  the  functions  of  the  digital  controller  can  be       

managed:  

 

turn the engine on/off and increase/decrease the speed by pressing the appropriate keys on 

the keyboard; 

 

turn on/off the light;  

 

access the configuration menu and reset the filter counter.  

When the contact opens, any loads that are switched on are switched off and the display shows 

the  indication  "c"  flashing;  if,  before  the  power  supply  to  the  regulator  is  disconnected,  the   

thermal contact closes, the functions that were active before the event of opening the contact 

are restored (unless the engine shut-off keys have been pressed in the meantime) and/or light).  

As long as the thermal contact is open, it is only possible to access the configuration menu and 

reset the filter counter: any attempts to switch on the engine and / or light have no effect.  

Note: 

w ith the thermal contact open and in the presence of an eventual filter alarm, 

the display alternately shows the letter "c" and the letter "F" indicating active filter alarm.  

 

Visualization and management of alarm conditions  

when the NTC temperature probe is connected to the controller  

 

In critical  operating  conditions  (for  example,  when  the Automatic  Mode  is  active or  if  the  NTC 

probe wiring may be damaged), the digital controller signals an alarm condition; in particular:  

1) if the NTC temperature probe is not detected (possible damage to the wiring) or if it returns 

temperature  measurements  below  the  minimum  permissible  limit,  the  display  will  show  the  

letter "c" flashing and possibly alternating with other indications such as specified below;  

2) if the NTC temperature probe returns temperature measurements above the maximum    

permissible limit, the display will show the letter "E" flashing and possibly alternating with other 

indications as specified below.  

If  the  alarm  condition  occurs  with  the  Automatic  Mode  activated,  the  automation  remains  

inhibited until the correct functioning of the probe is restored and:  

 

if the anomaly occurs with the motor running, then the maximum speed set for the    motor 

is activated and the display shows an alarm code (represented by the letter "c" or the letter 

"E", as specified above) alternating with the indication of the current speed; in this situation 

it  is  always  possible,  by  pressing  the  appropriate  keys  on  the  keypad,  to  set  a  different 

speed of the motor as well as switch off/on the light and the motor; 

 

when the motor is switched off, a flashing alarm code appears on the display (represented 

by the letter "c" or the letter "E", as specified above); in this situation it is always possible, 

by pressing the appropriate keys on the keyboard, to switch on / off the light and the motor 

and, if necessary, set the desired speed; 

 

if the anomaly is signaled by the letter "E" you can deselect the Automatic Mode (by pres-

sing for about 2 seconds the SW3 key of the keyboard, as already specified above) in order 

to  use  the  controller  according  to  the  Manual  Mode  without  having  any  alarm  signal  to  di-

splay; 

 

if the anomaly is signaled by the letter "c" the controller can not be used by deselecting the 

Automatic Mode: in fact, if in this situation the SW3 key of the keyboard is pressed for about 

2 seconds to activate the Manual Mode, the display shows the letter "C"      flashing and the 

light and motor ignition commands are ignored.  

 

The manufacturer declares that this product is free from manufacturing defects. 

 

The guarantee lasts 12 months if the product is correctly used. 

 

The manufacturer reserves the right to make changes, also without     notice, on 

the device or on the documentation in order to improve its  performances.  

WARNINGS: 

 

B

efore installing and plugging the device into the mains, check the integrity of the 

appliance, check that the specifications indicated on the data plate and the tech-
nical characteristics explained on this manual correspond to those of the electrical 
mains system, of motor, of lighting system and of eventual gas solenoid valve. 

 

A

lways  use  high  quality  and  suitable  section  electric  cables  wire  to  connect  the 

regulator to the mains and to loads.   

 

D

uring the installation of the appliance, pay particular attention not to damage the 

sheath of the power cable. 

 

I

f  the  power  cable  (not  supplied)  is  damaged,  it  must be replaced by  authorized 

personnel, using an equal or better quality cable. 

 

We  recommend  that  you  keep  within  the  device  the  lenghts  cable  short  to  avoid 
their contact with particular components that could reach high temperatures. 

 

I

t  is  advised  to  use  cable  glands  (at  least  IP55  or  IP68)  or  suitable  fittings  that 

have enough space for the cables to exit but avoid seepage of moisture and con-
densation. 

 

I

nstall the regulator in ventilated places and away from sources of heat, especially 

if the current load absorption are close to the maximum declared. 

 

Be sure to connect the ground wire of the motors (or the chassis of the motors) to 
the main board and the latter one to the grounding system of the network. 

 

T

o avoid danger of fire, electric shock or malfunctions, do not expose the device to 

rain, humidity, favouring the installation in a dry place. 

I

t is recommended to not 

install the regulator in areas with moisture, fumes or gas, avoid direct sunlight or 
heat sources that could damage the device dissipation capacity.        

 

T

he regulator must be installed and used only in compliance with the instructions 

provided:  the  manufacturer won’t be responsible for  the  improper  use of  the  de-
vice (if it is used for applications different than those for which it was designed) or 
for failure to comply with these warnings.  

 

T

he  appliance  can  be  used  by  children  under  8  years  of  age  and  by  people  with 

reduced  physical,  sensory or mental  abilities,  or without  experience  or  necessary 
knowledge, provided that they are under surveillance or after they have received 
instructions relating to the safe use of the appliance and an understanding of the 
dangers  inherent  in  it. 

C

hildren  must  not  play  with  the  appliance. 

C

leaning  and 

maintenance  intended  to  be  carried  out  by  the  user  must  not  be  carried  out  by 
children without supervision.  

 

B

efore  carrying  out  any  maintenance  or  cleaning  operation,  make  sure  that  you 

have disconnected the appliance from the power supply. 

 

I

n case of failure or malfunction, turn off the appliance, disconnect the power sup-

ply and call the manufacturer. 

Reviews: